Brand:

Siemens Maxum II FID/FPD Flame Arrester Hastelloy-C 1460006-001

Description

Overview: A Critical Safety Component for Detector Venting

The Siemens Maxum II Flame Arrester Hastelloy-C, part number 1460006-001, is a safety-critical fitting used on the Flame Ionization Detector (FID) of the Siemens Maxum Edition II process gas chromatograph. Constructed from corrosion-resistant Hastelloy-C, this arrester threads into the FID bottom body, with its insert tube connecting to a union inside the analyzer oven, to prevent flame propagation out of the detector and back along the analyzer’s tubing – a mandatory protective measure on any combustion-based detector operating continuously in a hazardous-area process environment.

As an independent specialized supplier of Siemens Maxum Edition II analyzer spare parts, Seven Star LLC sources and supplies the flame arrester assembly 1460006-001 to refineries, gas plants, and petrochemical complexes across Oman and the wider GCC. Seven Star LLC helps maintenance teams keep the correct genuine Hastelloy-C arrester in stock to avoid safety-related downtime during FID servicing. Note that the Flame Photometric Detector (FPD II) does not use this part: per the Siemens Maxum Edition II Detectors Service Manual, the FPD takes its exhaust from the combustion chamber through a flameproof joint rather than through a flame arrester, and FPD hardware carries separate Siemens part numbers.

Working Principle: Flame Propagation Prevention

A flame arrester works by forcing the gas stream through a network of narrow passages or a porous matrix with dimensions small enough that heat is dissipated faster than a flame front can propagate through them. On the FID, this principle isolates the hydrogen-fuelled detector flame from the tubing that runs back into the analyzer oven – if a flashback event were to occur inside the detector body, the arrester’s narrow internal geometry quenches the flame before it can travel out of the detector and into the surrounding analyzer enclosure.

The choice of Hastelloy-C construction reflects the corrosive and thermally demanding environment inside an operating FID detector body, where the arrester is exposed to combustion byproducts and sustained elevated temperature. Hastelloy-C’s resistance to oxidation and chemical attack ensures the arrester’s narrow flame-quenching geometry remains dimensionally stable and free of corrosion product buildup over long service intervals, preserving both its safety function and its gas flow characteristics.

Engineering Design of the Flame Arrester Assembly

The 1460006-001 flame arrester is machined to the precise internal tolerances required to provide a certified flame-quenching gas path while introducing minimal restriction to the detector’s normal gas flow. Its compact fitting is sized for direct installation into the FID bottom body, matching the Maxum Edition II’s standard detector plumbing without requiring custom adaptation.

Because this arrester sits directly in the flame path of a continuously operating combustion detector, its mechanical integrity is central to the ongoing safety certification of the analyzer installation. Genuine Siemens-specified Hastelloy-C arrester assemblies are manufactured and tested to maintain their flame-quenching performance across the detector’s full operating temperature range, which is a key reason process safety and instrumentation teams standardize on the correct OEM part number rather than substituting generic flame arrester fittings.

Key Features

The Flame Arrester Hastelloy-C 1460006-001 is engineered to protect Flame Ionization Detector installations on the Maxum Edition II. Key characteristics include:

  • Direct-fit replacement flame arrester insert assembly for the FID detector module on the Maxum Edition II.
  • Hastelloy-C construction for resistance to corrosion and combustion byproduct attack.
  • Precision-machined internal geometry engineered to quench flame propagation with minimal flow restriction.
  • Rated for the sustained elevated temperatures present inside an operating flame detector body.
  • Genuine Siemens Maxum II part number 1460006-001 for correct safety-certified fit.
  • Installs and removes with a 9/16 in open-end wrench, seating against its flat washer in the FID bottom body.

Installation and Replacement on the FID

The Siemens Maxum Edition II Detectors Service Manual identifies the flame arrester as three related items within the FID assembly: the Flame Arrestor Insert Assembly that threads into the narrow end of the FID bottom body, the flat washer that seats beneath it, and the Flame Arrestor Bushing and arrester that complete the assembly. Replacement is a mechanical operation carried out with the detector cooled and the hydrogen supply isolated. Tubing is first disconnected from the FID flame arrestor insert tube inside the oven, after which the insert is removed from the FID bottom body using a 9/16 in open-end wrench.

Reassembly is where most field errors occur. Siemens is explicit that the threads of the FID flame arrestor must be clean and free of lubricant or any other substance before the insert and its washer are placed into the FID bottom body and tightened, because a contaminated thread can compromise the flameproof path that the arrester exists to maintain. The insert tubing is then reconnected to the correct connection union in the oven. Because the Siemens Maxum II Flame Arrester Hastelloy-C is part of the analyzer’s flameproof containment rather than a consumable measuring component, instrumentation teams across Oman and the GCC generally schedule its inspection and replacement into planned detector overhauls and turnaround safety inspections rather than waiting for a symptom to appear.

Industrial Applications

The flame arrester assembly is a required maintenance item wherever a Maxum Edition II analyzer is fitted with an FID, including refinery hydrocarbon monitoring, natural gas quality analysis, and total hydrocarbon measurement on petrochemical process streams. Because it is a safety-critical component, it is typically replaced as part of scheduled detector overhaul and safety inspection intervals rather than only on failure, making reliable stock availability important for planned turnaround maintenance.

Seven Star LLC supports refinery instrumentation teams, gas processing operators, and petrochemical maintenance departments across Oman, Muscat, Sohar, and the broader GCC region with sourcing of this and other Maxum Edition II detector safety hardware, helping analyzer houses maintain both measurement continuity and process safety compliance.

Technical Specifications

The table below summarizes the core specifications of the Siemens Maxum II Flame Arrester Hastelloy-C as supplied by Seven Star LLC.

Parameter Specification
Model / Part Number Flame Arrester Assembly, P/N 1460006-001
Material Hastelloy-C
Function Flame propagation prevention (flashback protection)
Compatible Detector Flame Ionization Detector (FID). Not used on the FPD II, which vents through a flameproof joint
Target Platform Siemens Maxum Edition II Process Gas Chromatograph
Typical Location Detector vent / inlet gas tubing
Hardware Condition New, genuine Siemens part number
Assembly Items (per Siemens FID assembly) Flame Arrestor Insert Assembly, flat washer, Flame Arrestor Bushing, Flame Arrestor
Mounting Threads into the narrow end of the FID bottom body; insert tube connects to an oven union
Service Tool 9/16 in open-end wrench
Installation Requirement Threads must be clean and free of lubricant or other substances
Reference Document Siemens Maxum Edition II Detectors Service Manual, A5E42019847001

Request a Quote for Siemens Maxum II FID/FPD Flame Arrester Hastelloy-C 1460006-001

Seven Star LLC is a dedicated supplier of Siemens Maxum Edition II process gas chromatograph spare parts and detector safety hardware throughout Oman and the GCC. To request a formal B2B quotation, verify current availability and lead time, or confirm compatibility of the Flame Arrester Hastelloy-C 1460006-001 with your FID detector configuration, contact our instrumentation sourcing team today.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Siemens Maxum II FID/FPD Flame Arrester Hastelloy-C 1460006-001 Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Most Siemens automation parts are bought by article number, the string beginning 6ES7, 6AV2 or 6GK5 printed on every module. Founded in 1847 and headquartered in Munich, Siemens builds the SIMATIC controllers, SCALANCE networks and SINAMICS drives that plant engineers meet on almost every site. Seven Star LLC, an independent supplier, lists Siemens PLC and I/O modules, HMI panels, industrial Ethernet switches, drives, protection relays, temperature transmitters and gas analyzer spare parts for projects in Oman and the GCC.

Siemens product families on this page

Controller hardware covers the SIMATIC S7-1200 (CPU 1214C with SM 1223 signal modules) and the S7-1500 (CPU 1515-2 PN), with ET 200SP and ET 200M distributed I/O and their IM 155-6 and IM 153-2 interface modules. Operator panels include the KTP700 Basic and TP700 Comfort. SCALANCE XC208 managed switches handle industrial Ethernet. Drives are represented by the SINAMICS G120C compact inverter and the G120X for pumps and fans. From the power side come the SIPROTEC 7SJ85 feeder protection relay and SIVACON S8 switchboards, and from process instrumentation the SITRANS TH320 head-mounted temperature transmitter.

Where Siemens equipment is used

SIMATIC controllers and ET 200 I/O run packaged units, skids and whole process lines in water treatment, oil and gas, cement, food and manufacturing plants. SINAMICS drives control pumps, fans and conveyors, SCALANCE switches form the control network, and SIPROTEC relays protect medium voltage feeders and motors.

Ordering Siemens parts: what we need

Send the complete article number, the functional status or version printed on the module and, for CPUs, the firmware version your project was written for. For drives add power, supply voltage, filter option and fieldbus version. For SIPROTEC relays the long order number or product code is required, because it fixes the hardware and function package. A nameplate photo answers most of these points at once.

Frequently Asked Questions

Which detectors use the 1460006-001 flame arrester?
The flame arrester assembly 1460006-001 is a common part used on both the Flame Ionization Detector (FID) and the Flame Photometric Detector (FPD II) on the Siemens Maxum Edition II process gas chromatograph.
Why is Hastelloy-C used for this flame arrester?
Hastelloy-C resists oxidation and chemical attack from combustion byproducts and sustained elevated temperature inside an operating flame detector, keeping the arrester dimensionally stable and free of corrosion buildup over long service life.
What safety function does this flame arrester perform?
The arrester forces gas through narrow internal passages that dissipate heat faster than a flame front can travel, quenching any flashback before it can propagate upstream into the analyzer's hydrogen and combustion air supply lines.
Is this a routine maintenance item or only a failure replacement?
Because it is a safety-critical component, the flame arrester is typically replaced as part of scheduled detector overhaul and safety inspection intervals, not only when a fault is detected.
Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens Maxum II Flame Arrester Hastelloy-C to refinery, gas processing, and petrochemical customers across Oman and the wider GCC region.