Rosemount 02100-1060-0001 quick release kit explained
Rosemount 02100-1060-0001 is the quick release kit for the Rosemount 2120 vibrating fork level switch. The datasheet describes it as a set containing a 2-in. Tri Clamp, a seal and a quick release device for a 2-in. NPT process connection. It turns a threaded vessel nozzle into a clamp-style joint, so the 2120 can be lifted out for inspection, proof testing or servicing without unscrewing a whole instrument from a female thread.
The kit is an accessory, not a transmitter, but for plants that proof-test overfill switches on a fixed schedule it pays for itself in labour saved at each shutdown.
Contents and conditions of use
| Parameter | Value |
|---|---|
| Part number | 02100-1060-0001 |
| Kit contents | 2-in. Tri Clamp, seal, quick release device |
| Vessel connection | Existing 2-in. NPT process connection |
| Fits | 2120 ordered with the 2-in. (51 mm) Tri Clamp option |
| Hygienic status | Not approved for use with 3-A or EHEDG approved products |
| FDA / ASME-BPE | Not assessed for FDA or ASME-BPE compliant products |
| Related literature | Release Kit Quick Start Guide (listed in the datasheet) |
| Max pressure of Tri Clamp 2120 builds | 435 psig (30 barg) |
| Process temperature of the 2120 | minus 40 to 302 deg F (minus 40 to 150 deg C) |
Where 02100-1060-0001 differs from other 2120 accessories
The 2120 spares list includes seals, an adaptor boss, a Tri Clamp kit, a test magnet and plug-in cassettes. Among them, 02100-1060-0001 is the only part that includes a quick release device. The plain 2-in. Tri Clamp kit 02100-1020-0001 gives a vessel fitting, clamp ring and seal, while the adaptor boss 02100-1010-0001 converts a 1-in. BSPP thread to a 1 1/2-in. Tri Clamp. The quick release kit is therefore the right choice only when the vessel already carries a 2-in. NPT socket and the 2120 itself has the 2-in. Tri Clamp connection.
Typical uses in Gulf process plants
Overfill-prevention switches are SIL-rated safeguards that must be proof-tested, and the 2120 is third-party assessed to IEC 61508. Pulling the fork for a wet test is easier when a clamp, not a thread, holds it. Typical examples are bulk chemical tanks at ports, water treatment dosing vessels and food-grade tanks that are CIP-cleaned. Remember the kit is excluded from hygienic claims, so sanitary tanks that need 3-A or EHEDG compliance should use the polished Tri Clamp 2120 builds with their own hygienic fittings.
The practical gain is time. A threaded 2-in. NPT joint on a long-serving tank can seize, and removing the fork may need a large wrench at height. With the clamp ring, one person can release the joint, lift the 2120 out, check the tines for build-up, test them in a bucket of water and reinstall. For safety instrumented functions, proof-test intervals are set by the safety manual and plant policy, and a quick and repeatable test method is more likely to be done on schedule. The telescopic test magnet and the heartbeat LED supplement this: the magnet checks the electronics in place, while the quick release kit makes the full wet test practical.
Installation sequence
- Confirm the 2120 on site has the 2-in. Tri Clamp connection and that the vessel socket is a 2-in. NPT.
- Fit the supplied adaptor to the vessel thread using suitable thread sealant approved for the product.
- Place the seal between the faces, offer the 2120 and close the clamp ring, checking the fork does not touch the wall; the fork must have clearance and the solids bridging limit of 0.2 in (5 mm) should be respected.
- Test the switch with the telescopic test magnet (02100-1030-0001) or by wetting the fork.
- Record the new connection in the isolation and permit documents.
Before releasing any joint in service, follow the plant isolation procedure, depressurise and drain the vessel to below the nozzle, and treat the fork as contaminated with process liquid. After refitting, confirm the orientation: the switching point is 0.5 in (13 mm) from the fork tip when mounted vertically, or from the fork edge when mounted horizontally, so the clamp must hold the unit in the intended position. Extended-length forks need support if the vessel has agitation, and the process limit remains 435 psig (30 barg) for Tri Clamp builds.
Maintenance and inspection routine
The 2120 is described by its maker as fit and forget: it needs no calibration, has no moving parts or crevices and gives a heartbeat LED indication of its health, so the accessories around it are the parts most likely to need attention. Inspect the seal at each removal; elastomer seals harden with time and heat. Keep a spare seal on hand: related seals for BSPP connections are listed as 02100-1000-0001 (1-in.) and 02100-1040-0001 (3/4-in.), but the Tri Clamp joint uses the seal in this kit. Wipe the fork and check the tines for coating; the fast-drip shape is designed to shed viscous liquid.
Record the date of each removal in the proof-test log. A quick release joint tempts crews to open it often, so make sure each reassembly includes a fresh visual inspection of the seal groove, a clean seating face and a documented functional test with the magnet. If the vessel is ever changed to a hygienic design, the fitting should be replaced by the polished Tri Clamp 2120 with its 3-A or EHEDG certificate because this kit is explicitly outside those approvals.
Ordering notes
State 02100-1060-0001 and give the existing nozzle size and the 2120 model code so that we can match the connection options. When ordering a 2120 together with the kit, the Tri Clamp connection code 2R is required; the polished-surface codes are not needed for a standard industrial application.
FAQ summary for 02100-1060-0001
The quick release kit does not carry hygienic approvals, does not alter the 2120 electronics and does not include the level switch. It suits vessels with a 2-in. NPT socket. For a 3/4-in. or 1-in. thread, the datasheet instead offers adaptors and seals.
Documents and quotation
The 2120 datasheet that lists 02100-1060-0001 in its spare parts and accessories section is included. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send your RFQ naming 02100-1060-0001, the quantity and the model code of the 2120 it will be used with, plus the delivery point in Oman or the GCC.
Other Models in the Rosemount 2120 Spares Range
Seven Star LLC supplies models from the Rosemount 2120 Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc Cassette | Level Switches | View details |
| Rosemount 02120-7000-0001 2120 Direct Load Cassette | Level Switches | View details |
| Rosemount 02120-7000-0005 2120 8/16 mA Cassette | Level Switches | View details |
| Rosemount 02100-1060-0001 2120 Quick Release Kit | Level Switches | You are viewing this model |
| Rosemount 02120-7000-0003 2120 NAMUR Cassette | Level Switches | View details |
| Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP Tri Clamp | Level Switches | View details |
Datasheets & Documents
- Datasheet Rosemount 02100-1060-0001 2120 Quick Release Kit Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments
Milestones
1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.
Rosemount products we list
FamilyModelsTypical use
Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 02100-1060-0001 2120 Quick Release Kit
Answers from our engineering team on installation, compatibility and integration.
01What is in Rosemount 02100-1060-0001?
The datasheet says the kit contains a 2-in. Tri Clamp, a seal and a quick release device for a 2-in. NPT process connection.
02Which 2120 does the kit fit?
It requires a Rosemount 2120 with the 2-in. Tri Clamp option and an existing 2-in. NPT process connection on the vessel.
03Can I use it on a 3-A or EHEDG hygienic tank?
No. The datasheet states the kit is not approved for use with 3-A or EHEDG products and is not assessed for FDA or ASME-BPE compliant products.
04Why would a plant buy the quick release kit?
It makes inspection, proof-testing and servicing easier because the fork can be released from the vessel by a clamp instead of a threaded joint.
05What is the pressure limit of a Tri Clamp 2120?
The datasheet gives 435 psig (30 barg) for the Tri Clamp connection, with temperature from minus 40 to 302 deg F.