Endress+Hauser Prowirl D 200 Wafer Vortex Flowmeter

Description

Prowirl D 200 wafer vortex flowmeter for steam, gas and liquid

The Endress+Hauser Prowirl D 200 is a flangeless, wafer-style vortex flowmeter for steam, gases and liquids in pipes from DN 15 to DN 150 (1/2 to 6 in). The meter body is a stainless cast tube only 65 mm (2.56 in) long, clamped between the pipe flanges, which makes it a practical one-to-one replacement for an orifice plate and a light, low-cost choice for basic duty. It is offered with the Proline 200 transmitter as a compact or remote version. Seven Star LLC supplies Endress+Hauser flow instruments in Oman and the GCC as an independent supplier in Muscat, and this page describes the Prowirl D 200 for enquiry preparation.

The model name stands for a family of order codes. The sensor version (volume, high-temperature volume, or mass with temperature), the DSC sensor material, the seal, the pressure class, the housing and the output decide the actual device.

Prowirl D 200 technical specifications

Parameter Specification
Manufacturer / part number Endress+Hauser / Proline Prowirl D 200 (vortex flowmeter, product root 7D2C)
Measuring principle Vortex (Karman vortex street) with capacitance DSC sensor
Nominal diameter DN 15 to 150 (1/2 to 6 in), wafer (disc) style
Face-to-face length 65 mm (2.56 in), no flanges
Flow range, liquids From 0.06 to 4.9 m³/h (DN 15) up to 6.7 to 545 m³/h (DN 150)
Flow range, gas and steam From 0.3 to 25 m³/h (DN 15) up to 33 to 7,262 m³/h (DN 150)
Volume flow accuracy Liquids < 0.75 %; gas and steam < 1.0 % of reading (Re above 20,000)
Mass flow accuracy Water < 0.85 %; saturated steam < 1.7 %
Medium temperature Standard sensor –40 to +260 °C; high-temperature and mass versions –200 to +400 °C
Pressure ratings PN 10/16/25/40, Class 150/300, JIS 10K/20K (wafer flange mating)
Materials Measuring tube stainless cast steel CF3M / 1.4408; DSC sensor 316L wetted parts, optional Alloy C22; compliant with NACE MR0175 and MR0103
Sensor seals Graphite, Viton, Gylon, Kalrez (temperature limits per option)
Outputs 4–20 mA HART (passive), second 4–20 mA, pulse/frequency/switch output; FOUNDATION Fieldbus; PROFIBUS PA; PROFINET and Modbus TCP over Ethernet-APL
Supply voltage Terminal voltage from 12 V DC (HART) or 9 V DC (fieldbus) upward; limits per output option
Ambient temperature Compact, non-hazardous area –40 to +80 °C; lower upper limits apply in Ex versions
Degree of protection IP66/67 (Type 4X)
Functional safety SIL 2 (single channel) and SIL 3 (redundant) flow monitoring with option LA

How the Prowirl D 200 vortex principle works

Fluid flowing past the bluff body in the meter tube sheds vortices alternately from each side. Each vortex creates a small local pressure change, which the capacitive DSC sensor detects and turns into pulses. The shedding frequency is proportional to volume flow, and the proportionality (the K-factor) is fixed by geometry and set at the factory, so it does not drift over time. For Reynolds numbers above 20,000 the K-factor is independent of density and viscosity and of whether the fluid is steam, gas or liquid. There are no moving parts, so there is nothing to maintain in operation.

The DSC sensor is burst-tested, vibration-tested and tested against thermal shock of 150 K/s, which is why this principle copes with water hammer and the temperature swings of a steam line. With the mass versions, a Pt 1000 temperature sensor in the paddle supplies saturated-steam mass flow, energy flow and heat-flow difference without a second instrument.

Sensor versions on the Prowirl D 200

Version Description Temperature range
AA Volume; 316L sensor and tube (Alloy C22 options AB, AC) –40 to +260 °C
BA Volume, high-temperature; 316L –200 to +400 °C
CA Mass with integrated temperature measurement; 316L –200 to +400 °C

Version AA reports volume flow, and mass flow only under constant process conditions with a fixed density entered. CA adds temperature and calculates corrected volume flow, mass flow, saturated-steam pressure, energy flow, heat-flow difference, specific volume and degrees of superheat. Choose it for wet or saturated steam where temperature compensation is enough.

Where Prowirl D 200 fits among Prowirl models

The Prowirl D 200 is the wafer, no-flange member of the Prowirl 200 range. Prowirl F 200 provides a flanged body, Prowirl R 200 has a built-in line-size reduction for low flow, and Prowirl O 200 is built for high-pressure mating pipes with flanged and butt-weld connections up to Class 1500. Choose the Prowirl D 200 when the pipe is DN 150 or smaller, when installation space is limited and when pressure is within PN 40 or Class 300. For higher pressure see the Prowirl O 200 page.

Selecting and ordering the Prowirl D 200

  • Fluid and state: saturated or superheated steam, gas or liquid, with temperature and pressure at normal and maximum flow.
  • Size: select the nominal diameter from the flow range; very low flows may need a smaller bore or a reducer.
  • Sensor version: volume only, high-temperature volume, or mass with integrated temperature.
  • Material: 316L standard; Alloy C22 versions for aggressive fluids; seal as per temperature (graphite to +400 °C, Viton to +175 °C, Kalrez to +275 °C, Gylon to +260 °C).
  • Mating flange: EN, ASME or JIS pressure class so that the right centering rings and mounting set are supplied.
  • Housing: coated aluminum GT20 or stainless GT18 (316L), compact or remote.
  • Output and bus, hazardous-area approval and need for SIL.

Installation, commissioning and maintenance of the Prowirl D 200

Install the wafer body between pipe flanges using the supplied centering rings and the mounting set of tie rods, seals, nuts and washers, and align the flow arrow. Vortex meters need a fully developed profile, so keep straight lengths upstream and 5 x DN downstream; the technical information lists about 15 x DN after a reduction, 20 x DN after a single elbow, 25 x DN after a double elbow and 40 x DN after a three-dimensional double elbow, and the longest figure applies where several disturbances exist. For liquids in a vertical pipe use upward flow. For steam or fluids at 200 °C and above, install with the transmitter head at the side or below, and for very cold fluids, head up or at the side.

Commissioning uses the Make-it-run wizards on the display or FieldCare. Heartbeat Verification can be ordered to document the device in place. Spare parts are normally the sensor seals and the electronics modules, and settings are saved in an integrated memory.

Typical applications in Oman and the GCC

Steam is used widely in Gulf refineries, petrochemical units, food plants and district cooling, and the Prowirl D 200 is a natural fit for steam headers, condensate returns, compressed air and nitrogen lines, hot oil and thermal-fluid circuits, and cooling-water systems. Because the meter is flangeless and light, it suits packaged boilers, skids and utility rooms where space is tight. In hot Omani sites, check the ambient limit of the chosen housing and approval class, and shade the transmitter on outdoor lines.

Information to send with an RFQ for the Prowirl D 200

  • Fluid, state, normal and maximum flow, temperature and pressure.
  • Pipe nominal diameter, schedule and mating flange standard and class.
  • Mass flow or energy flow requirement, with or without pressure compensation.
  • Output or fieldbus, hazardous area and SIL requirement.
  • Compact or remote housing and cable length for remote versions.

Documents and quotation

The manufacturer technical information for the Prowirl D 200 is attached to this page as a datasheet and should be read with the operating instructions and your line specification.

Seven Star LLC quotes against the full order code or your duty sheet, and confirms availability, delivery to Oman and the GCC and the certificates provided with the shipment.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser Prowirl D 200 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser Prowirl D 200 Wafer Vortex Flowmeter

Answers from our engineering team on installation, compatibility and integration.

01What is the Prowirl D 200?
It is a wafer-style vortex flowmeter from DN 15 to DN 150 for steam, gas and liquid, with a 65 mm face-to-face length and no flanges. It is fitted between the pipe flanges.
02What accuracy does it offer?
Volume flow accuracy is below 0.75 % of reading for liquids and below 1.0 % for gas and steam above Reynolds number 20,000. Mass flow of saturated steam is below 1.7 %, and water mass flow is below 0.85 %.
03Can the Prowirl D 200 replace an orifice plate?
Yes, the manufacturer lists a one-to-one replacement of orifice plates as an application. The meter body is short, but straight inlet and outlet runs must still be respected for accuracy.
04What fluid temperatures are covered?
The standard sensor covers –40 to +260 °C. High-temperature and mass versions cover –200 to +400 °C, depending on the seal selected.
05Which outputs are available?
Options include 4–20 mA HART, a second 4–20 mA output, pulse/frequency/switch output, FOUNDATION Fieldbus, PROFIBUS PA, and PROFINET or Modbus TCP over Ethernet-APL.