Brand: Rosemount
Rosemount 8732EM Field Mount Magnetic Flow Transmitter
Description
Rosemount 8732EM field-mount magnetic flow transmitter and its model code
The Rosemount 8732EM is the field-mount transmitter of the Rosemount 8700M magnetic flow meter platform. It drives the coils of an electromagnetic sensor, reads the electrode signal and turns it into a flow value that can leave the instrument as 4–20 mA with HART, a scalable pulse, FOUNDATION Fieldbus, Modbus RS-485 or EtherNet/IP. It can be bolted straight onto a sensor (integral mount) or placed on a pipe stand or wall with a cable kit (remote mount). Seven Star LLC supplies 8732EM transmitters and matching sensors in Oman and the GCC as an independent supplier in Muscat.
The ordering string is built from fixed positions. The manufacturer’s example is 8732EM T 1 A 1 K5 DA1 AX M4 C1 GM V2 Q4 HR7 RT05, which reads as follows.
| Code position | Meaning |
|---|---|
| 8732EM | Base model, field-mount transmitter |
| T / R | T = integral mount on the sensor; R = remote field mount (zinc-plated carbon steel bolts and 304L bracket) |
| 1 / 2 / 3 / 4 | Supply: 1 = 90 to 250 Vac; 2 = 12 to 42 Vdc; 3 = low-power 12 to 30 Vdc; 4 = 20 to 32 Vdc for EtherNet/IP only |
| A / B / F / M / E | Output: A = 4–20 mA HART plus pulse; B = intrinsically safe 4–20 mA HART plus I.S. pulse; F = FOUNDATION Fieldbus (FISCO) plus pulse; M = Modbus RS-485 plus pulse; E = EtherNet/IP plus pulse |
| 1 / 2 / 4 / 5 | Conduit: 1 = ½-14 NPT; 2 = M20 x 1.5; 4 and 5 = the same threads with one additional entry |
| Options | Approvals (N5, K5, N1, K1, K7 and others), DA1/DA2 diagnostics, AX discrete channels, M4/M5 display, cable kits RTxx/RHxx/RCxx/RSxx, V2 marine paint, Q4 calibration certificate, HR7 HART revision 7 |
8732EM technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Rosemount (Emerson) 8732EM |
| Sensor compatibility | Rosemount 8705, 8711 and 8721 sensors; AC and DC powered sensors of other manufacturers |
| Coil drive current | 500 mA |
| Flow velocity range | 0.04 to 39 ft/s (0.01 to 12 m/s), forward and reverse, adjustable full scale to ±12 m/s |
| Minimum liquid conductivity | 5 µS/cm |
| Power supply | 90 to 250 Vac 50/60 Hz; 12 to 42 Vdc; 12 to 30 Vdc (HART or Modbus only); 20 to 32 Vdc (EtherNet/IP only) |
| Power consumption | 40 VA max (AC); 15 W max (12–42 Vdc); 3 W max HART or 4 W max Modbus (low power); 18 W max EtherNet/IP |
| System accuracy with 8705-M | ±0.25% of rate (standard), ±0.15% of rate optional high accuracy |
| Pulse output | 0 to 10,000 Hz, pulse width 0.1 to 650 ms, internal up to 12 Vdc or external 5 to 28 Vdc |
| Ambient temperature | –50 to +60 °C without display; –20 to +60 °C with LOI/display; EtherNet/IP –20 to +55 °C |
| Humidity | 0 to 95% RH up to 60 °C |
| Enclosure | Low-copper aluminium, Type 4X, IP66/67/68/69; optional unpainted 316/316L housing (code SH) |
| Weight | About 3.2 kg aluminium, about 10.5 kg stainless steel; add 0.5 kg for display |
How the 8732EM measures flow
Magnetic flow metering follows Faraday’s law: a conductive liquid crossing a magnetic field generates a voltage proportional to its velocity. The transmitter energises the sensor coils with a 500 mA drive current, picks up the small electrode voltage and converts it into a flow rate using the calibration number stamped on the sensor nameplate. Because no part of the sensor protrudes into the stream, there is no pressure drop beyond the pipe bore itself, and the reading does not depend on density, viscosity or temperature of the liquid, provided the liquid is conductive enough.
The basic diagnostics are built in: ground and wiring fault, tunable empty pipe, reverse flow, coil circuit fault, electronics temperature and transmitter self-test. Option DA1 adds high process noise detection and electrode coating detection, while DA2 adds SMART Meter Verification, which can be run on command or continuously, and a 4–20 mA loop verification with HART output. Three independent totalizers, damping up to 256 s and a low flow cut-off adjustable between 0.01 and 11.7 m/s complete the signal conditioning.
Where the 8732EM fits and related Rosemount parts
The 8732EM is the field-mount member of the platform; the wall-mounted partner is the 8712EM with a 15-button keypad, and the sensors are the 8705-M flanged, 8711-M/L wafer and 8721 hygienic types. In an integral installation the sensor and transmitter are ordered together and the sensor calibration number is already matched. In a remote installation the transmitter is connected through a coil cable and an electrode cable, or through a single combination cable, supplied as a kit (RTxx, RHxx, RCxx or RSxx) with lengths from 10 ft up to 500 ft. Related catalog items on our site include the 8700 series magnetic flowmeter, the 8750W sensor family and the Rosemount 8800D vortex meter for non-conductive or steam duties.
Selection and ordering checklist for 8732EM
- Confirm the liquid is conductive, 5 µS/cm or more; a hydrocarbon or distilled product needs a different technology.
- Choose integral or remote mount; remote mount is needed if the sensor will be submerged (IP68 requires a remote transmitter) or sits in a hot or vibrating location.
- Match the supply: AC mains, 24 Vdc, or the low-power DC version, which limits the line size to 10 in. and reduces accuracy to 1% of rate.
- Pick the output the control system reads: HART, FOUNDATION Fieldbus, Modbus RS-485 or EtherNet/IP. EtherNet/IP is not available with hazardous-area or two-entry conduit codes.
- Select the hazardous-area code (for example K5 explosion-proof, K1 ATEX flameproof with increased safety, K7 IECEx) against the plant classification.
- Decide on DA1/DA2 diagnostics, the AX discrete channels, the LOI display and the cable kit length before ordering.
Installation, commissioning and maintenance of the 8732EM
Mount the sensor in a full pipe with a minimum of five straight diameters upstream and two downstream of the electrode plane, and make sure the process fluid is grounded: use grounding rings, a reference electrode or lining protectors as the application requires. Earth the transmitter to the plant earth, kept separate from the process reference ground. Before any welding on the pipe, remove all electrical connections from sensor and transmitter. Enter the 16-digit sensor calibration number, set the pipe size and span, then run the empty-pipe and grounding diagnostics during commissioning. The quick start guide states a five-minute warm-up to rated accuracy after power-up.
Maintenance is mostly electrical: check cable glands and cover O-rings, inspect for moisture at the terminals, and keep spare AC or DC fuses (2 A quick-acting for AC, 3 A for DC). Do not connect a Rosemount transmitter to a non-Rosemount sensor in an Ex area, and do not rub non-metallic labelled units with a dry cloth because of electrostatic charge.
Typical applications in Oman and the GCC
Magnetic transmitters of this class are used on seawater intake and brine lines in desalination plants, cooling-water circuits in power stations, produced and injection water in oil and gas fields, effluent and sewage treatment, and chemical dosing duties in petrochemical sites. The –50 to +60 °C ambient range, IP66/67 enclosure and optional offshore marine paint (V2) suit exposed outdoor installations with heat, dust and salt air. Abrasive slurries are normally kept to 0.9 to 3.1 m/s and clean liquids to 0.6 to 6.1 m/s, according to the platform sizing guide.
8732EM output and power options compared
| Option | Notes |
|---|---|
| A, 90–250 Vac | Standard plant instrument with HART; 4–20 mA is internally or externally powered, 24 Vdc, 500 ohm max loop |
| B, I.S. outputs | Intrinsically safe loop, externally powered, |
| F, FOUNDATION Fieldbus | FISCO segment with AI, PID, arithmetic and integrator blocks |
| M, Modbus | RS-485, 1,200 baud to 115.2 kbaud |
| E, EtherNet/IP | 10/100 Mb, DHCP, embedded web server, EDS download; 20 to 32 Vdc only |
Information to send with an RFQ for 8732EM
- Full model code or the options above, including mounting style, supply, output and conduit thread.
- Sensor type and size if you need a complete flow meter (8705, 8711 or 8721), with liner, electrode material and flange rating.
- Process liquid, conductivity, temperature, pressure and flow range in m3/h.
- Hazardous-area classification and required certificate scheme.
- Cable length for remote mounting and the control system protocol.
- Quantity and delivery site in Oman or the GCC.
Documents and quotation
A manufacturer quick start guide for the 8732EM with HART protocol is attached on this page. Send us the model code and we will confirm availability and any further documents for your 8732EM requirement.
Datasheets & Documents
- Manual Rosemount 8732EM Quick Start Guide (HART) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
| Established | 1956, Minnesota, USA, as Rosemount Engineering Company |
|---|---|
| Founders | Frank D. Werner, Robert E. Keppel and Vernon H. Heath |
| Ownership | Acquired by Emerson in 1976; now an Emerson brand |
| Product families | Pressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments |
Milestones
- 1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
- 1969: The Rosemount 1151 analog pressure transmitter is introduced.
- 1976: Emerson acquires Rosemount.
- 1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
- 2001: The 3051S generation follows.
Rosemount products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure transmitters | 3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm seals | Pressure, differential pressure and remote seal measurement |
| DP flow and DP level | 3051CF flowmeter, 3051L, 3051SAL | Flow through primary elements, and level in pressurised vessels |
| Temperature | 644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-input | Process temperature, high-density multipoint and tank temperature |
| Radar and level | 5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gauges | Level in tanks, separators and custody transfer tank gauging |
| Level switches | 2120, 2140, 2160 wireless, 702 discrete transmitter | High and low level alarms, overfill protection and pump protection |
| Flowmeters | 8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquid | Water, steam and gas flow, and fiscal gas and liquid metering |
| Liquid analysis | 396P TUpH, 396PVP, 499ACL chlorine sensor | pH, ORP and free chlorine in water and process streams |
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 8732EM Field Mount Magnetic Flow
Answers from our engineering team on installation, compatibility and integration.
01What is the Rosemount 8732EM?
It is the field-mount transmitter of the Rosemount 8700M magnetic flow meter platform. It can be mounted on the sensor or remotely, and supports HART, FOUNDATION Fieldbus, Modbus and EtherNet/IP outputs.
02Which sensors work with the 8732EM?
It works with Rosemount 8705, 8711 and 8721 sensors, and with AC or DC powered sensors of other manufacturers. The 8705-M and 8711-M/L are interchangeable with the 8712EM and 8732EM using the sensor calibration number.
03What accuracy does the 8732EM system reach?
With an 8705-M sensor the standard system accuracy is 0.25% of rate, with an optional 0.15% of rate high-accuracy calibration. The low-power version is limited to 1% of rate.
04What power supplies are available?
Code 1 is 90 to 250 Vac, code 2 is 12 to 42 Vdc, code 3 is low-power 12 to 30 Vdc and code 4 is 20 to 32 Vdc for EtherNet/IP only.
05What is the minimum conductivity?
The process liquid must have a conductivity of 5 microsiemens per centimetre or more for the 8732EM and the 8705, 8711 and 8721 sensors.