- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa FLXA402 Multi-Channel 4-Wire Liquid Analyzer
Description
Overview of the Yokogawa FLXA402
The Yokogawa FLXA402 is a multi-channel 4-wire liquid analyzer converter that combines the functionality of the Yokogawa EXAxt series with modern digital sensor technology. It accepts traditional analog sensors as well as SENCOM 4.0 digital smart sensors, and with the appropriate modules it measures pH and ORP, resistivity and conductivity, inductive conductivity and dissolved oxygen. Up to five sensor measurements can be handled by one converter, and a colour touchscreen with menus in 11 languages keeps start-up and commissioning time short.
Seven Star LLC supplies the Yokogawa FLXA402 together with Yokogawa sensors, holders and cables to water utilities, desalination plants, power stations and process industries across the Sultanate of Oman and the GCC. As a trusted supplier with engineering support in Muscat, we help configure the sensor modules, outputs and mounting hardware for each analyzer point before quotation.
Operating Principle
The Yokogawa FLXA402 is a modular converter: the measurement function is defined by the sensor modules inserted into its two slots. Analog modules are available for pH/ORP with dual high-impedance inputs, for contacting conductivity and resistivity sensors, for inductive (toroidal) conductivity sensors, and for galvanic or polarographic membrane dissolved oxygen sensors. Digital modules connect the SA11 SENCOM Smart Adapter, which digitises pH, ORP and conductivity sensor signals at the sensor, or the DO71/DO72 optical dissolved oxygen sensors.
Each module processes its sensor signal with temperature compensation from Pt1000, Pt100, NTC and other elements, and the converter scales the results to its 4–20 mA outputs, relays and digital interfaces. When more than one sensor is connected, the Yokogawa FLXA402 can calculate derived values such as the ratio or percentage deviation between two sensors, which is useful for redundant pH measurement or for reverse osmosis rejection calculations. Sensor wellness indication and a software event log support predictive maintenance.
Engineering Design of the Yokogawa FLXA402
The converter is housed in a cast aluminium alloy case with a chemically resistant or high anti-corrosion coating and a flexible polycarbonate window, rated IP66 and NEMA Type 4X. The housing measures 165 × 165 × 168.5 mm, weighs at most 3.0 kg and has eight M20 cable entries, with G½, ½ NPT and M20 conduit adapters available. Optional universal, pipe, wall and panel mounting kits and a stainless steel hood make it suitable for outdoor field installation as well as analyzer panels.
The QVGA colour touchscreen displays values, trends and diagnostics, and the FLXA402-A version runs on 100–240 V AC while the FLXA402-D version uses 12–24 V DC. Output modules offer two isolated 4–20 mA outputs with one contact input, or four outputs with two contact inputs and one 4–20 mA input. Four SPDT relays handle alarms, wash cycles, hold indication and a fail-safe contact. Maintenance data can be exchanged by SD card, Ethernet, RS-485 or Bluetooth with Yokogawa FieldMate.
Key Features
The Yokogawa FLXA402 brings together the following features from its general specifications:
- Multi-parameter measurement of pH/ORP, conductivity/resistivity, inductive conductivity and dissolved oxygen in one converter.
- Connection of analog sensors, SENCOM 4.0 smart sensors via the SA11 adapter, and DO71/DO72 optical DO sensors.
- Up to five sensor measurements using a SENCOM SA module with the BA11 active junction box.
- pH accuracy of ±0.01 pH and conductivity accuracy of ±0.5 % of full scale with simulated inputs.
- Two or four isolated 4–20 mA outputs, accuracy ±0.02 mA, with HART 7 on the first output and NAMUR NE43 burn-out.
- Four SPDT relay contacts rated up to 250 V AC / 5 A, with high/low alarms, wash control and fail-safe function.
- Optional Modbus TCP over Ethernet or Modbus RTU over RS-485, plus Bluetooth for local access.
- IP66/NEMA 4X coated aluminium housing for field mounting at −20 to +55 °C ambient temperature.
Industrial Applications
The multi-sensor design suits water and wastewater treatment, where several parameters are measured at one point. In Oman, the Yokogawa FLXA402 is well suited to seawater reverse osmosis desalination plants at Barka, Sohar, Sur and Salalah, monitoring pH, ORP and conductivity of feed and permeate and dissolved oxygen in post-treatment. Power and water plants use it for boiler feedwater, condensate and cooling water chemistry, while municipal sewage treatment plants use dissolved oxygen and pH measurement to control aeration and dosing.
Refineries, petrochemical and fertiliser plants in Sohar and Duqm apply the Yokogawa FLXA402 to effluent neutralisation, produced-water treatment and chemical concentration measurement with inductive conductivity sensors. Seven Star LLC supplies the converter from Muscat with the right sensors and fittings, and can combine it with the Yokogawa FLXA21 dissolved oxygen analyzer for two-wire points, the Yokogawa ADMAG AXG magnetic flowmeter or the KROHNE OPTIFLUX 2000 electromagnetic flowmeter for flow measurement on the same water lines.
Technical Specifications of the Yokogawa FLXA402
The table summarises data for the Yokogawa FLXA402 from Yokogawa General Specifications GS 12A01F01-01EN (10th edition).
| Parameter | Specification |
|---|---|
| Model | Yokogawa FLXA402 4-Wire Converter |
| Measurement objects | pH/ORP, conductivity/resistivity, inductive conductivity, dissolved oxygen |
| Sensor inputs | 2 module slots; up to 5 measurements with SENCOM SA and BA11 |
| pH input range | −2 to 16 pH; ORP −1500 to 1500 mV |
| pH accuracy | ±0.01 pH (simulated input) |
| Conductivity range | Up to 2000 mS/cm output span; accuracy ±0.5 % F.S. |
| Dissolved oxygen | 0 to 50 mg/l (membrane sensors); optical DO71/DO72 sensors |
| Analog outputs | 2 or 4 isolated 4–20 mA, HART 7 on mA1, max. load 600 Ω |
| Contact outputs | 4 SPDT relays, max. 250 V AC 5 A / 50 V DC 5 A |
| Digital communication | Modbus TCP (Ethernet) or Modbus RTU (RS-485); Bluetooth option |
| Display | QVGA colour touchscreen LCD, 11 languages |
| Power supply | 100–240 V AC (35 VA) or 12–24 V DC (15 W) |
| Housing / protection | Coated aluminium alloy; IP66, NEMA Type 4X |
| Dimensions / weight | 165 × 165 × 168.5 mm; max. 3.0 kg |
| Ambient temperature | −20 to +55 °C |
| Hazardous area | FM nonincendive Class I, Division 2 version available |
How to Order
Send Seven Star LLC an RFQ for the Yokogawa FLXA402 with the parameters to be measured, sensor types and quantities, process temperature and pressure, required outputs and communication protocol, power supply and mounting method. Our instrumentation division in Muscat will confirm the model and suffix codes, recommend matching sensors and holders, and confirm current availability and lead time. The general specifications can be downloaded from this page, and our engineers support customers in Oman and the GCC through installation and calibration.
Datasheets & Documents
- Datasheet Yokogawa FLXA402 4-Wire Converter General Specifications (GS 12A01F01-01EN, 10th Ed.) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa FLXA402 Multi-Channel 4-Wire Liquid
Answers from our engineering team on installation, compatibility and integration.
01Which parameters can the Yokogawa FLXA402 measure?
With the corresponding sensor modules, the FLXA402 measures pH and ORP, resistivity and conductivity, inductive conductivity including % concentration, and dissolved oxygen with membrane or optical sensors. A 4–20 mA input can bring in a further signal, for example for temperature or pressure compensation.
02How many sensors can be connected to one FLXA402?
The converter has two sensor module slots. Two analog or digital sensors can be connected directly, and with a SENCOM SA module and the BA11 active junction box up to five sensor measurements are possible on one converter, with calculated values such as ratio and deviation between sensors.
03What outputs and communication options are available?
The FLXA402 provides two or four isolated 4–20 mA outputs with HART 7 on the first output, four SPDT relay contacts, contact inputs, and optional Modbus TCP over Ethernet or Modbus RTU over RS-485. Bluetooth is available for local access with FieldMate on a tablet PC.
04Where can the FLXA402 be installed?
The converter has an aluminium alloy housing with corrosion-resistant coating rated IP66 and NEMA Type 4X, for field, pipe, wall or panel mounting. It operates from −20 to +55 °C and is offered for 100–240 V AC or 12–24 V DC supply, with an FM nonincendive version for Class I, Division 2 areas.
05Does Seven Star LLC supply the Yokogawa FLXA402 in Oman?
Yes. Seven Star LLC supplies Yokogawa liquid analyzers, sensors and holders to water, desalination, power and process customers in Muscat, Sohar, Duqm and Salalah and across the GCC, with engineering support in Muscat.


















Reviews
There are no reviews yet.