Endress+Hauser TMT162 Temperature Field Transmitter

Description

Overview

The Endress+Hauser TMT162 is a dual-input, head-mounted universal temperature transmitter engineered to accept virtually any temperature sensor signal – resistance thermometers (RTD), thermocouples (TC), resistance transmitters (Ω), or millivolt (mV) signals – and convert it into a stable, digitally communicable output over HART®, FOUNDATION Fieldbus™, or PROFIBUS® PA. Built into Endress+Hauser’s iTEMP family, the TMT162 is designed for plant engineers who need one transmitter platform that can be configured on-site for whichever sensor type a process actually uses, reducing the spare-parts inventory and engineering time associated with carrying multiple single-purpose transmitters.

Working closely with plant engineers in the region, Seven Star LLC proudly supplies the TMT162 temperature transmitter to refineries, petrochemical plants, desalination facilities, and process industries across the Sultanate of Oman and the wider GCC. Every unit we supply is sourced on request, with manufacturer documentation and local technical support.

Measurement Principle

The Endress+Hauser TMT162 operates as a universal signal conditioner rather than a sensor itself: it accepts the raw resistance, voltage, or millivolt signal generated by a connected RTD, thermocouple, or resistance/voltage transmitter, linearizes it against the appropriate characteristic curve, and outputs a clean, temperature-proportional 4-20 mA HART signal or a digital FOUNDATION Fieldbus/PROFIBUS PA value. Two independent input channels allow a second sensor to be wired in as a redundant backup, a differential measurement, or a completely separate measuring point, with the transmitter’s onboard diagnostics continuously monitoring both channels for open-circuit, short-circuit, sensor drift, and corrosion at the sensor terminals.

Because the Endress+Hauser TMT162 performs signal conditioning digitally inside a fully potted electronics module, the practical result for the plant is a transmitter that is largely immune to vibration and moisture ingress, delivers galvanic isolation of 2 kV between the sensor input and the output loop, and reports NAMUR NE107-compliant diagnostic status so operators can distinguish a genuine process alarm from a sensor fault without a site visit.

Engineering Design of the Endress+Hauser TMT162

The Endress+Hauser TMT162 is housed in a dual-compartment field enclosure available in aluminum or optional stainless steel for hygienic or heavily corrosive environments, with a separate compartment for the terminal block and the electronics so that field wiring can be carried out without exposing the transmitter core. A large backlit local display shows the measured value, a bar graph, and unit/status indication, and the entire configuration – sensor type, range, alarm levels, damping – can be set locally via the display keys or remotely via a HART handheld communicator or asset management software without opening the enclosure.

The transmitter mounts directly onto a DIN Form B (TA) connection head on the sensor assembly, onto a standard 2-inch pipe using an optional mounting bracket, or into a control cabinet as a rail-mounted variant, giving instrumentation designers flexibility across new installations and retrofits of existing thermowell assemblies. Approvals for ATEX (Ex ia, Ex nA nL, Ex d), FM, and CSA (IS, NI, XP, DIP) intrinsically safe and explosion-proof variants mean the same transmitter platform can be specified across both safe-area and hazardous-area process units on a single site.

Key Features

The Endress+Hauser TMT162 combines broad sensor compatibility with the diagnostic depth plant engineers expect from a modern process transmitter, and the Endress+Hauser TMT162 feature set below reflects that breadth. Key features include:

  • Universal dual-channel input accepting RTD, thermocouple, resistance transmitter, and mV signals from a single hardware platform.
  • Selectable digital communication over HART, FOUNDATION Fieldbus H1, or PROFIBUS PA (Profile 3.02) to match the plant’s existing control system.
  • Accuracy of ±0.1 K for Pt100 RTD inputs, suitable for tightly controlled process temperature loops.
  • Backlit local display with measured value, bar graph, and diagnostic status for quick field verification.
  • Sensor backup and automatic switchover between the two input channels on primary sensor failure.
  • Drift alarm and corrosion detection at the sensor terminals for early warning of degrading RTD or thermocouple connections.
  • SIL 2 certification per IEC 61508:2010 for use in safety instrumented functions.
  • ATEX, FM, and CSA hazardous-area approvals plus marine approval for offshore and marine process applications.

Industrial Applications

The Endress+Hauser TMT162 is deployed wherever a plant needs dependable, sensor-agnostic temperature measurement on process lines, reactors, storage tanks, and rotating equipment bearings. In Oman’s oil and gas sector, it is commonly specified on wellhead skids, gas processing trains, and pipeline metering stations where hazardous-area certification and HART compatibility with existing asset management systems are mandatory. In desalination and district cooling plants across Muscat, Sohar, and Salalah, the TMT162’s dual-input capability lets a single transmitter monitor both a primary RTD and a redundant backup sensor on critical heat-exchanger and chiller loops, reducing unplanned downtime from a single sensor failure.

With fast quotation turnaround and technical support, Seven Star LLC distributes the TMT162 to EPC contractors and plant operators across the Sohar and Salalah economic zones, as well as to pharmaceutical, food and beverage, and power generation facilities throughout the GCC that require SIL 2-rated temperature transmitters with full documentation and factory traceability. Its stainless steel housing option also makes it a common choice for hygienic process skids in the region’s growing food and pharmaceutical manufacturing base.

Technical Specifications

Key technical parameters of the Endress+Hauser TMT162 temperature field transmitter, the Endress+Hauser TMT162, are summarized below.

Parameter Specification
Model Endress+Hauser TMT162
Inputs 2 × RTD, thermocouple (TC), resistance (Ω), or mV
Communication HART (4-20 mA), FOUNDATION Fieldbus H1, PROFIBUS PA (Profile 3.02)
Accuracy (Pt100) ±0.1 K (HART, FF, PA)
Galvanic isolation 2 kV between sensor input and output
Housing material Aluminum (standard) or stainless steel (hygienic/Ex d option)
Display Backlit local display with measured value, bar graph, and status
Safety rating SIL 2 per IEC 61508:2010
Hazardous-area approvals ATEX (Ex ia, Ex nA nL, Ex d), FM, CSA (IS, NI, XP, DIP)
Diagnostics NAMUR NE107, sensor backup, drift alarm, corrosion detection
Mounting DIN Form B connection head, 2-inch pipe bracket, or rail-mount

Request a Quote for Endress+Hauser TMT162

Facility engineers and procurement teams in Oman and the GCC can request a formal quotation for the Endress+Hauser TMT162 temperature field transmitter directly from Seven Star LLC. The Endress+Hauser TMT162 can be sourced on request for urgent replacement orders, with lead time confirmed at quotation. We supply TMT162 units and accessories on request, and our instrumentation division can provide the full technical datasheet, wiring diagrams, and hazardous-area certification documentation to support your project’s engineering package. With engineering support in Muscat, Seven Star LLC is your single point of contact for TMT162 transmitters and technical support across the region.

Browse the full Endress+Hauser (E & H) range or see more Temperature Instrumentation products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser TMT162 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser TMT162 Temperature Field Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What makes the Endress+Hauser TMT162 different from a standard single-input transmitter?
The TMT162 accepts two independent sensor inputs of virtually any type (RTD, thermocouple, resistance, or mV) on one hardware platform, and can use the second input as a redundant backup sensor, cutting spare-parts inventory and enabling automatic switchover on sensor failure.
02What communication protocols does the TMT162 support?
The TMT162 is available with HART over 4-20 mA, FOUNDATION Fieldbus H1, or PROFIBUS PA (Profile 3.02), so it can be integrated into most existing DCS or asset management architectures without additional gateways.
03Is the TMT162 suitable for hazardous-area installations?
Yes. It is available with ATEX (Ex ia, Ex nA nL, Ex d), FM, and CSA (IS, NI, XP, DIP) approvals, along with SIL 2 certification per IEC 61508:2010, making it suitable for both intrinsically safe and explosion-proof zones as well as safety instrumented functions.
04Can the TMT162 be integrated with legacy analog control systems?
Yes, the HART variant outputs a standard 4-20 mA analog signal superimposed with the HART digital protocol, so it can be wired directly into legacy analog input cards while still allowing digital configuration and diagnostics via a HART communicator.
05Is Seven Star LLC an experienced supply partner for Endress+Hauser products?
Yes, Seven Star LLC supplies Endress+Hauser (E & H) products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.