Teledyne AP00465 Model PX2 LED UV Fluorescence Transmitter with PMT Detector
Description
Overview
The Teledyne AP00465 is the Model PX2 LED UV Fluorescence Transmitter, a photometric detection module built around a photomultiplier tube (PMT) sensor that forms the analytical core of Teledyne API’s UV fluorescence sulfur dioxide and trace-gas analyzer platforms. The PX2 transmitter converts ultraviolet fluorescence emitted by excited SO2 molecules into a precise electrical signal, using a stabilized LED excitation source in place of older, less stable UV lamp designs, resulting in longer service intervals and more consistent baseline performance over the analyzer’s operating life.
With engineering support in Muscat, Seven Star LLC supplies the Teledyne AP00465 PX2 transmitter to continuous emissions monitoring system (CEMS) integrators, environmental compliance laboratories, and ambient air quality network operators throughout Muscat, Sohar, and Salalah. Every unit is sourced through Teledyne’s traceable spares and OEM channel, ensuring full compatibility with existing Teledyne API SO2 and trace-level gas analyzer housings.
Operating Principle
The PX2 transmitter operates on the principle of UV fluorescence: sample gas is exposed to ultraviolet light at a wavelength that excites SO2 molecules to a higher energy state, and as the molecules relax back to their ground state they emit fluorescent light at a longer wavelength, proportional in intensity to the SO2 concentration in the sample. The photomultiplier tube detector inside the Teledyne AP00465 housing captures this weak fluorescent signal and amplifies it by many orders of magnitude, allowing the analyzer to resolve SO2 concentrations down to parts-per-billion levels.
Because the PX2 uses a solid-state LED excitation source rather than a mercury vapor UV lamp, the transmitter reaches optical stability far faster after power-up and exhibits significantly less long-term intensity drift, which translates directly into fewer baseline recalibrations and more reliable unattended operation at remote or difficult-to-access monitoring sites. No moving parts sit in the optical path, eliminating a common source of mechanical wear and contamination found in older photometric designs, and the sealed PMT and LED assembly resists the ingress of dust and moisture common in outdoor CEMS shelters.
Engineering Design of the Teledyne AP00465
The Teledyne AP00465 is housed in a rugged, black anodized aluminum enclosure that shields the sensitive PMT and LED optics from stray light and electromagnetic interference, with a labeled USB interface connector provided for direct digital communication with the host analyzer’s data acquisition electronics. The compact, self-contained module bolts directly into the analyzer’s optical bench assembly using factory-aligned mounting features, preserving the precise optical geometry required for accurate fluorescence detection.
Field replacement follows Teledyne’s documented module-exchange procedure: the analyzer is powered down, the optical bench cover is removed, and the PX2 transmitter is unbolted and replaced as a complete sealed unit, avoiding the need to open or realign individual optical components in the field. After installation, a standard span and zero verification with certified SO2 calibration gas confirms that the replacement transmitter is performing to the analyzer’s original factory specification.
Key Features
The Teledyne AP00465 PX2 transmitter is engineered to deliver dependable, low-maintenance photometric performance for demanding compliance and research applications:
- Photomultiplier tube detection provides parts-per-billion sensitivity for trace SO2 and related sulfur compound measurement.
- Stabilized LED excitation source replaces traditional UV lamps, extending service life and reducing drift-related recalibration.
- Sealed, self-contained optical module simplifies field replacement without disturbing analyzer optical alignment.
- USB digital interface enables direct, high-speed communication with the host analyzer’s processing electronics.
- Rugged anodized aluminum housing resists electromagnetic interference and physical damage in industrial shelter environments.
- No moving parts in the optical signal path, reducing mechanical wear and long-term maintenance burden.
- Compatible with Teledyne API’s established fleet of UV fluorescence SO2 and trace-gas continuous emissions monitors.
- Supported by Seven Star LLC’s applications engineering for CEMS uptime restoration.
Industrial Applications
The Teledyne AP00465 PX2 transmitter is deployed wherever accurate, continuous SO2 and trace sulfur gas measurement is required for regulatory compliance or process safety. Typical installations include refinery and gas plant continuous emissions monitoring systems tracking stack SO2 output, ambient air quality monitoring networks positioned near industrial zones and urban centers, and environmental research stations characterizing regional air quality trends across the Gulf.
Backed by manufacturer datasheet documentation, Seven Star LLC distributes this transmitter module to environmental consultancies, CEMS system integrators, and government monitoring authorities supporting compliance programs across the Sultanate of Oman, Muscat, and the Sohar and Salalah economic zones. Contact Seven Star LLC for a quotation and current lead time for the Teledyne AP00465 Model PX2 LED UV Fluorescence Transmitter with PMT Detector.
Technical Specifications
The table below summarizes the key specifications relevant to the Teledyne AP00465 Model PX2 transmitter.
| Parameter | Specification |
|---|---|
| Model | Teledyne AP00465 (Model PX2) |
| Description | LED UV Fluorescence Transmitter with PMT Detector |
| Detection Method | UV fluorescence, photomultiplier tube detector |
| Excitation Source | Stabilized LED (solid-state) |
| Target Measurement | Sulfur dioxide (SO2) and related trace gases |
| Interface | USB digital communication |
| Housing | Anodized aluminum, sealed optical module |
| Compatible Platform | Teledyne API UV fluorescence SO2/trace-gas analyzers |
| Recommended Calibration | Span/zero verification with certified SO2 gas after replacement |
Request a Quote for Teledyne AP00465 Model PX2 LED UV Fluorescence Transmitter with PMT Detector
Seven Star LLC invites CEMS integrators, environmental compliance managers, and laboratory procurement teams across Oman and the GCC to submit a formal RFQ for the Teledyne AP00465 PX2 LED UV fluorescence transmitter. Working closely with plant engineers in the region, we supply critical analyzer modules on request, provide full technical datasheets on request, and connect customers directly with our instrumentation division for CEMS application support. Contact Seven Star LLC today to confirm availability, lead time, and pricing for your emissions monitoring program.
Related Products
- PR Electronics 5335D 2-Wire HART Transmitter for RTD and TC
- Simtronics GD10-P00-17DG-0XH-00 Infrared Gas Detector (GD10P Series)
- Hach LBOD0101Intellical Laboratory Luminescent Optical Dissolved oxygen
- Siemens Maxum II FID 302A Detector Assembly 2021651-002
- LAR 501-08-000045 Gas Drying Tube for Carrier TOCUV1A0 – Long
- AMETEK 7000-330-SE LCD Host Interface PCB Assembly
- Teledyne D70046A PCB Assembly Interface, MDL 3020M
Reviews (0)
How would you rate this product? Cancel reply
About brand
Two different product lines sit behind the Teledyne name on this page: process gas analyzers and sensors from Teledyne Analytical Instruments, and fixed gas and flame detectors from Teledyne Gas and Flame Detection, the home of the Detcon name. Seven Star LLC lists Teledyne oxygen and moisture analyzers, analyzer circuit boards, replacement sensors and Detcon detectors, and sources them by part number for plants and utilities in Oman.
Teledyne analyzers, sensors and Detcon detectors listed
The listing is weighted toward spare parts for installed analyzers:
- 3000 series oxygen analyzers, such as the 3000RS, with PCB assemblies for Model 3000 and 3020M units and the P01962 power supply, which replaces the obsolete B70284
- 8800B trace moisture analyzer from the 8800 series
- B71875 InstaTrace oxygen sensor
- Liquid analysis parts: the CP03030 pH sensor cartridge and the S02312 free chlorine sensor
- Fire and gas: the Spyglass SG50-F-IR3 triple IR flame detector, listed here under Teledyne Detcon, and the iTrans 2 fixed gas monitor
Where Teledyne analyzers and Detcon gas detectors are used
Teledyne oxygen analyzers measure trace and percent oxygen in nitrogen, hydrocarbon and inert gas streams, for example on air separation units, blanketing systems and gas pipelines. Trace moisture analyzers serve instrument air and dry gas service. Teledyne Detcon gas detectors and flame detectors are used on wellsites, compressor stations, tank farms and water treatment plants in the GCC, wired to a controller or the plant safety system.
Ordering Teledyne parts: what we need
Teledyne Analytical Instruments parts are identified by a letter and number code, such as C70043A or B71875, and by the analyzer model and serial number. Send all of them. Oxygen sensors are selected by class for the background gas and range, so name the sample gas composition and the analyzer model. For a Teledyne Detcon gas detector or flame detector, send the model and full part number from the label, the target gas and range, output, and the area approval required. We check each code against the manufacturer's documentation and propose the listed replacement when a part has been superseded.
Browse Teledyne (Detcon) products by category: Gas Analyzer Accessories, Fire & Gas Detector, Liquid Analysis Sensors, Gas Analyzer Systems.
Related products
Frequently Asked Questions
The AP00465 is a UV fluorescence photometric transmitter with a photomultiplier tube detector, designed primarily for trace-level sulfur dioxide (SO2) measurement in continuous emissions and ambient air monitoring analyzers.
The PX2 is a sealed, self-contained optical module that bolts into the analyzer optical bench using factory-aligned mounting features, so replacement is quick and does not require field realignment of individual optical components.
The AP00465 PX2 transmitter is designed for Teledyne API UV fluorescence SO2 and trace-gas analyzer platforms; customers should confirm exact model compatibility with Seven Star LLC technical support before ordering.
The stabilized LED source reaches optical stability faster after power-up and exhibits significantly less long-term intensity drift than mercury vapor UV lamps, reducing recalibration frequency and improving unattended monitoring reliability.
Yes, Seven Star LLC is an experienced supplier of Teledyne (Detcon) analytical and gas detection products across the Sultanate of Oman and the GCC.