Brand: Yokogawa
Yokogawa SC450G-D-A Conductivity Converter, 24 V DC
Description
DC-powered Yokogawa SC450G-D-A at a glance
Some process sites cannot offer mains power at the analyser, and for them Yokogawa SC450G-D-A exists. It is the DC-supplied general purpose build of the EXAxt 450 four-wire conductivity converter: same touchscreen, same measurement engine, same relay and HART capability as the AC unit, but powered from 12 to 24 V DC.
Think of it as the answer to a question about the cabinet rather than the sensor. If the plant has a 24 V DC distribution with battery backup, or the converter sits on a packaged water-treatment skid, SC450G-D-A removes the need for a separate mains cable.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What the SC450G-D-A suffix tells you
| Parameter | Value |
|---|---|
| D | DC version: 12 to 24 V DC rating, 10.8 to 26.4 V DC acceptable, 10 W |
| A (second) | General purpose type with IP66 cable glands supplied |
| Not included | FM nonincendive approval, which belongs to the U type |
| Options possible | /UM, /U, /PM, /H5, /AFTG, /ANSI, /AM20, /SCT |
Reading the code this way avoids ordering mistakes. A buyer who needs a 24 V DC unit and writes only SC450G on the enquiry could receive an AC unit, so the D matters.
Measurement capability
The input stage accepts two-electrode and four-electrode cells with cell constants from 0.005 up to 50.0 per cm and works with cable up to 60 m (200 ft) of WU40 or WF10. Conductivity is displayed from 0.000 uS/cm to 2000 mS/cm and resistivity up to 1000 Mohm-cm. Five temperature elements are supported for compensation: Pt1000 from -20 to 250 C, Pt100 and Ni100 from -20 to 200 C, NTC 8k55 from -10 to 120 C and Pb36 from -20 to 120 C. The reference temperature is programmable from 0 to 100 C, with 25 C as default.
Control, relays and signals
- Output function can be linear or a 21-step non-linear table for conductivity, resistivity, concentration or temperature.
- PID control may act on either the mA outputs or the contact outputs, and pulse frequency or pulse length control suits chemical metering pumps and solenoid valves.
- Contact S4 can be programmed as the fail-safe contact, and a contact input switches the programmed range to ten times its value remotely.
Typical applications for SC450G-D-A in Oman and the GCC
Typical homes are containerised reverse-osmosis skids at remote wells, boiler blowdown control panels driven from a 24 V DC PLC supply, and wash-water monitoring in utilities. In oil and gas facilities, 24 V DC from the UPS is the dependable supply on critical analyser shelters, and the DC converter plugs into that arrangement directly. Municipal desalination plants along the Batinah coast can use it for permeate and product-water monitoring.
SC450G-D-A technical data and how it differs from other SC450G variants
| Parameter | Value |
|---|---|
| Supply | 12 to 24 V DC rating, acceptable 10.8 to 26.4 V DC, 10 W maximum consumption |
| Display | Quarter VGA 320 x 240 pixels, LED backlight, touchscreen, 8 languages |
| Enclosure | IP66 / NEMA 4X / CSA Type 3S cast aluminium, 144 x 144 x approx. 144 mm |
| Weight | Approx. 1.5 kg |
| Outputs | 2 x 4-20 mA isolated, 600 ohm load, HART 5 on mA1; 4 x SPDT relays |
| Compensation | IEC 60746-3 NaCl default, temperature coefficient 0 to 3.5 percent per C, 13 + 2 matrices |
| Standards | EN 61010-1, EN 61326-1 Class A, RoHS EN 50581, installation category II, pollution degree 2 |
Compared with SC450G-A-A, the only electrical change is the supply: 10 W at 12 to 24 V DC instead of 15 VA at 100 to 240 V AC. Compared with SC450G-A-U, the housing is the same size and the measurement identical, but SC450G-D-A has no FM nonincendive listing and uses IP66 glands rather than NEMA 4X plugs. If a data sheet for your project requires T6 at 55 C ambient in Class I Division 2, SC450G-D-U is the code to ask about, not this one.
Another point of difference is power consumption in practice. At 10 W on a DC bus, the converter adds very little load to a battery-backed analyser cabinet, and no inverter is needed to feed it.
Selection and compatibility notes
Before ordering SC450G-D-A, list the sensor model, the cable length and the temperature element so the compatibility with the converter can be checked. The input accepts cell constants from 0.005 to 50 per cm, which covers ultra pure water cells, standard process cells and high-range cells, but the cell must be a conductivity cell with 2 or 4 electrodes and not an inductive toroidal sensor. For toroidal sensors a different converter is needed.
Also decide whether the awning hood, panel kit or conduit adapter is required, and mention the tag number if a stainless tag plate (/SCT) is wanted, because the number is engraved and programmed into the converter at the factory.
Installation and commissioning of SC450G-D-A
Use a supply that stays within 10.8 to 26.4 V DC under load and fuse it according to your site practice. Mounting is by pipe, wall or panel with the optional hardware. Wire the sensor cable to the terminals, which accept finished wires up to 2.5 square mm, then configure the cell and calibrate against an OIML KCl standard. Because the unit has a hold function, mA outputs freeze to the last or a fixed value during calibration so the control loop is not disturbed.
Maintenance and service life
The consumables here are the sensor and its cable, not the converter. Use the logbook to schedule cleaning, and watch for the cell fouling indication. Keep the cover closed while energised, as the housing is marked, and verify gland tightness at each inspection to retain the IP66 rating.
Documents and quotation
A datasheet for SC450G-D-A is attached. For pricing and availability send an RFQ to Seven Star LLC quoting the part number SC450G-D-A, quantity, options and your delivery point.
Other Models in the SC450G Range
Seven Star LLC supplies models from the SC450G range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa SC450G-A-A Conductivity Converter, AC | Liquid Analytical Systems | View details |
| Yokogawa SC450G-D-A Conductivity Converter, 24 V DC | Liquid Analytical Systems | You are viewing this model |
| Yokogawa SC450G-A-U FM Conductivity Converter | Liquid Analytical Systems | View details |
Datasheets & Documents
- Datasheet Yokogawa SC450G-D-A Conductivity Converter, 24 V DC Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa SC450G-D-A Conductivity Converter, 24 V DC
Answers from our engineering team on installation, compatibility and integration.
01Why choose SC450G-D-A instead of the AC version?
SC450G-D-A runs from 12 to 24 V DC, with an acceptable band of 10.8 to 26.4 V DC and 10 W consumption, so it fits skids, solar-powered stations and cabinets that already have a 24 V DC bus.
02Is SC450G-D-A suitable for hazardous areas?
No. The A type letter means general purpose. Only the U type carries FM nonincendive approval for Class I, Division 2, Groups A to D, T6. Choose SC450G-D-U for that need.
03How accurate is the conductivity reading of SC450G-D-A?
The converter specifies conductivity and resistivity within 0.5 percent of reading, temperature within 0.3 C (0.4 C for Pt100) and a 90 percent step response in 4 seconds on a two-decade step.
04What outputs can SC450G-D-A drive?
Two isolated 4-20 mA outputs at up to 600 ohm with HART 5 on mA1, burn-up 21.0 mA or burn-down 3.6 mA fail signalling, and four SPDT relays for alarms, hold, fail-safe on S4 or pulse-controlled dosing.
05What is the ambient temperature range for SC450G-D-A?
Operating ambient is -20 to +55 C and storage is -30 to +70 C, with humidity from 0 to 90 percent RH non-condensing, installation altitude up to 2000 m and IP66 protection.