Siemens Maxum II Filament Detector 2-Cell Assembly 2021335-001

Description

Overview: A Concentration-Response Detector for General Analysis

The Siemens Maxum II Filament Detector 2-Cell Assembly, part number 2021335-001, is a complete two-cell filament thermal conductivity detector (TCD) module for the Siemens Maxum Edition II process gas chromatograph. This assembly is the current-generation replacement for the earlier 2021122-001 2-cell filament detector kit, providing concentration-response detection suited to a broad range of process components with moderate sensitivity requirements, and can also serve as an inter-column detector (ITC) in configurations paired with an FID or FPD application.

As an independent specialized supplier of Siemens Maxum Edition II analyzer spare parts, Seven Star LLC sources and supplies the filament detector assembly 2021335-001 to refineries, gas plants, and petrochemical complexes across Oman and the wider GCC. Keeping the correct current-generation assembly in stock helps maintenance teams avoid compatibility issues that arise from ordering the discontinued 2021122-001 kit.

Working Principle: Thermal Conductivity Detection

The 2-cell filament TCD operates on the principle of differential thermal conductivity measurement: two heated filament elements are exposed to carrier gas flow, one acting as a reference cell and the other as a measurement cell through which the column effluent passes. As sample components elute from the separation column and mix with the carrier gas, they alter the thermal conductivity of the gas stream passing over the measurement filament, changing its rate of heat loss and therefore its electrical resistance relative to the reference filament.

This resistance difference is measured using a Wheatstone-bridge-type circuit and converted into an electrical signal proportional to the concentration of the eluting component, giving the TCD its characteristic universal, concentration-response behavior – it responds to virtually any component whose thermal conductivity differs from the carrier gas, rather than being limited to hydrocarbons or sulfur compounds as with flame-based detectors. This makes the 2-cell filament detector well suited to general-purpose analysis and to serving as an inter-column detector supporting a companion FID or FPD detector elsewhere in the same analyzer.

Engineering Design of the Filament Detector Assembly

The 2021335-001 assembly is supplied as a complete detector module engineered for direct installation into the Maxum Edition II detector compartment, connecting to the Detector Personality Module (DPM) through the analyzer’s standard feed-through assembly. The filament elements are precision-matched to maintain balanced reference and measurement cell characteristics, which is essential to accurate, drift-free thermal conductivity measurement over the detector’s service life.

Because the filament board within the TCD housing is a serviceable item, the assembly is designed so that the filament/thermistor board can be replaced without disturbing the surrounding oven plumbing in many cases, though the detector must always be fully de-energized before opening per standard safety procedure. The 2-cell configuration keeps the detector compact enough to fit within the Maxum II’s air bath or airless oven detector module arrangement alongside other detector types.

Key Features

The Filament Detector 2-Cell Assembly 2021335-001 provides dependable, universal-response detection for the Maxum Edition II platform. Key characteristics include:

  • Complete 2-cell filament TCD assembly, factory-current replacement for the discontinued 2021122-001 kit.
  • Universal concentration-response detection suited to a wide range of process components.
  • Can be configured as an inter-column detector (ITC) alongside an FID or FPD application.
  • Precision-matched filament elements for balanced, drift-free reference and measurement cell performance.
  • Compatible with both air bath and airless Maxum Edition II oven configurations.
  • Genuine Siemens Maxum II part number for correct fit and DPM compatibility.
  • The only detector type supported by the Maxum II modular oven, which is restricted to thermal conductivity detection.
  • Siemens requires the TCD to be opened only with power removed, and serviced by Siemens-trained maintenance personnel.

Industrial Applications

The 2-cell filament detector is used across general process gas chromatography applications where a broad, universal-response detector is preferred over the more selective flame ionization or flame photometric detectors, including permanent gas analysis, general hydrocarbon and non-hydrocarbon component monitoring, and inter-column detection duties supporting a primary FID or FPD channel in multi-detector analyzer configurations. Its concentration-response nature makes it a practical choice for refinery and gas processing streams containing a wide variety of component types.

Seven Star LLC supports refinery instrumentation teams, gas processing operators, and petrochemical maintenance departments across Oman, Muscat, Sohar, and the broader GCC region with sourcing of Maxum Edition II detector hardware, helping analyzer houses maintain measurement continuity across their full detector configuration.

Platform Context and Operating Envelope

Specifying the Siemens Maxum II Filament Detector 2-Cell Assembly correctly means understanding where it sits within the analyzer. The Maxum edition II accepts thermal conductivity, flame ionization, flame photometric, helium ionization, photoionization and electron capture detection, and the oven type determines how many and which detector modules a given analyzer can carry. An airbath oven working between 5 and 225 °C in isothermal or temperature-programmed mode supports up to three detector modules; an airless oven, which Siemens rates at 0.02 °C isothermal control accuracy, normally carries one or two; and the modular oven, operating between roughly 60 and 80 °C depending on application, supports thermal conductivity detection only. That last point matters at the sourcing stage, because on a modular-oven Maxum the filament TCD is not one option among several, it is the detector.

Siemens specifies carrier gas for the platform as hydrogen, nitrogen, helium, argon or synthetic air from compressed cylinders at 99.999% purity, with consumption of roughly 5 to 100 litres per month per detector module, and rates the analyzer for ambient temperatures of -18 to 50 °C depending on application. Thermal conductivity measuring ranges on gaseous samples extend down to 0 to 20 ppm, with the modular-oven version reaching 0 to 200 ppm, and repeatability is quoted from ±0.5% on spans of 2 to 100% out to ±5% on a 0.5 to 5 ppm range. The analyzer itself is certified for ATEX and IECEx Zone 1 and Zone 2 with air or nitrogen purging, and for CSA Class I Divisions 1 and 2, Groups B to D.

Technical Specifications

The table below summarizes the core specifications of the Siemens Maxum II Filament Detector 2-Cell Assembly as supplied by Seven Star LLC.

Parameter Specification
Model / Part Number Filament Detector 2-Cell Assembly, P/N 2021335-001
Detector Type Thermal Conductivity Detector (TCD), 2-cell filament
Response Type Universal, concentration-response
Optional Role Inter-column detector (ITC) alongside FID or FPD
Supersedes 2021122-001 (discontinued)
Target Platform Siemens Maxum Edition II Process Gas Chromatograph
Host oven compatibility Airbath (5 to 225 °C), airless, and modular (60 to 80 °C) ovens; the modular oven supports thermal conductivity detection only
Carrier gas (platform) Hydrogen, nitrogen, helium, argon or synthetic air, 99.999% purity
TCD measuring range (platform) From 0 to 20 ppm on gaseous samples; 0 to 200 ppm on the modular-oven version
Hazardous area (analyzer) ATEX / IECEx Zone 1 and Zone 2 with purging; CSA Class I Div 1 and 2, Groups B–D
Hardware Condition New, genuine Siemens part number

Request a Quote for Siemens Maxum II Filament Detector 2-Cell Assembly 2021335-001

Seven Star LLC is a dedicated supplier of Siemens Maxum Edition II process gas chromatograph spare parts and detector assemblies throughout Oman and the GCC. To request a formal B2B quotation, verify current availability and lead time, or confirm compatibility of the Filament Detector 2-Cell Assembly 2021335-001 with your specific Maxum II configuration, contact our instrumentation sourcing team today.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Siemens Maxum II Filament Detector 2-Cell Assembly 2021335-001 Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Most Siemens automation parts are bought by article number, the string beginning 6ES7, 6AV2 or 6GK5 printed on every module. Founded in 1847 and headquartered in Munich, Siemens builds the SIMATIC controllers, SCALANCE networks and SINAMICS drives that plant engineers meet on almost every site. Seven Star LLC, an independent supplier, lists Siemens PLC and I/O modules, HMI panels, industrial Ethernet switches, drives, protection relays, temperature transmitters and gas analyzer spare parts for projects in Oman and the GCC.

Siemens product families on this page

Controller hardware covers the SIMATIC S7-1200 (CPU 1214C with SM 1223 signal modules) and the S7-1500 (CPU 1515-2 PN), with ET 200SP and ET 200M distributed I/O and their IM 155-6 and IM 153-2 interface modules. Operator panels include the KTP700 Basic and TP700 Comfort. SCALANCE XC208 managed switches handle industrial Ethernet. Drives are represented by the SINAMICS G120C compact inverter and the G120X for pumps and fans. From the power side come the SIPROTEC 7SJ85 feeder protection relay and SIVACON S8 switchboards, and from process instrumentation the SITRANS TH320 head-mounted temperature transmitter.

Where Siemens equipment is used

SIMATIC controllers and ET 200 I/O run packaged units, skids and whole process lines in water treatment, oil and gas, cement, food and manufacturing plants. SINAMICS drives control pumps, fans and conveyors, SCALANCE switches form the control network, and SIPROTEC relays protect medium voltage feeders and motors.

Ordering Siemens parts: what we need

Send the complete article number, the functional status or version printed on the module and, for CPUs, the firmware version your project was written for. For drives add power, supply voltage, filter option and fieldbus version. For SIPROTEC relays the long order number or product code is required, because it fixes the hardware and function package. A nameplate photo answers most of these points at once.

Frequently Asked Questions

What type of detector is the 2021335-001 assembly?
It is a complete 2-cell filament thermal conductivity detector (TCD), providing universal concentration-response detection rather than the selective response of flame-based detectors.
Does this replace an older part number?
Yes, the 2021335-001 assembly is the current-generation replacement for the earlier, discontinued 2021122-001 2-cell filament detector kit.
Can this detector be used alongside an FID or FPD?
Yes, the 2-cell filament TCD can be configured as an inter-column detector (ITC) working in conjunction with an FID or FPD application within the same analyzer.
What ovens is this detector compatible with?
The 2-cell filament detector assembly is compatible with both air bath and airless Maxum Edition II oven configurations.
Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens Maxum II Filament Detector 2-Cell Assembly 2021335-001 to refinery, gas processing, and petrochemical customers across Oman and the wider GCC region.