AMETEK 7002-426-TE overview

AMETEK 7002-426-TE is the hotwire combustibles detector kit for the Thermox WDG-V analyzer. The AMETEK listing states that it replaces the earlier number 7000-816-TE, which still appears in the WDG-V user manual spare parts table as the hot wire detector kit. That numbering change is exactly why buyers search for both numbers and why a plant with an older manual needs a clear cross-reference. The kit is for analyzers fitted with the hot wire type of combustibles detector rather than the RTD type.

The Thermox WDG-VC measures excess oxygen and combustibles (CO plus H2) in flue gas, and the WDG-VCM adds methane. The datasheet states that the analyzers are SIL 2 compliant for excess oxygen and for combustibles with the RTD catalytic detector, and capable for use in SIS combustion safety systems. The combustibles range is 0-500 ppm to 0-10,000 ppm with 0-2000 ppm as standard.

Key features of 7002-426-TE

  • Hotwire combustibles detector kit for the WDG-V family
  • AMETEK listing states it replaces 7000-816-TE
  • Wires: black to Cact and brown to Cref for hot wire detectors
  • Held by two 4.0 mm hex screws in the heater block
  • Fitted with a new o-ring per the manual
  • RTD version is a separate part, 7000-815-TE

7002-426-TE technical specifications

Item Detail
Part number 7002-426-TE
Description Kit, hotwire combustibles detector, WDG-V
Replaces 7000-816-TE (per AMETEK listing)
Detector type Hot wire catalytic bead type
Wiring Black wires to Cact, brown wires to Cref
Mounting Two 4.0 mm hex screws on the heater block
Principle (datasheet) Zirconium oxide for O2, catalytic detectors for combustibles
O2 output range 0-1 percent to 0-100 percent
Combustibles range 0-500 ppm to 0-10,000 ppm, 0-2000 ppm standard
Combustibles accuracy Plus or minus 2 percent of full scale or plus or minus 40 ppm, whichever is greater
Combustibles response 90 percent of a step change in under 25 seconds with flame arrestors
Outputs Three isolated linear current outputs, five alarms, Modbus RTU
Max sample dew point 200 degrees C (392 degrees F)
Enclosure Hinged IP65 (NEMA 4X) stainless steel

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 7002-426-TE. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

The datasheet lists process heaters, steam boilers and thermal oxidizers, serving refining and petrochemical, power and steam generation, and furnaces and boilers. In Oman and the GCC the combustibles measurement is valued on fired heaters and boilers where a rise in CO plus H2 signals incomplete combustion and an excess-oxygen measurement alone is not enough for burner management.

Where 7002-426-TE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 7002-426-TE

Confirm whether the analyzer is a WDG-VC (combustibles) or WDG-VCM (combustibles and methane), and whether it uses an RTD or hot wire combustibles detector, because the detector type changes the kit, the wiring colours and the main processor board.

Part number 7002-426-TE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Disconnect the combustibles detector wires from the Cact and Cref terminals on the sensor board. For hot wire detectors the manual states that the black wires go to Cact and the brown wires go to Cref. Remove the two 4.0 mm hex screws and withdraw the old detector, keeping the screws. Use a new o-ring, align 7002-426-TE on the two screw positions, tighten until the face is flush with the block and the gasket is fully compressed, and reconnect the leads. Be careful not to damage the detector element ends during insertion.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 7002-426-TE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

Do not confuse hot wire and RTD detectors: the main processor board also differs, because the manual lists separate processor boards for the RTD and hot wire versions. Confirm which version is installed before ordering 7002-426-TE.

Related products and ordering notes

Compare with 7000-815-TE for RTD analyzers and with 7001-226-TE and 3000-337-JE for the block and o-ring.

For a spare parts plan, list 7002-426-TE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Process plants in Oman and the wider GCC run long between shutdowns, which is why maintenance planners check part numbers early and hold critical spares. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We source against the exact number you give us and confirm availability and lead time before you commit.

Frequently asked questions about 7002-426-TE

  • What is AMETEK 7002-426-TE? It is the hotwire combustibles detector kit for the Thermox WDG-V, and the AMETEK listing states that it replaces 7000-816-TE.
  • Is 7002-426-TE for RTD detectors? No. RTD analyzers use 7000-815-TE. 7002-426-TE is for analyzers fitted with the hot wire combustibles detector.
  • Which wires connect to Cact on 7002-426-TE? The manual says the black wires go to Cact and the brown wires go to Cref for hot wire detectors.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 7002-426-TE, send the RFQ with the part number 7002-426-TE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK WDG-VC Combustion Flue Gas Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 7002-426-TE WDG-V Hotwire Combustibles

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 7002-426-TE?
It is the hotwire combustibles detector kit for the Thermox WDG-V, and the AMETEK listing states that it replaces 7000-816-TE.
02Is 7002-426-TE for RTD detectors?
No. RTD analyzers use 7000-815-TE. 7002-426-TE is for analyzers fitted with the hot wire combustibles detector.
03Which wires connect to Cact on 7002-426-TE?
The manual says the black wires go to Cact and the brown wires go to Cref for hot wire detectors.
04Does an older manual show 7000-816-TE?
Yes. The WDG-V manual spare parts table shows 7000-816-TE for the hot wire detector kit, and the AMETEK listing now gives 7002-426-TE as its replacement.
05How do I request a quotation for 7002-426-TE?
Send the part number 7002-426-TE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.