Brand: Endress+Hauser (E & H)
Endress+Hauser TMT36 iTEMP IO-Link Head Transmitter
Description
Endress+Hauser TMT36 iTEMP IO-Link head transmitter
The Endress+Hauser TMT36 is an iTEMP single-channel head transmitter with an IO-Link interface. It fits into a form B (flat-face) terminal head to DIN EN 50446 and converts one RTD input into digital IO-Link data, so that a sensor on a machine or skid reaches the PLC through a standard IO-Link master with no analogue card. The TMT36 can be installed in modular thermometers of the Endress+Hauser range to digitalise measuring points that need IO-Link, and it applies Callendar-Van Dusen sensor-transmitter matching to improve accuracy. Seven Star LLC supplies the TMT36 in Oman and the GCC as an independent supplier in Muscat.
TMT36 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / iTEMP TMT36 |
| Input | 1 x RTD (Pt100, Pt1000); 2-, 3-, 4-wire |
| Accuracy | 0.15 K or better over the entire range |
| Output | IO-Link or one PNP/NPN/push-pull switch output (C/Q) |
| Switching capacity | 150 mA or less |
| Supply | 18 to 30 V DC; current consumption 11 mA |
| Mounting | Terminal head form B (DIN EN 50446) |
| Matching | Callendar-Van Dusen |
| Galvanic isolation | No |
| Certification | CSA General Purpose |
Input and accuracy of the TMT36
The input is one RTD, Pt100 or Pt1000, in 2-, 3- or 4-wire connection with a sensor current of 0.3 mA or less. In the 2-wire circuit, wire resistance of 0 to 30 Ω can be compensated, and with 3- or 4-wire connection the lead resistance can be up to 50 Ω per wire. Accuracy for Pt100 and Pt1000 over the entire range is 0.15 K or better. The transmitter has no galvanic isolation between input and output.
Output and IO-Link data
The output is the C/Q line: either IO-Link communication or one configurable switch output (PNP, NPN or push-pull) with switching capacity up to 150 mA, with automatic overload protection and a diagnostic message when overloaded. The fault state of the switch output can be set to on, off or high-impedance. The device is an IO-Link Smart Sensor with one measuring and switching channel, and it stores parameters so that a replaced device can be restored automatically from the master. The display of the three highest-priority diagnostic messages helps service staff.
Electrical data and approvals
Supply voltage is 18 to 30 V DC with a current consumption of 11 mA, and the ambient temperature range is −40 to +85 °C according to the label. The documented certification is CSA General Purpose. There is no explosion-protection approval stated in the page data, so the TMT36 is for safe-area use unless the order code indicates otherwise.
Selecting the TMT36
Match the sensor (Pt100 or Pt1000) and the number of wires to the insert in your thermometer, and check that the IO-Link master port is class A and that the master supports the data size of the TMT36. If you need 4 to 20 mA or HART, choose another iTEMP transmitter such as the TMT82 or TMT72 instead.
Installing and commissioning the TMT36
Fit the transmitter into the head on the spring-loaded screws so that the sensor wires land on the push-in or screw terminals and the head cover seals. Connect the M12 cable from the master to the head terminals, assign the IO-Link port and load the parameter set. The measured value and diagnostics then appear in the PLC process image; scale and range limits can be set through IO-Link tools.
TMT36 in Oman and GCC plants
The transmitter is aimed at skids, machines and packaged plant which already use IO-Link, such as filling lines, water-treatment skids and utility modules, where it reduces cabinet hardware and wiring cost. Its use in large-scale oil and gas plant is limited because there it needs HART or fieldbus and an Ex approval.
TMT36 within the iTEMP range
| Model | Interface |
|---|---|
| TMT36 | IO-Link, single RTD |
| TMT71 | 4 to 20 mA analogue |
| TMT72 | HART |
| TMT84 / TMT85 | PROFIBUS PA / FOUNDATION Fieldbus |
Information to send with a TMT36 RFQ
- Sensor type and wiring
- Head type and thermometer model
- Master and PLC platform
- Range and switching function
- Quantity and delivery location
Diagnostics, replacement and spares for the TMT36
The TMT36 reports sensor and device faults over IO-Link as event messages, so the PLC can show a wire break, a short circuit or an out-of-range reading with the channel name. When a unit is replaced, a master with data storage can write the old parameter set into the new device automatically, which keeps the change-over to a few minutes and does not need a laptop on site.
For spares keep the same sensor type, wiring and IO-Link revision. Remember that the transmitter has no galvanic isolation, so ground loops between the sensor sheath and the machine frame can affect the reading; connect the insert as the manufacturer describes and avoid earthing the sensor on both sides. Check the push-in terminals after vibration on engines or compressors.
Mounting notes for the TMT36 in hot sites
In hot climates the ambient temperature inside a terminal head in direct sun can exceed the air temperature by a wide margin, so use a sunshade or a head with a neck extension on hot lines and respect the −40 to +85 °C range of the electronics.
Documents and quotation
A copy of the manufacturer technical information for the TMT36 is attached on this page so you can check ranges, connections and ordering codes against your specification.
Send the full order code or the process data (fluid, temperature, pressure, line size or tank data, output and approvals) and Seven Star LLC will prepare a quotation and confirm lead time. We are an independent supplier in Muscat and do not represent the manufacturer.
Datasheets & Documents
- Datasheet Endress+Hauser TMT36 Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser TMT36 iTEMP IO-Link Head Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What does the TMT36 do?
It converts one RTD input into digital IO-Link data, or a switch output, inside a form B terminal head.
02Which sensors can it use?
Pt100 and Pt1000 RTDs in 2-, 3- or 4-wire connection.
03How accurate is it?
0.15 K or better over the entire measuring range for Pt100 and Pt1000.
04Is it isolated?
No, there is no galvanic isolation between input and output.
05What supply does it need?
18 to 30 V DC with 11 mA current consumption.


















Reviews
There are no reviews yet.