Brand: JUMO
JUMO flowTRANS MAG H01 Hygienic Magnetic Flowmeter, 406015
Description
A HART magmeter with 0.2 % accuracy for hygienic and Ex-area lines
The JUMO flowTRANS MAG H01 (type 406015) is an electromagnetic flowmeter developed for the food and pharmaceutical industry, with an all-stainless-steel design that is FDA-compliant and easy to clean. Its PFA lining is vacuum-proof and dimensionally stable, and the sensor withstands CIP and SIP cleaning up to 150 °C. Compared with the simpler H10 series, the H01 offers a standard accuracy of 0.4 % of the measured value with a 0.2 % option, HART communication as standard with PROFIBUS-PA as an option, and compact or remote versions approved for ATEX and IECEx gas zones 1 and 2 and dust zones 21 and 22. The variable connection concept fits Tri-Clamp, dairy thread, weld stubs or wafer bodies to one standard sensor, which reduces spare parts stock.
Technical specifications
| Parameter | Specification |
|---|---|
| Model numbers | 406015/1-0 and 406015/1-1 compact; remote sensor 406015/2-0, 406015/2-1 with transmitter 406018/2-0, 406018/2-1 |
| Nominal width | DN 3 to DN 100 (1/10 to 4 in.) |
| Measuring deviation | Standard 0.4 % of measured value, option 0.2 % of measured value (DN 10 to 100), plus 0.02 % of QmaxDN |
| Repeatability | Up to 0.11 % of measured value at 0.5 to 10 m/s |
| Conductivity | Above 5 µS/cm; 20 µS/cm for demineralised water |
| Process connections | Wafer; DIN 11851 compression fitting; DIN 11850 welded socket; Tri-Clamp DIN 32676 and ASME BPE; PN 10 to PN 40 |
| Lining and electrodes | PFA, vacuum-proof; electrodes 1.4539 (904L) or Hastelloy C-4 or tantalum |
| Medium temperature | -25 to +130 °C with variable connections; flange version up to +180 °C; PFA lining usable at 0 mbar absolute up to 180 °C |
| Cleaning | Steam 150 °C and liquids 140 °C for up to 60 minutes at 25 °C ambient |
| Seals | EPDM (CIP-resistant) or silicone, to FDA 21 CFR 177 |
| Materials | Deep-drawn housing and terminal box in 1.4308; stainless steel meter tube; process connection 1.4404 |
| Supply | AC 100 to 230 V (-15/+10 %), AC 24 V (-30/+10 %) or DC 24 V (-30/+30 %) |
| Outputs | 4 to 20 mA active or passive; pulse active or passive; optocoupler switching output and input |
| Communication | HART standard; PROFIBUS-PA option |
| Display | Adjustable graphical display with non-contact operating buttons |
| Remote cable | 50 m without preamplifier, 200 m with preamplifier; 5 m supplied (00648906) |
| Ambient temperature | -20 to +60 °C; storage -40 to +70 °C |
| Protection | IP65 and IP67 (NEMA 4X); IP68 for remote sensors |
| Approvals | 2014/30/EU EMC; ATEX 2014/34/EU and IECEx options; PED 2014/68/EU category III fluid group 1 |
Housing, Ex options and electronics
The device exists in a single-compartment housing for non-Ex use and for zone 2, 21 and 22, and in a dual-compartment housing for zone 1, 21 and 22 on the compact design. The remote design is offered for zone 2. A SensorMemory in the sensor identifies it automatically, so the transmitter configures itself when voltage is applied and the sensor data and measuring-point parameters load without manual entry. Operation is by softkeys with a back-lit display that can be turned without tools, and an easy-setup function guides new users. Diagnostics include empty-pipe detection and sensor measurement, with NAMUR status classes and help texts, and limit values can be adjusted on site. A DTM supports further analysis of the diagnosis data, so critical states can be detected early and countermeasures taken before downtime occurs.
The universal transmitter module can deliver counting pulses, a 4 to 20 mA signal or a status output, each active or passive and selectable in software. The transmitter slot can be dismantled without unscrewing cables or removing connectors, which shortens a replacement. Electrical safety follows DIN EN 61010-1 and EMC follows DIN EN 61326-1 and 61326-2-3.
Selection and installation notes
Keep 10 x DN of straight pipe upstream and 5 x DN downstream and allow a 30 minute warm-up. If the ambient temperature exceeds 25 °C, subtract the difference from the cleaning temperature limit. When used in explosive atmospheres, observe the extra temperature tables for zone 1 and zone 2 in the datasheet. Wafer bodies allow 40 bar up to DN 50 and 16 bar for DN 65 to 100. The datasheet contains an order code for the compact design, the remote sensor and the remote transmitter. Scope of delivery for the compact design is the sensor and the transmitter as one unit, while the remote design lists sensor and transmitter as separate order codes. Typical duties are dairy, beverage, pharmaceutical water and chemical dosing, where a HART signal into the control system and a higher accuracy class justify this model.
Using the flowTRANS MAG H01 in Oman and the GCC
The H01 suits food, beverage and pharmaceutical plants where higher accuracy, HART communication or Ex approvals are needed, such as flavour and ingredient dosing, solvent lines and filling lines in hazardous areas. In the region, dairy, juice and bottled water producers, as well as pharmaceutical manufacturers, use this type of meter for batching and for monitoring CIP and SIP cycles.
For good results, keep the pipe full at the meter, observe the inlet and outlet runs in the operating manual and check that the cleaning temperatures stay within the stated limits. In Ex areas, the installation must follow the certificate and local rules. Keep the transmitter out of direct sun and away from hot steam lines, especially in summer.
Sending the existing line drawing helps us confirm the connection and the transmitter position before ordering.
Information to send with an enquiry
- Nominal size and process connection
- Product, flow range, temperature and cleaning conditions
- Compact or remote version, Ex approval and communication (HART or PROFIBUS-PA)
- Accuracy class required
- Quantity
Related JUMO products: JUMO flowTRANS MAG H20 Hygienic Electromagnetic Flowmeter, JUMO flowTRANS MAG S01 Electromagnetic Flowmeter, JUMO flowTRANS MAG I02 Insertion Electromagnetic Flowmeter, JUMO flowTRANS US W01 Ultrasonic Flowmeter for Liquids, JUMO flowTRANS MAG H10 Hygienic Magnetic Flowmeter, 406061 and JUMO flowTRANS MAG S10 Electromagnetic Flowmeter, Type 406060.
Documents and quotation
The hosted document is JUMO data sheet 406015 (50 pages, English). It carries order codes, dimensions and Ex temperature data. Confirm design, connection, accuracy class and Ex zone before ordering. Seven Star LLC is an independent supplier in Muscat; send the product, line size and area classification for a quotation. To help us prepare an accurate quotation, please include the process medium, operating pressure and temperature, nominal size, required output signal and supply voltage, together with the quantity needed and the delivery location. We will then compare these details with the order information in the datasheet.
Datasheets & Documents
- Datasheet JUMO 406015 data sheet 406015 (EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.
Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.
JUMO company profile
| Established | 1948, Fulda, Germany, by Moritz Kurt Juchheim |
|---|---|
| First products | Glass and contact thermometers; platinum glass sensors from 1966 |
| Ownership | Family-owned; renamed JUMO GmbH & Co. KG in 2003 |
| Product families | RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments |
Milestones
- 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
- 1966: Platinum glass temperature sensors are added.
- 2003: The parent company is renamed JUMO GmbH & Co. KG.
JUMO products we list
| Family | Models | Typical use |
|---|---|---|
| RTD and thermocouple probes | 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp | Temperature measurement in pipes, vessels, machines, HVAC and food plants |
| Thermowells and inserts | 909710 thermowells, 909740 measuring inserts | Protecting sensors and replacing them without opening the process |
| Temperature transmitters | dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch | Converting sensor signals to 4-20 mA, HART or IO-Link |
| Pressure and level | dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 | Pressure in process, hydraulic and OEM systems; tank and well level |
| Controllers, limiters and recorders | DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T | Furnace, oven and process control, over-temperature protection and recording |
| Liquid analysis and flow | AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 | pH, conductivity, oxygen and turbidity in water treatment; liquid flow |
Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.
Where JUMO products are used
In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.
Ordering JUMO products: what we need
Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.
Facts checked against JUMO's company history, October 2026.
Browse JUMO products by category: Temperature Instrumentation, Pressure Instrumentation, Liquid Analysis Sensors, Controllers & Data Acquisition, Level Transmitter.
FAQ
Questions about the JUMO flowTRANS MAG H01 Hygienic Magnetic Flowmeter,
Answers from our engineering team on installation, compatibility and integration.
01What accuracy does the MAG H01 offer?
Standard deviation is 0.4 % of measured value, with a 0.2 % optional calibration for DN 10 to DN 100.
02Which communication does it use?
HART is standard and PROFIBUS-PA is available as an option.
03Is an Ex version available?
Yes, ATEX and IECEx versions cover gas zones 1 and 2 and dust zones 21 and 22 depending on the design.
04How long can the remote signal cable be?
Up to 50 m without a preamplifier and up to 200 m with a preamplifier, with a 5 m cable supplied.
05Can it be steam sterilised?
CIP and SIP cleaning is allowed at up to 150 °C for steam and 140 °C for liquids, for at most 60 minutes.