Brand

Systech

Systech is a British manufacturer of gas analysers, established in 1983 in Thame and now based in Buckinghamshire. It began with zirconia oxygen analysers and expanded into electrochemical and paramagnetic oxygen analysers and moisture analysers; its US sister company, Illinois Instruments, was founded in 1986. Systech, formerly Systech Illinois, is part of Industrial Physics. Seven Star LLC is an independent supplier in Muscat. We list Systech analyzers and spare parts for gas plants and laboratories in Oman and the GCC.

Read the full brand profile
  • 4 products
  • 2 categories

4 products

Brand profile

About Systech

All brands →
Founded
1983
Speciality
Gas analyzers for packaging and industry
Listed with us
4 products in 2 categories

Systech is a British manufacturer of gas analysers, established in 1983 in Thame and now based in Buckinghamshire. It began with zirconia oxygen analysers and expanded into electrochemical and paramagnetic oxygen analysers and moisture analysers; its US sister company, Illinois Instruments, was founded in 1986. Systech, formerly Systech Illinois, is part of Industrial Physics.

Seven Star LLC is an independent supplier in Muscat. We list Systech analyzers and spare parts for gas plants and laboratories in Oman and the GCC.

Systech company profile

Founded 1983, Thame, England
US arm Illinois Instruments, 1986
Group Industrial Physics
Ranges Trace ppb to high percentage oxygen
Product families ZR800 zirconia oxygen analysers, EC900 and EC91 electrochemical oxygen analysers, PM700 paramagnetic analysers, moisture analysers, sensors and spare boards

Milestones

  • 1983: Systech is established in Thame.
  • 1986: Illinois Instruments is founded in the US.

Systech product series

The ZR810 zirconia oxygen analyzer is listed for oxygen in nitrogen with ranges of 0-10 and 0-100 ppm and 0-10% O2, and in a version for argon and hydrogen.

Spare parts for the EC91 oxygen transmitter include the 091-024 main amplifier PCB and the 090182 trace stainless steel oxygen cell. Zirconia sensors give fast response and long life, but are not suitable where combustible gases would react at the hot sensor, so the sample gas composition must be checked.

Where Systech analyzers are used

Purity checks of nitrogen and argon, inert gas blanketing, gas production plants and laboratories.

Systech products we list

Family Examples
Gas Analyzer Accessories EC91 Main Amplifier PCB, Oxygen Sensor 090182
Gas Analyzer Systems ZR810 Zirconia Oxygen Analyzer, ZR810 Zirconia Oxygen Analyzer for Argon…

Ordering Systech products: what we need

Send the analyzer model and range, the sample gas, pressure and flow, or the part number of the spare being replaced.

Facts checked against Industrial Physics' Systech brand page and gasworld directory, October 2026.

Request a Quote for Systech Products

Looking for Systech parts not listed here, or pricing for a project? Send us the part numbers and quantities. Seven Star LLC sources genuine Systech products for customers across Oman and the GCC and replies with a formal quotation.

Free, no-obligation quotation · takes about 1 minute

Other enquiries: [email protected] · WhatsApp

FAQ

Questions about Systech

Common questions about Systech equipment, part numbers and supply to Oman and the GCC.

01What is the difference between Systech zirconia and electrochemical oxygen analyzers?
A zirconia cell, as in the ZR800 series, runs hot, responds quickly and covers a very large span from trace ppm to percent levels. It is not suited to gases that burn at the cell temperature. An electrochemical cell, as in the EC900 and the older EC91, works at ambient temperature and is a consumable that must be replaced periodically.
02How do I identify the right oxygen cell for an EC91 transmitter?
Use the part number on the cell itself or in the transmitter manual; the trace stainless-steel cell listed on our site is 090182. Cells differ by measuring range and by the gas they tolerate, so also send the transmitter model, its serial number and the gas being measured. We check the match in the manufacturer's documentation.
03Does the background gas matter when ordering a ZR810?
Yes. The analyzer is configured for its background gas, and flow components and calibration differ between, for example, nitrogen and argon. Reducing or flammable gases react on a hot zirconia cell and distort the reading, so always state the full gas composition. We confirm suitability with the manufacturer before quoting.
04What should I send for a quotation on Systech equipment?
For analyzers: gas, range, sample pressure and temperature, required outputs and alarms, and supply voltage. For spares: the part number, such as 091-024 for the EC91 main amplifier PCB, plus the instrument model and serial number. A nameplate photo is the quickest way to give us all of it.
05Is Seven Star LLC a distributor of Systech?
No. Seven Star LLC is an independent industrial supplier based in Muscat. We source Systech analyzers and spares through commercial channels, check the model or order code against the manufacturer's documentation before ordering, and provide the manufacturer's datasheet and the certificates the manufacturer issues with the order, on request.