Siemens Maxum II FID/FPD Flame Arrester Hastelloy-C 1460006-001
Description
Overview: A Critical Safety Component for Detector Venting
The Siemens Maxum II Flame Arrester Hastelloy-C, part number 1460006-001, is a safety-critical fitting used on the Flame Ionization Detector (FID) of the Siemens Maxum Edition II process gas chromatograph. Constructed from corrosion-resistant Hastelloy-C, this arrester threads into the FID bottom body, with its insert tube connecting to a union inside the analyzer oven, to prevent flame propagation out of the detector and back along the analyzer’s tubing – a mandatory protective measure on any combustion-based detector operating continuously in a hazardous-area process environment.
As an independent specialized supplier of Siemens Maxum Edition II analyzer spare parts, Seven Star LLC sources and supplies the flame arrester assembly 1460006-001 to refineries, gas plants, and petrochemical complexes across Oman and the wider GCC.Seven Star LLC supplies this item on request with the manufacturer documentation, and availability and lead time are confirmed at quotation. Note that the Flame Photometric Detector (FPD II) does not use this part: per the Siemens Maxum Edition II Detectors Service Manual, the FPD takes its exhaust from the combustion chamber through a flameproof joint rather than through a flame arrester, and FPD hardware carries separate Siemens part numbers.
Working Principle: Flame Propagation Prevention
A flame arrester works by forcing the gas stream through a network of narrow passages or a porous matrix with dimensions small enough that heat is dissipated faster than a flame front can propagate through them. On the FID, this principle isolates the hydrogen-fuelled detector flame from the tubing that runs back into the analyzer oven – if a flashback event were to occur inside the detector body, the arrester’s narrow internal geometry quenches the flame before it can travel out of the detector and into the surrounding analyzer enclosure.
The choice of Hastelloy-C construction reflects the corrosive and thermally demanding environment inside an operating FID detector body, where the arrester is exposed to combustion byproducts and sustained elevated temperature. Hastelloy-C’s resistance to oxidation and chemical attack ensures the arrester’s narrow flame-quenching geometry remains dimensionally stable and free of corrosion product buildup over long service intervals, preserving both its safety function and its gas flow characteristics.
Engineering Design of the Flame Arrester Assembly
The 1460006-001 flame arrester is machined to the precise internal tolerances required to provide a certified flame-quenching gas path while introducing minimal restriction to the detector’s normal gas flow. Its compact fitting is sized for direct installation into the FID bottom body, matching the Maxum Edition II’s standard detector plumbing without requiring custom adaptation.
Because this arrester sits directly in the flame path of a continuously operating combustion detector, its mechanical integrity is central to the ongoing safety certification of the analyzer installation. Genuine Siemens-specified Hastelloy-C arrester assemblies are manufactured and tested to maintain their flame-quenching performance across the detector’s full operating temperature range, which is a key reason process safety and instrumentation teams standardize on the correct OEM part number rather than substituting generic flame arrester fittings.
Key Features
The Flame Arrester Hastelloy-C 1460006-001 is engineered to protect Flame Ionization Detector installations on the Maxum Edition II. Key characteristics include:
- Direct-fit replacement flame arrester insert assembly for the FID detector module on the Maxum Edition II.
- Hastelloy-C construction for resistance to corrosion and combustion byproduct attack.
- Precision-machined internal geometry engineered to quench flame propagation with minimal flow restriction.
- Rated for the sustained elevated temperatures present inside an operating flame detector body.
- Genuine Siemens Maxum II part number 1460006-001 for correct safety-certified fit.
- Installs and removes with a 9/16 in open-end wrench, seating against its flat washer in the FID bottom body.
Installation and Replacement on the FID
The Siemens Maxum Edition II Detectors Service Manual identifies the flame arrester as three related items within the FID assembly: the Flame Arrestor Insert Assembly that threads into the narrow end of the FID bottom body, the flat washer that seats beneath it, and the Flame Arrestor Bushing and arrester that complete the assembly. Replacement is a mechanical operation carried out with the detector cooled and the hydrogen supply isolated. Tubing is first disconnected from the FID flame arrestor insert tube inside the oven, after which the insert is removed from the FID bottom body using a 9/16 in open-end wrench.
Reassembly is where most field errors occur. Siemens is explicit that the threads of the FID flame arrestor must be clean and free of lubricant or any other substance before the insert and its washer are placed into the FID bottom body and tightened, because a contaminated thread can compromise the flameproof path that the arrester exists to maintain. The insert tubing is then reconnected to the correct connection union in the oven. Because the Siemens Maxum II Flame Arrester Hastelloy-C is part of the analyzer’s flameproof containment rather than a consumable measuring component, instrumentation teams across Oman and the GCC generally schedule its inspection and replacement into planned detector overhauls and turnaround safety inspections rather than waiting for a symptom to appear.
Industrial Applications
The flame arrester assembly is a required maintenance item wherever a Maxum Edition II analyzer is fitted with an FID, including refinery hydrocarbon monitoring, natural gas quality analysis, and total hydrocarbon measurement on petrochemical process streams.
Seven Star LLC supports refinery instrumentation teams, gas processing operators, and petrochemical maintenance departments across Oman, Muscat, Sohar, and the broader GCC region with sourcing of this and other Maxum Edition II detector safety hardware, helping analyzer houses maintain both measurement continuity and process safety compliance.
Technical Specifications
The table below summarizes the core specifications of the Siemens Maxum II Flame Arrester Hastelloy-C as supplied by Seven Star LLC.
| Parameter | Specification |
|---|---|
| Model / Part Number | Flame Arrester Assembly, P/N 1460006-001 |
| Material | Hastelloy-C |
| Function | Flame propagation prevention (flashback protection) |
| Compatible Detector | Flame Ionization Detector (FID). Not used on the FPD II, which vents through a flameproof joint |
| Target Platform | Siemens Maxum Edition II Process Gas Chromatograph |
| Typical Location | Detector vent / inlet gas tubing |
| Hardware Condition | New, genuine Siemens part number |
| Assembly Items (per Siemens FID assembly) | Flame Arrestor Insert Assembly, flat washer, Flame Arrestor Bushing, Flame Arrestor |
| Mounting | Threads into the narrow end of the FID bottom body; insert tube connects to an oven union |
| Service Tool | 9/16 in open-end wrench |
| Installation Requirement | Threads must be clean and free of lubricant or other substances |
| Reference Document | Siemens Maxum Edition II Detectors Service Manual, A5E42019847001 |
Request a Quote for Siemens Maxum II FID/FPD Flame Arrester Hastelloy-C 1460006-001
Seven Star LLC is a dedicated supplier of Siemens Maxum Edition II process gas chromatograph spare parts and detector safety hardware throughout Oman and the GCC. To request a formal B2B quotation, verify current availability and lead time, or confirm compatibility of the Flame Arrester Hastelloy-C 1460006-001 with your FID detector configuration, contact our instrumentation sourcing team today.
Related Products
- Siemens Maxum II SYSCON Replacement Kit Compact Flash 2022018-001
- Dräger C-7540 Dissolved Oxygen Comparator (0–40 ppb)
- LAR 501-40-000215 Peristaltic Pump 5-Channel 24VAC 10RPM
- Siemens Maxum II Heater Cartridge A5E01673207
- Mitsubishi TN6RPC Gas Tube Dryer Set for NSX-2100 Sulfur Analyzer
- Yokogawa E7042UD Universal Zirconia Cell Assembly Kit for ZO21D/ZR22/ZR202
Datasheets & Documents
- Instruction Manual Siemens Maxum II FID/FPD Flame Arrester Hastelloy-C 1460006-001 Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.
Siemens company profile
| Founded | 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees |
|---|---|
| Founders | Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890) |
| First product | The pointer telegraph designed by Werner von Siemens |
| Headquarters | Munich, Germany (Siemens AG) |
| Ownership | Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies |
| Businesses acquired that appear in our range | Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003 |
| Product families | SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors |
Milestones
- 1847: Siemens & Halske starts work in Berlin with 10 employees.
- 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
- 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
- 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
- 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
- 2020: Siemens Energy is spun off and listed separately.
Choosing Siemens automation products
A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.
Where Siemens products are used
In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.
Siemens products we list
| Family | Examples |
|---|---|
| SIMATIC controllers and I/O | S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2 |
| HMI and networking | KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM |
| Drives, motors and power distribution | SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB |
| Process instruments | SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200 |
| Maxum II analyser spares | FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater |
| APACS and QUADLOG spares | QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable |
| Building technology | VPI46 PICV, VPF44, QFM1660 sensor |
Ordering Siemens products: what we need
Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.
Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.
Facts checked against Siemens's published history timeline, October 2026.
FAQ
Questions about the Siemens Maxum II FID/FPD Flame Arrester Hastelloy-C
Answers from our engineering team on installation, compatibility and integration.
01Which detectors use the 1460006-001 flame arrester?
The flame arrester assembly 1460006-001 is a common part used on both the Flame Ionization Detector (FID) and the Flame Photometric Detector (FPD II) on the Siemens Maxum Edition II process gas chromatograph.
02Why is Hastelloy-C used for this flame arrester?
Hastelloy-C resists oxidation and chemical attack from combustion byproducts and sustained elevated temperature inside an operating flame detector, keeping the arrester dimensionally stable and free of corrosion buildup over long service life.
03What safety function does this flame arrester perform?
The arrester forces gas through narrow internal passages that dissipate heat faster than a flame front can travel, quenching any flashback before it can propagate upstream into the analyzer's hydrogen and combustion air supply lines.
04Is this a routine maintenance item or only a failure replacement?
Because it is a safety-critical component, the flame arrester is typically replaced as part of scheduled detector overhaul and safety inspection intervals, not only when a fault is detected.
05Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens Maxum II Flame Arrester Hastelloy-C to refinery, gas processing, and petrochemical customers across Oman and the wider GCC region.


















Reviews
There are no reviews yet.