Brand:

Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc Cassette

Description

Why plants ask for 02120-7000-0007

Not every tank has mains power. Rosemount 02120-7000-0007 is the relay version of the Rosemount 2120 electronics designed for a low-voltage supply, 9 to 30 Vdc with 12 Vdc nominal, in the datasheet’s electronic type E. It gives the user two sets of changeover contacts (a double-pole changeover, DPCO), so one fork can switch an alarm and a pump interlock at the same time. For solar-powered or battery-backed remote sites around Oman, where a 12 or 24 volt bus is the only supply, this is the cassette that makes a 2120 usable.

It carries a green label, the same colour as the standard-voltage relay cassette 02120-7000-0004, so check the part number on the module and not just its colour.

Electrical data in one place

Parameter Value
Part number 02120-7000-0007
Description Replacement cassette: Relay DPCO, 9 to 30 Vdc (12 Vdc nominal) version
Label colour Green
Ordering code Electronic type E
Contacts Two changeover sets, terminals NC, C, NO for each (terminals 4 to 9)
Supply terminals Two, 0 V and +V; supply fuse 0.5 A time-lag
Certification limited to E5, E6 and G-series codes
Polarity insensitive No, the 12 Vdc version is excluded from that protection
Surge protection Yes, IEC 61326
Safety options QS/QT Not available with type E
Switching delay 0.3 to 30 s selectable
Terminal wire size 26 to 14 AWG

How 02120-7000-0007 differs from the standard relay cassette

The two relay modules look alike but differ in the supply they accept and the approvals attached to them. 02120-7000-0004 runs from 20 to 264 Vac or 20 to 60 Vdc, can be combined with NA, E-series and G-series approvals, and is polarity insensitive. 02120-7000-0007 is limited to 9 to 30 Vdc, can be used only with the USA and Canada explosion-proof codes E5 and E6 and the ordinary-location G codes, and must be wired with the correct polarity. Neither relay module can be paired with the IS I-codes, which belong to the NAMUR and 8/16 mA cassettes.

Applications for a low-voltage DPCO relay

Think of remote metering stations, wellhead skids and booster pumps with 24 V control cabinets. One changeover set can drive the local pump starter coil while the second sends a volt-free alarm to the RTU. In explosion-proof builds the module sits in an aluminium or stainless housing with 3/4-in NPT entries and USA or Canada approvals; for the ATEX/IECEx world, another electronics type is needed.

Housings that suit this module are the aluminium alloy Y style with 3/4-in. NPT entries and the stainless steel T style with the same entries, which the datasheet lists for the USA and Canadian explosion-proof codes, or the glass-filled nylon A and D housings for ordinary-location duty. A heartbeat LED is visible through the lens of the plastic housings, so a technician walking the plant can see at once whether the low-voltage cassette is alive. Keep in mind that a 12 volt nominal relay version often sits behind a solar controller or UPS bus, so verify the voltage with the unit under load rather than from the open-circuit figure; a battery that sags below 9 volts will drop the relays out and look like a dry fork. Also remember that a fork length can be customised from 3.8 in (95 mm) minimum on 3/4-in. threaded builds to 157.5 in (4000 mm) maximum, so one cassette serves very different vessel depths.

Install, test and prove

Check the supply is within 9 to 30 Vdc and polarity is correct, remove the old module, seat 02120-7000-0007, and connect the 0 V and +V supply plus the contact terminals. Confirm the 0.5 A time-lag fuse in the supply. Set the switching mode and delay on the cassette; the delay (0.3, 1, 3, 10 or 30 s) is applied both dry-to-wet and wet-to-dry. With the heartbeat LED flashing for the off state and steady for the on state, check each relay pair with a meter, then apply the magnet to the side test point and watch both outputs change.

Selection guidance and caveats

  • Do not choose type E if functional-safety certification (QS or QT) is required; the datasheet excludes it for types T and E.
  • Only E5, E6, G5 and G6 style approvals are available, so check the site’s area classification before ordering.
  • If the supply may exceed 30 Vdc during charging, use the 20 to 264 Vac or 20 to 60 Vdc relay instead.
  • Contact ratings should be taken from the specification of the cassette label; keep inductive loads suppressed.

Maintenance notes

The fork is maintenance free apart from cleaning, so keep a spare module for each supply voltage used. Wetted parts are 316/316L stainless steel (dual certified 1.4401/1.4404), Alloy C-276 or ECTFE-coated steel for flanged units, and none of that changes when the electronics are replaced. The switching point is 0.5 in (13 mm) from the fork tip when mounted vertically in water, with 0.1 in (2.5 mm) hysteresis, and the fast-drip fork shape returns the output to the dry state quickly in viscous liquids up to 10000 cP. The unit can be mounted horizontally or vertically at any angle through a tank wall or a pipe. Maximum fork pressure is shown on the 2120 datasheet as a curve, with Tri Clamp builds limited to 435 psig (30 barg). Store spare cassettes dry and in their antistatic packing, and label the shelf with the loop numbers.

Because this electronics type carries restricted approvals, keep the nameplate and the cassette label together in the instrument file. If a site later moves to ATEX or IECEx-certified equipment the cassette cannot simply be left in place, and a different electronics type together with the matching housing would be specified. The datasheet notes that the certificate set for the product is published separately as the Rosemount 2120 Product Certifications document, which is the reference to open before any change of area classification.

Documents and quotation

The relevant 2120 datasheet, including the replacement cassette table with 02120-7000-0007, is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send an RFQ with part number 02120-7000-0007, quantity and the nameplate model code of the 2120 to be repaired, with the delivery destination in Oman or the GCC.

Other Models in the Rosemount 2120 Spares Range

Seven Star LLC supplies models from the Rosemount 2120 Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc CassetteLevel SwitchesYou are viewing this model
Rosemount 02120-7000-0001 2120 Direct Load CassetteLevel SwitchesView details
Rosemount 02120-7000-0005 2120 8/16 mA CassetteLevel SwitchesView details
Rosemount 02100-1060-0001 2120 Quick Release KitLevel SwitchesView details
Rosemount 02120-7000-0003 2120 NAMUR CassetteLevel SwitchesView details
Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP Tri ClampLevel SwitchesView details
Datasheets & Documents
  • PDF Datasheet Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc Cassette Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc

Answers from our engineering team on installation, compatibility and integration.

01What supply does Rosemount 02120-7000-0007 use?
It is the relay DPCO cassette for a 9 to 30 Vdc supply, with 12 Vdc nominal, and a 0.5 A time-lag fuse shown in the wiring figure.
02How is it different from 02120-7000-0004?
The 0004 module is the standard relay for 20 to 264 Vac or 20 to 60 Vdc; the 0007 module is the low-voltage version with E5, E6 and G approvals only.
03Is the 0007 cassette polarity insensitive?
No. The datasheet lists polarity insensitivity for relay electronics except the 12 Vdc version, so observe the polarity of the 0 V and +V terminals.
04Can 02120-7000-0007 be ordered with safety certification?
No. The QS and QT safety options are stated as not available with electronic type codes T or E.
05How many contacts does the relay have?
It has a double-pole changeover arrangement: two sets of normally closed, common and normally open terminals.