SICK LFP0700-A5DMC LFP Cubic Capacitive Level Sensor
Description
LFP0700-A5DMC, part no. 1071096, is a SICK LFP Cubic level probe for fluids that reports the filling level as a switching signal or as a continuous analog value. The catalogue summary lists: communication interface: IO-Link; process connection: G ¾ A; probe length: 700 mm; probe type: Rod probe; remote amplifier: Yes, length of cable 3.3 m.
What the LFP0700-A5DMC does in a machine
Conductive and non-conductive liquids can both be measured, and foam and deposits can be partly compensated. The probe has no moving parts, so there is no wear and no mechanical float to stick in viscous media.
The data sheet gives the dead zones at the process connection and at the probe end where no reading is possible, which must be considered when positioning the probe in the vessel. Switching points and the analog span are set on the amplifier or over IO-Link, so a single device can replace a float switch and a transmitter.
Technical specifications
| Parameter | Specification |
|---|---|
| Type code | LFP0700-A5DMC |
| Part number | 1071096 |
| Product family | LFP Cubic |
| Medium | Fluids |
| Measurement | Switch, Continuous |
| Design | Remote amplifier |
| Probe type | Rod probe |
| Probe length | 700 mm |
| Process pressure | –1 bar … 10 bar |
| Process temperature | –20 °C … +100 °C |
| Accuracy of sensor element | ± 5 mm |
| Reproducibility | ≤ 2 mm |
| Resolution | 1 mm |
| Response time | 400 ms |
| Dielectricity constant | ≥ 5 for rod probe / cable probe; ≥ 1.8 with coaxial tube |
| Conductivity | No limitation |
| Maximum level change | ≤ 500 mm/s |
| Deactivated area at process connection | 25 mm |
| Deactivated area at end of probe | ≥ 10 mm |
| MTTF | 194.3 years (EN ISO 13849-1) |
| Communication interface | IO-Link |
| Supply voltage | 12 V DC … 30 V DC |
| Power consumption | ≤ 75 mA at 24 V DC without output load |
| Connection type | M12 round connector x 1, 8-pin |
| Length of cable | 3.3 m |
| Output signal | 1 x PNP + 3 x PNP/NPN + 4 mA … 20 mA / 0 V … 10 V |
| Output load | 4 mA … 20 mA 13,5 V, 4 mA … 20 mA 12 V, 0 V … 10 V > 750 Ohm at Uv ≥ 14 V |
| Output current | < 100 mA |
| Inductive load | < 1 H |
| Capacitive load | ≤ 100 nF |
| Declarations and certificates in the data sheet | EU declaration of conformity; UK declaration of conformity; ACMA declaration of conformity; Moroccan declaration of conformity; China RoHS; China Compulsory Product Certification (CCC) exempt; cULus certificate; IO-Link certificate; Information according to Art. 3 of Data Act (Regulation EU 2023/2854) |
Selection and installation notes for LFP0700-A5DMC
On the electrical side, the data sheet gives power draw of ≤ 75 mA at 24 V DC without output load; supply of 12 V DC … 30 V DC; interface of IO-Link; connection of M12 round connector x 1, 8-pin; current of < 100 mA; response time of 400 ms; resolution of 1 mm.
Before choosing the mounting position, check operating temperature –20 °C … +60 °C; enclosure rating IP67 (EN 60529); housing plastic PBT.
Probe length cannot be cut to size unless the manufacturer states it.
For installation, keep the probe clear of the tank wall and inlets, respect the dead zones and the maximum probe load, and avoid direct filling streams hitting the rod.
Related SICK products: SICK IME18-05BPSZC0S Inductive Sensor, SICK IME12-04BPPZC0S Inductive Sensor, SICK IME12-04BPSZC0K Inductive Sensor, SICK DT500-A111 Dx500 Distance Sensor, SICK RFU620-10104 RFU62x Identification Sensor and SICK WLA16P-24162100A00 Retro-Reflective Sensor.
Documents and quotation
Use the attached SICK data sheet (LFP0700-A5DMC, part no. 1071096) to check wiring, mounting and approvals. Quotations are prepared by Seven Star LLC, an independent supplier in Muscat, once you send the part number, quantity and site through the RFQ form. Browse more in Level Instrumentation. Compare the complete type code with your existing unit and controller before ordering; the data sheet prevails if it differs from this page.
Datasheets & Documents
- Datasheet SICK LFP0700-A5DMC official data sheet (part no. 1071096) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.
SICK company profile
| Founded | 1946, Munich, Germany, by Erwin Sick (1909–1988) |
|---|---|
| Headquarters | Waldkirch, Baden-Württemberg, Germany (since 1956) |
| Ownership | Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996 |
| Size | More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023) |
| First breakthrough | Accident-prevention light curtain for presses, shown in Hanover in 1952 |
| International growth | First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide |
| Product families | Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring |
Milestones
- 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
- 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
- 1956: The company moves to Waldkirch with 25 employees.
- 1972 and 1976: Subsidiaries are founded in France and the United States.
- 1996: SICK becomes an Aktiengesellschaft.
- Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.
Choosing a SICK sensor
For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.
Where SICK products are used
In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.
SICK products we list
| Family | Examples |
|---|---|
| Photoelectric sensors | WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link |
| Proximity, cylinder and ultrasonic sensors | IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork |
| Machine safety | nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD |
| Encoders and motor feedback | DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50 |
| Distance sensors and code readers | DT50, DL50, DT35, Lector632 |
Ordering SICK products: what we need
Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.
Frequently requested SICK models: SICK RT-P3231 ZoneControl Background Suppression Sensor.
Facts checked against SICK's published company history and annual figures, October 2026.
Browse SICK products by category: Sensors & Transmitters.
FAQ
Questions about the SICK LFP0700-A5DMC LFP Cubic Capacitive Level Sensor
Answers from our engineering team on installation, compatibility and integration.
01What is the SICK LFP0700-A5DMC?
It is a SICK capacitive level sensor (LFP Cubic), part no. 1071096. The catalogue summary reads: Communication interface: IO-Link; Process connection: G ¾ A; Probe length: 700 mm; Probe type: Rod probe.
02Which supply voltage applies to the LFP0700-A5DMC?
Supply voltage is 12 V DC ... 30 V DC. Check the output and interface rows in the table for the signal levels.
03What protection rating and temperature range are given?
Enclosure rating: IP67 (EN 60529). Ambient operating temperature: –20 °C ... +60 °C. Confirm both against the site before ordering.
04Does the page include the data sheet?
Yes. The official SICK data sheet for part no. 1071096 is attached as a PDF and linked on this page; where it differs from the page text, the data sheet applies.
05What should be confirmed before ordering the LFP0700-A5DMC?
Compare the full type code and part number 1071096 with the device being replaced, check supply, output or interface and mounting, and send the details through the RFQ form. Seven Star LLC is an independent supplier, not a SICK partner.