Brand: Rosemount
Rosemount 02120-7000-0005 2120 8/16 mA Cassette
Description
Rosemount 02120-7000-0005 at a glance
Rosemount 02120-7000-0005 is the dark-blue 8/16 mA output cassette for the Rosemount 2120 vibrating fork level switch, known in the ordering table as electronic type H. Instead of switching a load or closing a contact, the cassette reports the wet or dry state as one of two current levels, 8 mA or 16 mA, which an intrinsically safe isolating amplifier converts into a relay or digital input for the control system. It is supplied as a replacement module for 2120 switches shipped since June 2013.
The current-level signal has a practical benefit that a plain contact does not: the two defined levels stay distinguishable from a broken wire or a lost supply, so a control system can raise a wiring-fault alarm in addition to the level alarm.
Specification table for the module
| Parameter | Value |
|---|---|
| Part number | 02120-7000-0005 |
| Datasheet description | Replacement Cassette: 8/16 mA output |
| Label colour | Dark blue |
| Ordering code | Electronic type H |
| Output | 8 mA or 16 mA current levels |
| Interface | Certified intrinsically safe isolating amplifier to IEC 60947-5-6 |
| Certification availability | All product certification codes, including the Korean IP code |
| Dust-area ambient limit | 158 deg F (70 deg C) for this cassette |
| Surge protection | Yes, IEC 61326 |
| Safety options QS, QT | Available |
| Switching delay | 0.3, 1, 3, 10, 30 s |
| Operating altitude | up to 6562 ft (2000 m) |
| Switching hysteresis in water | 0.1 in (2.5 mm) |
Choosing 02120-7000-0005 instead of another 2120 module
Among the 2120 electronics, 02120-7000-0005 has the widest certification reach. NAMUR (code K) is excluded from the Korean IP approval and China I3 is offered only on NAMUR, but the 8/16 mA type is listed for every code in the table. If a plant standard is a two-level loop that distinguishes line break, this is the module; if the control system has a native NAMUR input, 02120-7000-0003 is the matching part. For three-wire PLC wiring pick 02120-7000-0002, for relay outputs 02120-7000-0004 or 02120-7000-0007, and for mains load switching 02120-7000-0001.
The dust note is specific to this cassette: on dust-hazard certifications the ambient temperature is restricted to 158 deg F (70 deg C), whereas the rest of the 2120 envelope extends to 176 deg F (80 deg C) according to the temperature figure. Engineers placing switches under a hot Gulf sun in a dusty grain or cement installation should review that limit.
A further point on the signal itself: because the output is a current rather than a voltage or a contact, the cable run between the tank and the marshalling cabinet can be long without voltage-drop concerns, and the same twisted pair can be reused when an old float switch loop is converted. The isolating amplifier does the work of translating 8 mA and 16 mA into a clean contact, which also keeps the field wiring electrically separate from the safe-area control system.
Applications where an 8/16 mA signature fits
- High-level alarms on crude and product tanks wired to a safety instrumented system through IS barriers.
- Low-level cut-out of lube-oil and seal-oil reservoirs, where a broken wire must be seen as a fault.
- Sump and drain-pit high alarms in power and water plants.
- Chemical dosing tanks in desalination sites, wired to isolating amplifiers in the marshalling cabinet.
- Remote pits connected through a Rosemount 702 wireless discrete transmitter, a combination mentioned in the datasheet for wireless applications.
The fork itself needs no calibration and is virtually unaffected by foam, bubbles, vibration or coating, which is why the electronics, not the fork, are the part kept as a spare. Wiring access is simple as well: a plug-in cassette sits beneath the housing cover, and the same 2120 can accept any of six cassette types, so one fork design serves PLC, relay, NAMUR and current-signature systems alike.
Wiring and replacement procedure for 02120-7000-0005
The datasheet wiring figure for the 8/16 mA cassette shows two terminals, minus and plus, connected to the isolating amplifier. Isolate the loop, open the cover, remove the old cassette and seat 02120-7000-0005; terminal capacity is 26 to 14 AWG. Because intrinsically safe cassettes may only be replaced by the same IS type, confirm that the removed module is also dark blue before fitting. Move the original part-number marking onto the new label as the manufacturer instructs, so that the nameplate and the module remain traceable. Power up, watch the heartbeat LED, wet the fork and confirm the amplifier reads the other current level. Hold a magnet at the side test point to prove the whole loop.
Behaviour in the process
Switching delay is selectable between 0.3 and 30 seconds for each direction, which stops a splashing tank from toggling the loop. A fork length of 1.7 in (44 mm) is standard on threaded builds and 4.0 in (102 mm) on flanged builds, with customer-specified extensions up to 157.5 in (4000 mm). Liquids must be at least 600 kg/m3 in density and no more viscous than 10000 cP, and solids should be smaller than 0.2 in (5 mm) to avoid bridging between the tines.
Inspection, proof testing and spares
For safety loops the 2120 can be ordered with a prior-use FMEDA certificate or IEC 61508 safety certification (options QS and QT), and these options are available with the 8/16 mA electronics. Plants that run proof tests should schedule the magnetic test at each turnaround and log the result. Keep at least one dark-blue module in stock per plant area that uses IS 8/16 mA loops, labelled with the loop numbers it covers.
Documents and quotation
The 2120 datasheet that lists 02120-7000-0005 among its replacement cassettes is attached to this page. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send your RFQ with the part number 02120-7000-0005, the quantity and the 2120 nameplate model code, plus the delivery address in Oman or the GCC, for a prompt response.
Other Models in the Rosemount 2120 Spares Range
Seven Star LLC supplies models from the Rosemount 2120 Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc Cassette | Level Switches | View details |
| Rosemount 02120-7000-0001 2120 Direct Load Cassette | Level Switches | View details |
| Rosemount 02120-7000-0005 2120 8/16 mA Cassette | Level Switches | You are viewing this model |
| Rosemount 02100-1060-0001 2120 Quick Release Kit | Level Switches | View details |
| Rosemount 02120-7000-0003 2120 NAMUR Cassette | Level Switches | View details |
| Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP Tri Clamp | Level Switches | View details |
Datasheets & Documents
- Datasheet Rosemount 02120-7000-0005 2120 8/16 mA Cassette Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments
Milestones
1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.
Rosemount products we list
FamilyModelsTypical use
Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 02120-7000-0005 2120 8/16 mA Cassette
Answers from our engineering team on installation, compatibility and integration.
01What does Rosemount 02120-7000-0005 do?
It is the dark-blue 8/16 mA output replacement cassette (electronic type H) for the Rosemount 2120 vibrating fork level switch.
02What must it be connected to?
The datasheet shows it connected to a certified intrinsically safe isolating amplifier to IEC 60947-5-6, not directly to a load.
03Is 02120-7000-0005 available with all approvals?
Yes. In the 2120 ordering table electronic type H is available with all product certification codes, including the Korean IP intrinsic safety code.
04Is there an ambient limit specific to this cassette?
Yes. For dust applications the ambient temperature for the 8/16 mA cassette is limited to 158 deg F (70 deg C).
05Which 2120 units accept this cassette?
The datasheet states the replacement cassettes are for 2120 versions shipped since June 2013; IS modules may be replaced only by the same type.


















Reviews
There are no reviews yet.