Brand:

Yokogawa SC450G-A-A Conductivity Converter, AC

Description

Yokogawa SC450G-A-A overview

Yokogawa SC450G-A-A is the mains-powered, general purpose build of the EXAxt 450 conductivity and resistivity converter. It is a four-wire instrument in a 144 by 144 mm housing that reads a two-electrode or four-electrode cell, compensates the reading for temperature, and presents the result on a quarter-VGA touchscreen. In our own customer enquiries, this part number is typically requested as a straight like-for-like replacement for an ageing converter on a boiler, demineralised-water or cooling-tower loop.

The model name carries the meaning. SC450G is the converter, the first suffix A selects an AC supply, and the second suffix A selects the general purpose type, as opposed to the FM nonincendive variant. Everything else on this page follows from that two-letter choice, so a request for SC450G-A-A is specific enough to be quoted without a drawing.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Features that matter on a conductivity loop

  • High-resolution graphical display, 320 by 240 pixels, LED backlit, with touch operation and plain-language messages in English, German, French, Spanish, Italian, Swedish, Portuguese and Japanese.
  • Trend screen with a time base between 15 minutes and 2 weeks, plus on-screen logbooks for calibration, configuration changes and events.
  • Cell fouling monitoring, so a coating on the electrodes is flagged before it distorts the reading.
  • Compensation to the IEC 60746-3 NaCl tables by default, with two user programmable temperature coefficients from 0 to 3.5 percent per degree.
  • Ultra pure water, steam, condensate and boiler water functions, including cation, ammonia and morpholine conductivity, and the USP chapter 645 behaviour for pharmaceutical water.
  • Matrix compensation: 13 preprogrammed concentration matrices and two user-entered 100-point matrices for strong acids and alkalis.

SC450G-A-A technical specifications

Parameter Value
Model and suffix SC450G-A-A (AC power, general purpose type)
Power supply 100 to 240 V AC, acceptable 90 to 264 V AC, 50/60 Hz, 15 VA
Conductivity input range 0.000 uS/cm to 2000 mS/cm, maximum 200 mS times cell constant
Resistivity input range 0.0 ohm-cm to 1000 Mohm-cm
Cell constant 0.005 to 50.0 per cm, two or four electrodes, square wave excitation
Temperature inputs Pt1000 -20 to 250 C; Pt100 and Ni100 -20 to 200 C; NTC 8k55 -10 to 120 C; Pb36 -20 to 120 C
Accuracy Conductivity and resistivity within 0.5 percent of reading; temperature within 0.3 C (0.4 C for Pt100)
Step response Within 4 s for 90 percent on a two decade step
Current outputs Two isolated 4-20 mA, common negative, 600 ohm maximum load, tolerance 0.02 mA
Digital HART 5 superimposed on mA1
Relays Four SPDT, 100 VA at 250 V AC 5 A, or 50 W at 250 V DC 5 A
Enclosure Cast aluminium, polycarbonate window, IP66 / NEMA 4X / CSA Type 3S, silver grey
Size and weight 144 x 144 x approx. 144 mm, approx. 1.5 kg
Ambient / storage -20 to +55 C operating, -30 to +70 C storage, 0 to 90 percent RH non-condensing

How SC450G-A-A differs from other SC450G variants

The SC450G suffix matrix has only two decisions, and both change what arrives. Versus SC450G-D-A the supply is different: this part takes 100 to 240 V AC at 15 VA, while the D version runs on 12 to 24 V DC at 10 W. Versus SC450G-A-U the type letter is different: this part ships with IP66 cable glands, while the U version carries FM nonincendive approval for Class I, Division 2, Groups A to D, T6 at ambient temperatures from -20 to 55 C, and arrives with NEMA 4X plugs in the unused entries.

There is one practical rule for the options: the pipe and wall hardware /U, panel hardware /PM, awning hood /H5 and the three conduit adapters /AFTG, /ANSI, /AM20 are not offered with the FM U type. They are available on SC450G-A-A, which is a reason many general plant buyers choose it.

Typical applications in Oman and the GCC

Desalination and water treatment plants use SC450G-A-A behind reverse osmosis stages to watch permeate conductivity, trip a relay when salt passage rises, and send the value to the control system through the 4-20 mA signal. Power stations and cogeneration units apply the steam and condensate compensation modes to cation conductivity after the sample cooler. In refineries and petrochemical sites in Sohar, Duqm and Sur, the converter supervises cooling-water cycles and condensate return, and in food and beverage plants it checks CIP rinse and caustic strength through the matrix functions.

Selection and compatibility notes

Check the sensor first. The converter is universal, but the cell constant, the temperature element and the cable (WU40 or WF10, up to 60 m) must match the sensor you hold. Contact Seven Star with the sensor model and the data tag so the compatibility can be confirmed before the offer is issued.

Confirm that the 100 to 240 V AC feed is available at the field mounting point. If the cabinet only offers 24 V DC, the D variant is the correct choice instead. For outdoor pipe mounting in direct sun, mention /H5 awning hood in the enquiry.

Installation and commissioning of SC450G-A-A

Mount the 144 mm housing on a pipe, wall or panel using the kit that matches your order. Pass the supplied IP66 glands through the six cable entries, keep sensor cable away from power wiring, and tighten each gland properly because weather protection depends on it. After power-up, pick the language, select the cell type and constant, enter the temperature element, then run the semi-automatic calibration with the preloaded OIML KCl tables. The converter checks stability automatically before it accepts the point.

Maintenance

Routine work is limited to sensor cleaning and periodic calibration. The logbook helps by showing when the last calibration happened and whether fouling alerts have appeared. The configuration and logbook are held in EEPROM, and a lithium cell keeps the clock, so a mains interruption does not erase settings. If the relay load exceeds 4 A, keep the ambient temperature under 40 C as the datasheet requires.

Related products and ordering notes

Customers often pair SC450G-A-A with a Yokogawa conductivity cell and cable, or ask about the sister EXAxt 450 pH and ORP converter. Quote the supply voltage, the option codes and the tag text for /SCT so the order can be matched exactly.

Documents and quotation

The datasheet for SC450G-A-A is attached to this page. To receive a quotation, send an RFQ to Seven Star LLC with the part number SC450G-A-A, the quantity, the option codes and your delivery location in Oman or the GCC.

Other Models in the SC450G Range

Seven Star LLC supplies models from the SC450G range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa SC450G-A-A Conductivity Converter, ACLiquid Analytical SystemsYou are viewing this model
Yokogawa SC450G-D-A Conductivity Converter, 24 V DCLiquid Analytical SystemsView details
Yokogawa SC450G-A-U FM Conductivity ConverterLiquid Analytical SystemsView details
Datasheets & Documents
  • PDF Datasheet Yokogawa SC450G-A-A Conductivity Converter, AC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa SC450G-A-A Conductivity Converter, AC

Answers from our engineering team on installation, compatibility and integration.

01What power supply does the Yokogawa SC450G-A-A need?
The first suffix letter A means the AC version: rated 100 to 240 V AC at 50/60 Hz, acceptable 90 to 264 V AC, drawing about 15 VA. It is the mains-powered converter and is not the 12 to 24 V DC variant.
02What does the second A in SC450G-A-A mean?
It selects the general purpose type with IP66 cable glands supplied in the box. The U type is the FM nonincendive version, which ships with NEMA 4X close-up plugs instead of glands.
03Which temperature elements and cell constants can SC450G-A-A read?
It accepts Pt1000, Pt100, Ni100, NTC 8k55 and Pb36 elements, plus two- or four-electrode cells with cell constants from 0.005 to 50.0 per cm over cable runs of up to 60 m with WU40 or WF10 cable.
04Does SC450G-A-A provide HART and relay outputs?
Yes. It has two isolated 4-20 mA outputs with HART 5 superimposed on the first one, and four SPDT relays rated 100 VA at 250 V AC and 5 A, usable for alarms, PID duty cycle or pulse control of dosing pumps.
05Can I order mounting hardware with SC450G-A-A?
Option codes include /UM universal kit, /U pipe and wall hardware, /PM panel hardware, /H5 stainless awning hood, /AFTG, /ANSI and /AM20 conduit adapters and /SCT tag plate. Please quote the options you need with the RFQ.