- Automation & ControlView all 1,670 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Isolator & Barrier
- Servo Drives
- HMI Displays
- Motor Soft Starters
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Rosemount
Rosemount 3051SFC Compact Orifice Flow Meter
Description
Rosemount 3051SFC compact orifice flow meter between existing flanges
The Rosemount 3051SFC is a compact differential pressure flow meter: a 316 stainless steel orifice plate or conditioning orifice plate, a manifold head and a Rosemount 3051S transmitter delivered as one fully configured, leak-tested unit. It fits between two raised-face flanges, so it can often replace an old orifice run without cutting pipe. Line sizes run from 1/2 in. (15 mm) to 12 in. (300 mm), and the meter reports compensated mass flow directly when a measurement type with flow calculation is selected.
Seven Star LLC supplies Rosemount flow instrumentation in Oman and the GCC as an independent supplier in Muscat. This page explains the 3051SFC code structure, its performance by plate type, and what to prepare for a quotation.
Reading a 3051SFC model code
The manufacturer gives a typical code, 3051SFC 1 C S 060 N 065 T 3 2 J A 1A 3. Reading it in order against the ordering tables gives the following.
| Code in example | Meaning |
|---|---|
| 3051SFC | Compact flow meter |
| 1 | Measurement type 1: fully compensated mass and energy flow (DP, static pressure and temperature) |
| C | Primary element technology: conditioning orifice plate (P is plain orifice plate) |
| S | Material: 316 SST |
| 060 | Line size: 6 in. (150 mm) |
| N065 | Primary element type: beta ratio 0.65 |
| T | Temperature measurement: integral RTD |
| 3 | Transmitter connection: direct mount with integral 3-valve manifold |
| 2 | Differential pressure range 2: 0 to 250 inH2O |
| J | Static pressure: gauge, –14.2 to 800 psig |
| A | Output: 4–20 mA with HART |
| 1A | Housing: Plantweb, aluminum, 1/2–14 NPT |
| 3 | Performance class: Ultra for Flow |
3051SFC technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Rosemount 3051SFC Compact Orifice Flow Meter |
| Primary element | Conditioning orifice plate (C) or orifice plate (P), 316/316L SST body and plate |
| Line sizes | 1/2 in. to 12 in. (15 to 300 mm); 1/2, 1 and 1-1/2 in. with the plain orifice only |
| Beta ratios | 0.40, 0.50, 0.65 (0.60 for the 2 in. conditioning orifice) |
| Straight run | Conditioning orifice needs 2D upstream and 2D downstream from most disturbances |
| Flow accuracy, conditioning orifice, Ultra for Flow | ±0.75 % of flow rate (beta 0.40) or ±1.15 % (beta 0.50, 0.65) at 14:1 turndown |
| Flow accuracy, orifice plate, Ultra for Flow | ±1.30 % of flow rate at 14:1 turndown (add 0.5 % outside 2–8 in.) |
| Classic MV accuracy | ±1.10 % (beta 0.40) / ±1.45 % (beta 0.50, 0.65) / ±1.45 % (orifice) at 8:1 |
| Process temperature, direct mount | –40 to 450 °F (–40 to 232 °C) |
| Process temperature, remote mount | –321 to 850 °F (–196 to 454 °C) |
| Wetted parts | 316/316L SST body and plate, 50 micro-inch Ra finish; 316 SST manifold head and valves |
| DP ranges | 0–25, 0–250, 0–1000 inH2O |
| Output options | 4–20 mA HART, FOUNDATION Fieldbus, WirelessHART |
| Vibration limit (structural) | IEC 61298-3 general field; transmitter assembly not above 9 lb (4.08 kg) and 8.60 in. (218.44 mm) long |
Ultra for Flow performance (code 3) is only available with DP ranges 2 and 3 and silicone fill fluid. Range 1 meters carry an extra uncertainty of up to 0.9 %, so confirm the range with the sizing tool.
Why the 3051SFC conditioning orifice shortens the piping
A conventional orifice plate needs long, undisturbed pipe on both sides. The conditioning plate shapes the velocity profile before the measurement, which is why the manufacturer states two diameters upstream and two downstream for most disturbances, and a discharge coefficient uncertainty as low as 0.5 percent. The plain orifice version follows the usual flow-through-a-single-bore principle for cases where piping is already long and clean.
Both versions measure the pressure drop across the plate with the 3051S module. Measurement types 1 to 4 carry the flow calculation inside the transmitter, so there is no separate flow computer on the loop. Types 5 to 7 give process variables only, and type D gives differential pressure.
3051SFC selection and ordering checklist
- Fluid and phase: liquid, gas or steam, with density, viscosity and operating conditions.
- Flow range and the beta ratio chosen from the sizing tool, so the plate is made for your minimum and maximum flows.
- Line size and flange standard; 10 in. and 12 in. meters require an alignment ring (ANSI Class 150, 300, 600, DIN PN16, 40, 100 or JIS).
- Plate type: conditioning orifice or orifice plate; conditioning orifice flow calibration of 3 or 10 points is optional.
- Temperature element: integral RTD, remote thermowell or none; needed for measurement types 1, 3, 5 and 7.
- Direct or remote transmitter mounting, DP range, static pressure range and output protocol.
- Housing, approvals, NACE compliance, hydrostatic test and inspection certificates.
Installing the 3051SFC between flanges
The meter is clamped between two raised-face flanges with customer-supplied studs, nuts and gaskets. The manufacturer recommends Durlon 8500 fibre gaskets and advises replacing gaskets and O-rings whenever the primary element is taken apart. Studs and nuts are available as spare parts. Ensure the plate is concentric with the pipe, which the alignment ring helps with on large sizes.
For vibration, the manufacturer notes performance of better than ±0.1 percent of URL when tested per IEC 60770-1, but the weight and length limits of the transmitter assembly must be respected. A 3-valve manifold supports zero checks in service, and a graphite valve packing option exists for high-temperature use up to 850 °F.
Related 3051SF meters and the Rosemount 405 element
The Rosemount 405 is the stand-alone compact primary element described in the same product data sheet. In the 3051SF family the neighbours are the 3051SFA for large lines, where an Annubar averaging pitot is more economical, and the 3051SFP for lines of 1/2, 1 and 1-1/2 in. with a precision honed pipe section. The 3051SFC fills the middle range of line sizes in a flanged installation.
3051SFC applications in Oman and the GCC
Typical duties are fuel gas and instrument air headers, boiler feedwater and steam lines in power plants, chemical dosing and cooling water in desalination, and process gas or condensate in oil and gas facilities. The compact form is attractive on busy pipe racks where long upstream runs are impossible. Heat in the Gulf summer is handled by checking process temperature against the 450 °F direct-mount limit and using remote mount if the transmitter would see high radiant heat.
Information to send with a 3051SFC RFQ
- Sizing sheet or line data: fluid, pressure, temperature, flow range and pipe schedule.
- Plate type, beta ratio and measurement type.
- Flange standard and class, and alignment ring needs for 10 and 12 in.
- Transmitter connection, ranges, output, housing and approvals.
- Calibration or certificates required, quantity and delivery site.
Documents and quotation
The manufacturer product data sheet for the Rosemount DP flow meters and primary elements is attached on this page. It covers the 3051SFC ordering tables, accuracy by plate type and temperature limits.
To request a quotation, send the model code or the process data. Seven Star LLC will review the configuration and reply with availability for Oman and the GCC.
Other Models in the Rosemount 3051sf Dp Flow Range
Seven Star LLC supplies models from the Rosemount 3051sf Dp Flow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rosemount 3051SFA Annubar Flow Meter | Flowmeters | View details |
| Rosemount 3051SFC Compact Orifice Flow Meter | Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Rosemount DP Flow Meters and Primary Elements Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
| Established | 1956, Minnesota, USA, as Rosemount Engineering Company |
|---|---|
| Founders | Frank D. Werner, Robert E. Keppel and Vernon H. Heath |
| Ownership | Acquired by Emerson in 1976; now an Emerson brand |
| Product families | Pressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments |
Milestones
- 1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
- 1969: The Rosemount 1151 analog pressure transmitter is introduced.
- 1976: Emerson acquires Rosemount.
- 1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
- 2001: The 3051S generation follows.
Rosemount products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure transmitters | 3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm seals | Pressure, differential pressure and remote seal measurement |
| DP flow and DP level | 3051CF flowmeter, 3051L, 3051SAL | Flow through primary elements, and level in pressurised vessels |
| Temperature | 644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-input | Process temperature, high-density multipoint and tank temperature |
| Radar and level | 5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gauges | Level in tanks, separators and custody transfer tank gauging |
| Level switches | 2120, 2140, 2160 wireless, 702 discrete transmitter | High and low level alarms, overfill protection and pump protection |
| Flowmeters | 8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquid | Water, steam and gas flow, and fiscal gas and liquid metering |
| Liquid analysis | 396P TUpH, 396PVP, 499ACL chlorine sensor | pH, ORP and free chlorine in water and process streams |
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 3051SFC Compact Orifice Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What is the Rosemount 3051SFC?
It is a compact orifice flow meter that integrates a 3051S transmitter, manifold and orifice plate. It installs between two raised-face flanges and can report compensated mass flow.
02What is the difference between the C and P versions of the 3051SFC?
C is a conditioning orifice plate that needs only 2D upstream and 2D downstream piping from most disturbances. P is a plain orifice plate and is the only option for 1/2, 1 and 1-1/2 in. lines.
03What accuracy does the 3051SFC reach?
With Ultra for Flow, the conditioning orifice states ±0.75 % of flow rate at beta 0.40 and ±1.15 % at beta 0.50 or 0.65, over 14:1 turndown. The plain orifice states ±1.30 %.
04What temperature range does the 3051SFC support?
A direct-mount meter is rated from –40 to 450 °F (–40 to 232 °C). A remote-mount meter extends this from –321 to 850 °F (–196 to 454 °C).
05Is an alignment ring needed for the 3051SFC?
It is required for 10 in. (250 mm) and 12 in. (300 mm) line sizes and is selected by flange standard and class. Smaller sizes do not require it according to the ordering table.


















Reviews