Brand
Magnetrol
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021. Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Read the full brand profile ↓- 7 products
- 4 categories
7 products
Brand profile
About Magnetrol
- Founded
- 1932
- Headquarters
- Aurora, USA
- Speciality
- Level and flow instrumentation
- Listed with us
- 7 products in 4 categories
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don’t affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Magnetrol products by category
Request a Quote for Magnetrol Products
Looking for Magnetrol parts not listed here, or pricing for a project? Send us the part numbers and quantities. Seven Star LLC sources genuine Magnetrol products for customers across Oman and the GCC and replies with a formal quotation.
- Genuine OEM products
- Supply across Oman & the GCC
- Formal quotation from our sales team
Free, no-obligation quotation · takes about 1 minute
Other enquiries: [email protected] · WhatsApp
FAQ
Questions about Magnetrol
Common questions about Magnetrol equipment, part numbers and supply to Oman and the GCC.
01Does the Eclipse 706 replace the earlier Eclipse 705?
The Model 706 is the later generation of the Eclipse guided wave radar transmitter and is the model listed here. When replacing a 705, the existing probe and the transmitter head have to be checked together, so send both model numbers and the serial number. We compare them with the manufacturer's documentation before confirming what can be reused.
02How do I choose between Pulsar R96, R86 and R80?
They are non-contact radar transmitters working at 6 GHz, 26 GHz and 80 GHz. Higher frequency gives a narrower beam and allows a smaller antenna, which helps with small nozzles and internal obstructions, while lower frequency copes better with some difficult surface conditions. Send the tank drawing, nozzle size, fluid and process conditions for a selection check.
03Why are two model numbers needed for an Eclipse guided wave radar?
The Eclipse is ordered as two items: the transmitter head with its electronics and housing, and the probe that enters the vessel. Each has its own model number on its own nameplate, and the probe code includes type, material, process connection and length. Without the probe number the wetted part of the instrument is undefined.
04What is the difference between Echotel 961 and 962?
Both are ultrasonic level switches that detect liquid in a gap at the tip of the transducer. The 961 has a single switching point, and the 962 has two points on one transducer for duties such as pump on and off control. Send the insertion length, process connection and output type when ordering.
05Is Seven Star LLC a distributor of Magnetrol?
No. Seven Star LLC is an independent supplier and is not a distributor, agent or service center of Magnetrol. We source Magnetrol instruments through commercial channels, check the model number against the manufacturer's documentation, and provide the manufacturer's datasheet and the certificates the manufacturer issues with the order on request.