Brand:

AMETEK 305121901S 3050 Calibrated QCM Moisture Sensor 0-100 ppm

Description

AMETEK 305121901S overview

AMETEK 305121901S is the calibrated quartz crystal microbalance (QCM) moisture sensor for the AMETEK 3050 series, in the 0-100 ppm version used in the SLR, DO and TE analyzers. The sensor is the consumable at the centre of a 3050 analyzer: it detects water vapour by the shift in frequency of a hygroscopic quartz crystal. The AMETEK listing notes a temporary long lead time, which is a reason buyers register demand early. The 3050 datasheet states a consumable service life exceeding three years and that no routine factory calibration is required.

The AMETEK 3050 series uses quartz crystal microbalance (QCM) technology with online verification for ppmv and sub-ppmv moisture in industrial gases. The datasheet describes a NIST-traceable dual-concentration moisture generator for scheduled or on-demand verification, a consumable service life exceeding three years, no routine factory calibration, and operation with up to 30 percent hydrogen sulfide or 100 percent carbon dioxide.

Key features of 305121901S

  • Calibrated QCM moisture sensor for 0-100 ppm service
  • For 3050 SLR, DO and TE analyzers
  • Field-replaceable unit with calibration supplied
  • Datasheet quotes service life exceeding 3 years
  • No routine factory calibration required for QCM sensor (datasheet)
  • Photo shows the sensor on its board with ribbon cable

305121901S technical specifications

Item Detail
Part number 305121901S
Description Sensor, calibrated, moisture QCM sensor for 3050, 0-100 ppm SLR/DO/TE
Technology Quartz crystal microbalance
Calibrated range (datasheet) SLR 0.1 to 100 ppmv; DO 0.02 to 100 ppmv; TE 0.01 to 100 ppmv
Accuracy (datasheet, TE) Plus or minus 0.01 ppmv or 10 percent of reading, whichever is greater
Dual moisture generator (datasheet) 0.5 ppmv and 1.0 ppmv on SLR, DO and TE
Technology (datasheet) Quartz crystal microbalance (QCM)
Ranges OLV 0.1-2500 ppmv; SLR 0.1-100 ppmv; DO 0.02-100 ppmv; TE 0.01-100 ppmv
Accuracy Plus or minus 0.1 ppmv or 10 percent (OLV), tighter on SLR, DO and TE
Online verification Internal NIST-traceable moisture source
Communications RS485 Modbus RTU, Ethernet, USB
Analog outputs Two isolated 16-bit 4-20 mA
Ambient Up to 50 degrees C, 60 degrees C with high temperature option
Certification IECEx/ATEX Zone 1

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 305121901S. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

The datasheet lists natural gas quality in pipelines and custody transfer stations, natural gas processing and dehydration, feedstock gas quality, molecular sieve dryer efficiency, cryo-recovery turbo expander inlet and outlet, and hydrogen recycle gas in continuous catalytic reactors. Oman and GCC gas processing plants and pipeline operators use moisture analyzers to protect against hydrate formation and to prove gas quality.

Where 305121901S is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 305121901S

Confirm the analyzer model (OLV, SLR, DO or TE), the calibrated range and the gas service (standard, CO2 or sour) before ordering the consumable, and quote the analyzer serial number where possible.

Part number 305121901S is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Replacement is a field-replaceable operation described in the 3050 user manual and in the AMETEK sensor removal video. Shut off sample flow and follow the analyzer procedure to remove the old sensor, handle the new sensor carefully and connect the ribbon cable as shown. After installation run the on-demand verification with the internal moisture generator at its two concentrations and allow the analyzer to dry down before comparing readings.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 305121901S. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

The 3050 can verify itself with its dual-concentration moisture generator, so a verification failure is the typical signal to replace the sensor. Follow the packaging and handling instructions that come with the sensor.

Related products and ordering notes

The H2S treated sensor 305122902S, the 2 micron filter 305448902S and the moisture generator refill kit are the other consumables in the 3050 family.

For a spare parts plan, list 305121901S against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Process plants in Oman and the wider GCC run long between shutdowns, which is why maintenance planners check part numbers early and hold critical spares. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We source against the exact number you give us and confirm availability and lead time before you commit.

Frequently asked questions about 305121901S

  • What is AMETEK 305121901S? It is the calibrated QCM moisture sensor, 0-100 ppm, for the AMETEK 3050 SLR, DO and TE analyzers.
  • How long does the 3050 sensor last? The datasheet states a consumable service life exceeding three years.
  • What does the QCM technology measure? It measures moisture in industrial gases by monitoring the frequency change of a quartz crystal, as described in the 3050 datasheet.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 305121901S, send the RFQ with the part number 305121901S, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK 3050 Series Moisture Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 305121901S 3050 Calibrated QCM Moisture

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 305121901S?
It is the calibrated QCM moisture sensor, 0-100 ppm, for the AMETEK 3050 SLR, DO and TE analyzers.
02How long does the 3050 sensor last?
The datasheet states a consumable service life exceeding three years.
03What does the QCM technology measure?
It measures moisture in industrial gases by monitoring the frequency change of a quartz crystal, as described in the 3050 datasheet.
04Is there a lead time warning?
The AMETEK listing notes a temporary long lead time, so confirm availability early.
05How do I request a quotation for 305121901S?
Send the part number 305121901S, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.