Brand:

Turck LS-534-0300-LIU24PN8X-H1181 Guided Wave Level Sensor 300

Description

LS-534-0300-LIU24PN8X-H1181 in brief

LS-534-0300-LIU24PN8X-H1181 is a level sensor with a 300 mm cut-to-length probe, an analog output (4 to 20 mA or 0 to 10 V), four switching or IO-Link outputs in total, a 3/4-inch NPT male process thread and a rotatable display housing.

Datasheet feature summary: Multiple output signals: one system for; 1x transistor output (PNP) or IO-Link; High flexibility due to cutable probe; Process pressure up to 145 psi; Coaxial tubes available for non-metallic; Process connection NPT 3/4″ male thread; Small inactive areas, ideal for small; 1x analog output 4… 20 mA/0… 10 V; Low maintenance and quick commissioning.

Technical specifications

Parameter Specification
Type LS-534-0300-LIU24PN8X-H1181
Ident number 100001855
ID no. 100001855
Medium temperature -20…+100 °C
Application area liquids
Probe length (L) 300 mm
Max. loading of probe 6 Nm
Probe accuracy ± 5 mm
Temperature drift ≤ 0.1
Hysteresis ≥ 2 mm
Repeatability ≤ 2 mm
Inactive area at process connection 25 mm
Inactive area at probe end 10 mm
Dielectric constant ≥5
Pressure resistance -1…10 bar
Operating voltage 12…30 VDC
Current consumption ≤ 100 mA
Short-circuit/reverse polarity protection yes / yes
Inductive load <1 H
Capacitive load 100 nF
Insulation class III
Output 1 Analog output (current/voltage, automatic
Output 2 IO-Link/switching output (PNP)
Output 3 Switching output (PNP/NPN)
Output 4 Switching output (PNP/NPN)
Output 5 Switching output (PNP/NPN)
Communication protocol IO-Link
Output function NO/NC, PNP/NPN, analog output
Current output 4…20 mA
High level signal current 20…20.5 mA
Low level signal current 3.8…4 mA
Load resistance current output ≤ 0.5 kΩ
Voltage output 0…10 V
High level signal voltage Uv – 2 V
Low level signal voltage ≤2V
Load resistance voltage output ≥ 0.75 kΩ

Application notes

One device provides continuous level and point-level switching, so a single probe can cover a low alarm, a pump on/off pair and a continuous signal for the PLC. The probe is stainless steel 1.4404 with PTFE, can be shortened on site, and the datasheet gives a 5 mm probe accuracy, a 25 mm inactive area at the process connection and a minimum dielectric constant of 5. Process temperature is -20 to +100 C and pressure up to 10 bar.

At commissioning, teach the empty and full points, set the switching outputs to the alarm levels you need, and confirm the analog scaling in the PLC. Foam, coating or a medium with a low dielectric constant can shift the reading, so check against a known level.

Reading the type code before you order

Derived from the datasheet: the series name LS-5xx is followed by a probe-length figure where printed (300 mm here), the output block (analog plus switching outputs as in the datasheet title) and the connector code. The process thread is n/a. Ident number 100001855 identifies this exact version.

Points to confirm with us before ordering: the output configuration, the process thread type (G or NPT), the medium and its dielectric constant, the tank depth against the probe length, and process temperature and pressure. Everything in the table comes from the datasheet as published, so the maker document is the final reference.

Documents and quotation

Datasheet: PDF. It is the manufacturer’s own document for LS-534-0300-LIU24PN8X-H1181, kept unaltered. To request pricing and delivery, give us the full code LS-534-0300-LIU24PN8X-H1181, the quantity and your project reference. Seven Star LLC supplies as an independent supplier in Muscat. Related items sit in Level Instrumentation.

Datasheets & Documents
  • PDF Datasheet Turck LS-534-0300-LIU24PN8X-H1181 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Turck is the German automation company for sensors, connectivity, fieldbus I/O and interface technology. It grew from Hans Turck's engineering office in Mülheim an der Ruhr: in 1965 a chemical plant ordered an isolation amplifier for intrinsically safe circuits, and the first 20 units were built by his brother Werner Turck in Halver. The family-owned Turck group is still headquartered in Mülheim an der Ruhr, with production in Halver and other sites.

Seven Star LLC is an independent supplier in Muscat. We list Turck sensors and I/O devices for machine builders and maintenance teams in Oman and the GCC.

Turck company profile

Founded 1965, Germany, by the brothers Hans and Werner Turck
First product An isolation amplifier with intrinsically safe circuits for explosion-protected areas, first supplied to Chemische Werke Hüls
Headquarters Mülheim an der Ruhr, Germany; production in Halver
Ownership Family-owned group; Turck Holding was formed in 1994
Product families Inductive, capacitive and ultrasonic sensors, TBEN block I/O and fieldbus modules, IO-Link masters and hubs, connectors and cordsets, isolating barriers and interface modules, RFID systems

Milestones

  • 1965: An order from a German chemical plant for an amplifier module starts the business; Werner Turck builds the first 20 units.
  • 1970: Hans Turck KG and Werner Turck KG are registered as separate companies.
  • 1975: Hans Turck KG opens its building in Mülheim an der Ruhr.
  • 1994: Turck Holding combines the two Turck companies under one roof.

Turck product series

Most of the Turck products here are inductive proximity sensors: threaded M12, M18 and M30 barrels in flush (BI) and non-flush (NI) versions, uprated-range (U) sensors, rectangular CP40 and CP80 housings and BIM magnetic-field sensors for detecting pistons in pneumatic cylinders. The type code describes the sensor; in BI5-M18-AP6X-H1141, BI means flush mounting, 5 is the switching distance in mm, AP6X a three-wire PNP output and H1141 the M12 connector.

Turck also makes RU ultrasonic sensors, PS pressure, TS temperature and LS level sensors, FCI inline flow sensors, the CMVT vibration and temperature sensor for condition monitoring over IO-Link, and fieldbus and Ethernet I/O modules and communication components.

Where Turck sensors are used

Position detection on conveyors, packaging machines, presses and robotic cells; level, pressure and temperature monitoring on hydraulic units and process skids; and vibration monitoring on motors, pumps and fans.

Turck products we list

Family Examples
Inductive Proximity Sensors BI10U-M30-AP6X-H1141 M30 Flush Inductive, BI15-CP40-VP4X2-H1141 CP40 Rectangular, BI2-M12-VP6X M12 Flush Inductive Sensor 2 mm, BI5-M18-AP6X-H1141 Inductive Proximity Sensor, BI5U-M18-AP6X-H1141 M18 Flush Inductive, BI8U-M18-AP6X-H1141 M18 Flush Inductive, BIM-M12E-AP4X-H1141 M12 Magnetic-Inductive, NI12U-S18-VP6X-H1141 M18 Plastic Inductive and 3 more
Ultrasonic Sensors RU100L-M18M-UP8X2-H1151 M18 Ultrasonic, RU100U-M18MS-UP8X2-H1151 M18 Ultrasonic Sensor, RU130U-M18E-LIU2PN8X2T-H1151 M18 Ultrasonic, RU130U-M30E-2UP8X2T-H1151 M30 Ultrasonic, RU300U-M30E-LIU2PN8X2T-H1151 M30 Ultrasonic
PLC & I/O Cards TBEN-L4-8DIP-8DOP Block I/O Module 8 PNP, TBEN-L5-16DOP Block I/O Module 16 PNP Outputs, TBEN-S1-8DIP Block I/O Module 8 PNP Inputs M8, TBEN-S2-8DIP Block I/O Module 8 PNP Inputs M8
Magnetic, Cylinder & Capacitive Sensors BIM-UNT-AP6X/S97/S1165 T-Slot Cylinder
Vibration Monitoring CMVT-QR20 Vibration & Temperature Sensor
Flow Indicators & Switches FCI-D04A4P-AP8X-H1141 Inline Flow Sensor
Level Instrumentation LS-551-0700-LIU24PN8X-H1181 Level Sensor
Pressure Instrumentation PS510-16V-01-LI2UPN8-H1141 Pressure Sensor
Temperature Instrumentation TS700-L016-16-LI2UPN8-H1141 Temperature Sensor

Ordering Turck sensors: what we need

Send the full type code and the six- or seven-digit ID number printed on the sensor or its label. If the label is missing, give the housing size, flush or non-flush mounting, switching distance, output type (PNP or NPN, NO or NC), supply voltage and connection (cable or connector).

Facts checked against Turck's published company history, October 2026.

Frequently Asked Questions

What medium and temperature does LS-534-0300-LIU24PN8X-H1181 suit?
Application area liquids; medium temperature -20…+100 °C; pressure resistance -1…10 bar.
What outputs does LS-534-0300-LIU24PN8X-H1181 provide?
NO/NC, PNP/NPN, analog output; current output 4…20 mA, voltage output 0…10 V; IO-Link V 1.1.
What process connection does LS-534-0300-LIU24PN8X-H1181 use?
3/4" NPT male thread; wetted parts Stainless steel 1.4404 (AISI 316L), PTFE,.
What accuracy does LS-534-0300-LIU24PN8X-H1181 state?
Probe accuracy ± 5 mm, repeatability ≤ 2 mm, hysteresis ≥ 2 mm.
What should I confirm before ordering LS-534-0300-LIU24PN8X-H1181?
Confirm the output configuration, the process thread type (G or NPT), the medium and its dielectric constant, the tank depth against the probe length, and process temperature and pressure.