Yokogawa FLXA21-D-P-D-CB-C1 IS Conductivity Analyzer
Description
Yokogawa FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 intrinsically safe conductivity analyzer
The Yokogawa FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 is a fully specified FLXA21 two-wire analyzer for contacting conductivity measurement in hazardous areas. It combines a plastic housing, an anti-glare LCD, ATEX and IECEx intrinsically safe approval, a single contacting conductivity input module and a 4 to 20 mA plus HART output. Pipe and wall mounting hardware, a stainless steel tag plate and four M20 conduit adapters complete the order. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Because the analyzer is loop powered, one two-wire cable carries both the supply and the measurement, which keeps wiring in classified areas simple. The Yokogawa FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 identifies a single, fully defined build, so it is the right reference when an existing unit must be matched exactly, for instance when a spare is needed for a plant that already runs the same intrinsically safe conductivity point. The analyzer also accepts a second conductivity module in other configurations, but this code has no second input.
Decoding the FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 code
| Code element | Meaning |
|---|---|
| FLXA21 | 2-wire analyzer |
| -D | Loop-powered supply, always -D |
| -P | Plastic housing |
| -D | Anti-glare LCD |
| -CB | Intrinsically safe for ATEX and IECEx |
| -C1 | First input: conductivity (SC) |
| -NN | No second input |
| -A | 4 to 20 mA plus HART |
| -N | Always -N |
| -LA | English and 11 languages |
| -N | Global except Japan |
| -NN | Always -NN |
| /U | Pipe and wall mounting hardware |
| /SCT | Stainless steel tag plate |
| /CF4 | M20 x 1.5 conduit adapters, 4 pieces |
Every element of FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 is taken from the suffix and option code table in the Yokogawa general specification.
Features of the FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 configuration
- Contacting conductivity input module with two or four electrode measurement and square wave excitation.
- Intrinsically safe type -CB with ATEX marking II 1 G Ex ia IIC T4 Ga (certificate DEKRA 11ATEX0109X) and IECEx Ex ia IIC T4 Ga (IECEx DEK 11.0044X), ambient -20 to 55 C.
- Touch screen operation, sensor wellness indication and logbook.
- HART digital communication superimposed on the 4 to 20 mA loop, with NAMUR 43 burn-out levels.
- Universal pipe and wall mounting, a hanging stainless steel tag plate and conduit adapters delivered with the analyzer.
Together these make the FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 suitable for conductivity monitoring in zone 0 related installations with an appropriate sensor and circuit.
FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 specifications for conductivity service
| Parameter | Value |
|---|---|
| SC input | Two or four electrode measurement with square wave excitation; cell constants 0.005 to 50.0 per cm; up to 60 m cable (WU40/WF10) |
| SC range | 0 microsiemens per cm to 200 mS times the cell constant; resistivity up to 1000 megohm-cm |
| SC accuracy | Plus or minus 0.5 percent F.S. from 2 uS x K to 200 mS x K; plus or minus 1 percent F.S. from 1 to 2 uS x K |
| Temperature inputs | Pt1000 -20 to 250 C; Pt100 -20 to 200 C; Ni100 -20 to 200 C; NTC 8k55 -10 to 120 C; Pb36 -20 to 120 C |
| Temperature accuracy | Plus or minus 0.3 C (Pt1000, Pb36, Ni100); plus or minus 0.4 C (Pt100, NTC 8k55) |
| Step response | 90 percent (under 2 decades) in 7 seconds |
| Power | Nominal 24 V DC loop powered; 16 to 40 V DC for one SC module |
| Display | LCD with touch screen, black and white, 213 x 160 pixels, 12 message languages |
| Housing | Polycarbonate case, silver gray; IP66 (except Canada), NEMA Type 4X, CSA Type 3S/4X |
| Cable entry | M20 cable glands, 3 holes for one sensor or 4 holes for two sensors |
| Size and weight | 144 x 144 x 151 mm without cable gland; approx. 1 kg |
| Ambient temperature | -20 to +55 C; storage -30 to +70 C |
| Humidity | 10 to 90 %RH at 40 C, non-condensing |
| EMC | EN 61326-1 Class A, Table 2 (industrial locations) |
Applications in Oman and GCC hazardous areas
Conductivity indicates salt carry-over, condensate contamination and cooling-water concentration. The FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 suits boiler feedwater and condensate lines in power plants, steam systems in refineries and gas processing facilities, produced water and desalination units, and chemical plants in which an intrinsically safe loop is required. The loop-powered concept avoids extra mains wiring in remote or classified locations.
Selection and compatibility for FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4
The -CB type is for ATEX and IECEx areas; the US and Canada markings use different type codes. Pair the analyzer with a contacting conductivity sensor whose cell constant lies between 0.005 and 50.0 per cm. Yokogawa SC4A pure-water sensors and other SC sensors are described in the sensor datasheets. Check the intrinsically safe entity parameters in the control drawing before connecting a barrier or sensor. The supply for a single module must provide 16 to 40 V DC at the analyzer terminals.
Installation and commissioning of FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4
- Fit the pipe or wall bracket, hang the tag plate, and screw the supplied M20 conduit adapters into the housing holes before connecting cables.
- Wire the loop and the sensor following the control drawing, and avoid electrostatic charging of the plastic enclosure.
- Power up, choose the language, and complete quick setup with date and time, sensor settings and output range.
- Calibrate with a known conductivity standard and confirm the 4 to 20 mA and HART values.
Maintenance and service
Inspect the cover seal and glands at each shutdown, review the logbook for sensor wellness warnings, and recalibrate on schedule. Repairs of intrinsically safe equipment are limited to personnel named by the manufacturer, and modification invalidates the certificate.
Documents and quotation
The Yokogawa general specification GS 12A01A02-01E is available on request and on this page. To receive availability and lead time, send an RFQ with the complete code FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 and the quantity. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Other Models in the Yokogawa Flxa21 Range
Seven Star LLC supplies models from the Yokogawa Flxa21 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa FLXA21 2-Wire Liquid Analyzer Transmitter | Liquid Analytical Systems | View details |
| Yokogawa FLXA21-D-P-D-CB-C1 IS Conductivity Analyzer | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Yokogawa FLXA21-D-P-D-CB-C1 IS Conductivity Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa FLXA21-D-P-D-CB-C1 IS Conductivity Analyzer
Answers from our engineering team on installation, compatibility and integration.
01What is FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4?
It is a Yokogawa FLXA21 two-wire conductivity analyzer in plastic housing with ATEX and IECEx intrinsic safety, one SC input, 4 to 20 mA plus HART, pipe and wall hardware, a stainless tag and M20 adapters.
02What does the -CB code mean?
In the specification, -CB is the intrinsically safe type for ATEX and IECEx, with marking II 1 G Ex ia IIC T4 Ga and ambient range of -20 to 55 C.
03Which sensors connect to this FLXA21 configuration?
The SC module accepts two or four electrode contacting conductivity sensors with cell constants from 0.005 to 50.0 per cm and temperature elements such as Pt1000 or Pt100.
04What outputs and power does it use?
One 4 to 20 mA output with HART, loop powered, with 16 to 40 V DC required for a single sensor module.
05How do I order FLXA21-D-P-D-CB-C1-NN-A-N-LA-N-NN/U/SCT/CF4 in Oman?
Send an RFQ quoting the complete code and the quantity. Seven Star LLC is an independent supplier and replies with availability for Oman and the GCC.