Brand:

Yokogawa PH450G-D-U FM pH/ORP Converter, 24 V DC

Description

PH450G-D-U in one paragraph

Yokogawa PH450G-D-U combines three choices: the EXAxt 450 pH and ORP converter, a 12 to 24 V DC supply, and the FM nonincendive type. That makes it the converter for classified-area projects whose analyser shelter is fed from a 24 V DC UPS, a combination that appears often on offshore-style skids and packaged water systems. This is the converter-level difference you pay attention to when reading an instrument datasheet.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Specifications for PH450G-D-U

Parameter Value
Power 12 to 24 V DC rating, 10.8 to 26.4 V DC acceptable, 10 W
Area approval FM3611 Class I, Div. 2, Groups A-D, T6, Ta -20 to 55 C
pH / ORP / rH -2 to 16 pH; -1500 to 1500 mV; 0 to 100 rH
Accuracy 0.01 pH; 1 mV; 0.3 C
Display 320 x 240 pixel touchscreen, LED backlight
Housing Cast aluminium, IP66 / NEMA 4X / CSA Type 3S, 144 x 144 x approx. 144 mm, approx. 1.5 kg
Ambient -20 to +55 C; storage -30 to +70 C; 10 to 90 percent RH at 40 C
Standards EN 61010-1, UL 61010-1, EN 61326-1 Class A, EN 50581 RoHS

Why DC and FM go together

In Division 2 areas the cabling and supply are usually restricted; low-voltage DC supply with 10 W demand limits the energy brought to the instrument. SC type EXAxt converters are not intrinsically safe, so the nonincendive listing is about normal operation not producing sparks or heat capable of igniting the gas. PH450G-D-U is specified exactly for that type of requirement, while PH450G-A-A has no hazardous area listing and PH450G-D-U should be compared with it on that point only.

Measurement functions inherited from the PH450G platform

The dual high-impedance input of at least 10 to the 12 ohm measures glass-electrode pH and ORP, with sensor diagnostics based on impedance monitoring. Temperature compensation follows the Nernst equation, with a programmable coefficient, the NEN6411 water and strong acid and base curve, or a programmable matrix. Calibration is semi-automatic one-point or two-point with NIST, US and DIN buffers at pH 4, 7 and 9 or user tables, and each calibration has an automatic stability check.

Contacts can be set for high-low alarms, on-off, PID duty cycle, pulse frequency, hold annunciation, wash start, or fail-safe. The wash function works with a cleaner for the sensor, and a contact input can start a remote wash cycle.

Operating interface and signals on PH450G-D-U

The screen shows the primary variable in large digits, the other variables in small digits, unit symbols, the tag number, a user-programmable process description, the status of the S1 to S4 relays and a status indicator while HOLD or WASH is active. A trend view runs from short intervals up to two weeks and a zoom view lists average, maximum and minimum values. A language menu offers English, German, French, Spanish, Italian, Swedish, Portuguese and Japanese.

Output function can be linear or a 21-step table; burn-up of 21.0 mA or burn-down of 3.6 mA, per NAMUR NE43, tells the control system that the measurement failed. HART 5 on mA1 carries the process variables and diagnostics to PRM, AMS or a handheld, so a technician can read glass impedance and slope data from the control room. The mA outputs carry an additional tolerance of 0.02 mA of 4-20 mA on top of the stated measuring accuracy.

Sensor compatibility is straightforward: use a pH or ORP sensor whose measuring-system code is G, with a temperature element from the supported list (Pt1000, Pt100, 350 ohm, 5k1, 6k8, PTC 10k, NTC 8k55 or 3k Balco). Quote the sensor code in the RFQ so we can confirm the pairing.

How PH450G-D-U differs from PH450G-A-A

The two PH450G units are identical in measurement electronics. The differences are the supply (10 W at 12 to 24 V DC versus 15 VA at 100 to 240 V AC), the approval (FM nonincendive versus none), the cable closure (NEMA 4X plugs versus IP66 glands) and the option list (no /U, /PM, /H5, /AFTG, /ANSI or /AM20 on PH450G-D-U).

Where it is used in Oman and the GCC

The converter fits scrubber control in gas treating units, produced water neutralisation, utilities water treatment inside classified boundaries, and packaged chemical dosing skids supplied with 24 V DC. Water and wastewater plants without classified areas should consider the general purpose version unless the specification demands FM.

Installation, commissioning and care

Check the DC supply polarity and voltage under load before power-up, and fit conduit or glands that comply with your code in the plug locations. Mount with the /UM kit or the plant bracket. After entering the sensor type and the temperature element, calibrate in two buffers. Routine care means cleaning or replacing the pH sensor, using the logbook for dates and the impedance diagnostics for early warning, and keeping the cover closed while the instrument is powered. Because PH450G-D-U is installed in classified surroundings, keep the approval label legible, record the loop number in the logbook, and let the plant permit system decide when the cover may be opened. Replace damaged plugs with the same NEMA 4X type, and re-check the supply voltage at the terminals after any DC bus maintenance. Spare electrodes and buffer solutions should be stocked at the plant so that calibration does not wait for a shipment, and the same applies to the wash-system consumables if a cleaner is installed on the assembly.

Documents and quotation

A datasheet for PH450G-D-U is attached. Send your RFQ to Seven Star LLC with the part number PH450G-D-U, quantity, project area classification and delivery location, and we will respond with availability.

Other Models in the PH450G Range

Seven Star LLC supplies models from the PH450G range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa PH450G-A-A pH/ORP Converter, ACLiquid Analytical SystemsView details
Yokogawa PH450G-D-U FM pH/ORP Converter, 24 V DCLiquid Analytical SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa PH450G-D-U FM pH/ORP Converter, 24 V DC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa PH450G-D-U FM pH/ORP Converter, 24 V DC

Answers from our engineering team on installation, compatibility and integration.

01Is PH450G-D-U powered from AC or DC?
DC. The D code means 12 to 24 V DC, acceptable 10.8 to 26.4 V DC, with a consumption of 10 W. The AC equivalent with the same FM type would be PH450G-A-U.
02What does the U in PH450G-D-U stand for?
U is the FM version with nonincendive approval to FM3611, Class I, Division 2, Groups A to D, T6 for ambient temperatures of -20 to 55 C. It is not an intrinsically safe or explosion-proof rating.
03Can I add a panel kit or awning hood to PH450G-D-U?
The datasheet says option codes /U, /PM, /H5, /AFTG, /ANSI and /AM20 are not specified for the FM version. The /UM universal mounting kit and /SCT tag plate remain on the option list.
04How are the unused conduit entries of PH450G-D-U sealed?
They are fitted with NEMA 4X close-up plugs, which may be replaced by conduit fittings as required by the site, instead of the IP66 cable glands supplied with the general purpose type.
05What outputs does PH450G-D-U have?
Two isolated 4-20 mA outputs with HART 5 on mA1 and four SPDT relays rated 100 VA at 250 V AC and 5 A, which handle alarms, control, wash cycles, hold indication and fail-safe signalling.