Brand:

Siemens Maxum II Heater Cartridge A5E01673207

Description

Overview: Precise Thermal Control for Combustion Detectors

The Siemens Maxum II Heater Cartridge, part number A5E01673207, is a 1-inch, 120V, 80W cartridge heater fitted with 450°C-rated lead wire, used to maintain the elevated, tightly controlled operating temperature required inside the Flame Ionization Detector (FID) and Flame Photometric Detector (FPD) modules of the Siemens Maxum Edition II process gas chromatograph. Stable detector body temperature is essential to repeatable flame ionization and flame photometric measurement, making this heater cartridge a core thermal-management component rather than a simple accessory.

As an independent specialized supplier of Siemens Maxum Edition II analyzer spare parts, Seven Star LLC sources and supplies the heater cartridge A5E01673207 to refineries, gas plants, and petrochemical complexes across Oman and the wider GCC.Seven Star LLC supplies this item on request with the manufacturer documentation, and availability and lead time are confirmed at quotation.

Working Principle: Resistive Cartridge Heating

The A5E01673207 cartridge heater operates on straightforward resistive heating principles: a coiled resistance element inside a compact 1-inch cylindrical sheath converts electrical energy from the 120V supply directly into heat, which conducts outward through the sheath wall into the surrounding detector body metal. Because the heating element is fully enclosed within a sealed metal sheath, the cartridge can be inserted directly into a bored mounting hole in the FID or FPD detector block, providing efficient, localized heat transfer exactly where the detector’s flame chamber and sensing electronics require it.

The cartridge’s 450°C-rated lead wire allows it to operate safely in the immediate vicinity of the detector’s hot zone without insulation breakdown, while its 80W power rating is matched to the thermal mass and heat-loss characteristics of the FID/FPD detector body to achieve and hold the correct operating temperature under closed-loop RTD-based temperature control from the Detector Personality Module (DPM) and PECM. Stable, accurate heater performance directly supports flame stability and measurement repeatability in both flame-based detector types.

Engineering Design of the Heater Cartridge

The heater cartridge is built as a compact, sealed 1-inch cylindrical unit sized for direct insertion into the standard FID/FPD detector body mounting bore, requiring no modification to the detector housing for like-for-like replacement. Its 450°C-rated lead wire is selected specifically to withstand the elevated ambient temperatures present near an operating flame detector, where standard insulation would degrade prematurely.

Because detector temperature stability is directly tied to measurement accuracy, the cartridge is manufactured to consistent resistance and power tolerances so that replacement units behave predictably under the analyzer’s existing RTD feedback and heater-control loop, without requiring recalibration of the temperature control parameters.

Key Features

The Heater Cartridge A5E01673207 delivers the precise, reliable thermal performance that flame-based detectors depend on. Key characteristics include:

  • Compact 1-inch cartridge form factor for direct insertion into the FID/FPD detector body.
  • 120V, 80W resistive heating element matched to detector thermal mass requirements.
  • 450°C-rated lead wire suited to the elevated ambient temperatures near an operating flame detector.
  • Compatible with both FID and FPD detector modules on the Maxum Edition II.
  • Genuine Siemens Maxum II part number for correct fit and predictable performance under existing RTD control loops.

Industrial Applications

The heater cartridge is a routine wear-and-maintenance item on any Maxum Edition II analyzer fitted with an FID or FPD detector, including refinery hydrocarbon monitoring, natural gas quality analysis, and sulfur-sensitive petrochemical process streams. It is typically replaced when heater failure alarms appear on the analyzer’s diagnostics, or proactively during scheduled detector maintenance to avoid unplanned measurement interruption.

Seven Star LLC supports refinery instrumentation teams, gas processing operators, and petrochemical maintenance departments across Oman, Muscat, Sohar, and the broader GCC region with sourcing of Maxum Edition II detector heater hardware, helping analyzer houses maintain continuous, stable flame detector operation.

Technical Specifications

The table below summarizes the core specifications of the Siemens Maxum II Heater Cartridge as supplied by Seven Star LLC.

Parameter Specification
Model / Part Number Heater Cartridge, P/N A5E01673207
Compatible Detectors FID and FPD
Size 1 inch
Voltage 120V
Power 80W
Lead Wire Rating 450°C
Target Platform Siemens Maxum Edition II Process Gas Chromatograph
Hardware Condition New, genuine Siemens part number

Why Choose Seven Star LLC for Maxum II Detector Heater Sourcing

A generic 120V cartridge heater that fits the mounting bore is not automatically a safe substitute for the genuine A5E01673207 – wattage and resistance tolerance both need to match the PECM’s existing RTD feedback loop, or the detector’s temperature control can overshoot or hunt in ways that quietly degrade FID/FPD baseline stability long before an outright heater failure alarm appears. Seven Star LLC verifies the exact part number and electrical rating against the customer’s specific detector configuration before shipping, rather than assuming a visually similar aftermarket cartridge will behave identically under closed-loop control. We also help refinery and gas plant instrumentation teams plan spare heater stock proactively, since scheduling a replacement during planned detector maintenance avoids the unplanned flame-detector downtime a mid-run heater failure would otherwise cause, and we coordinate delivery across Muscat, Sohar, and the broader GCC around scheduled analyzer service windows.

Request a Quote for Siemens Maxum II Heater Cartridge A5E01673207

Seven Star LLC is a dedicated supplier of Siemens Maxum Edition II process gas chromatograph spare parts and detector thermal hardware throughout Oman and the GCC. To request a formal B2B quotation, verify current availability and lead time, or confirm compatibility of the Heater Cartridge A5E01673207 with your specific FID or FPD configuration, contact our instrumentation sourcing team today.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Siemens Maxum II Heater Cartridge A5E01673207 Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.

Siemens company profile

Founded 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees
Founders Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890)
First product The pointer telegraph designed by Werner von Siemens
Headquarters Munich, Germany (Siemens AG)
Ownership Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies
Businesses acquired that appear in our range Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003
Product families SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors

Milestones

  • 1847: Siemens & Halske starts work in Berlin with 10 employees.
  • 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
  • 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
  • 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
  • 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
  • 2020: Siemens Energy is spun off and listed separately.

Choosing Siemens automation products

A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.

Where Siemens products are used

In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.

Siemens products we list

Family Examples
SIMATIC controllers and I/O S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2
HMI and networking KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM
Drives, motors and power distribution SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB
Process instruments SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200
Maxum II analyser spares FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater
APACS and QUADLOG spares QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable
Building technology VPI46 PICV, VPF44, QFM1660 sensor

Ordering Siemens products: what we need

Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.

Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.

Facts checked against Siemens's published history timeline, October 2026.

FAQ

Questions about the Siemens Maxum II Heater Cartridge A5E01673207

Answers from our engineering team on installation, compatibility and integration.

01Which detectors use the A5E01673207 heater cartridge?
This heater cartridge is used in both the Flame Ionization Detector (FID) and Flame Photometric Detector (FPD) modules on the Siemens Maxum Edition II process gas chromatograph.
02What are the electrical specifications of this heater cartridge?
The heater cartridge is rated for 120V and 80W, with lead wire rated to withstand temperatures up to 450 degrees C near the detector's hot zone.
03Why is heater cartridge condition important for measurement accuracy?
Stable detector body temperature directly affects flame stability and measurement repeatability in flame-based detectors, so a degraded or failed heater cartridge can compromise analytical accuracy before it fully fails.
04Does replacing the heater cartridge require recalibrating temperature control?
No, genuine replacement cartridges are manufactured to consistent resistance and power tolerances so they behave predictably under the analyzer's existing RTD feedback and heater-control loop.
05Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens Maxum II Heater Cartridge A5E01673207 to refinery, gas processing, and petrochemical customers across Oman and the wider GCC region.