Brand: VEGA
VEGA VEGACAP 67 High-Temperature Capacitive Level Switch 400 °C
Description
A 400 °C capacitive probe for hot bulk solids
The VEGACAP 67 is the high-temperature member of VEGA’s capacitive switch family, a point level sensor for bulk solids with a process temperature rating of -50 to +400 °C. It comes as a rod up to 6 m or a cable up to 40 m, the wetted parts are stainless steel, and the probe insulation is made of ceramic. The sheet describes the transistor (NPN/PNP) version, powered from 10 to 55 V DC, and lists a pressure rating of -1 to +16 bar, which suits hot silos for cement clinker, ash, foundry sand and hot granules rather than pressurised vessels.
Technical specifications
| Parameter | Specification |
|---|---|
| Type | VEGACAP 67, capacitive high-temperature probe, transistor (NPN/PNP) |
| Sensor length | Rod version up to 6 m (19.69 ft); cable version up to 40 m (131.23 ft) |
| Process fitting | Thread from G1½, 1½ NPT; flanges from DN 50, 2″ |
| Process pressure | -1…+16 bar (-100…+1600 kPa / -14.5…+232 psig) |
| Process temperature | -50…+400 °C (-58…+752 °F) |
| Ambient, storage, transport | -40…+80 °C (-40…+176 °F) |
| Operating voltage | 10…55 V DC; max. 0.5 W |
| Load current / voltage loss | < 400 mA / < 1 V |
| Switching voltage / blocking current | < 55 V DC / < 10 µA |
| Switching delay | 0.7 s (on/off) |
| Wetted parts | Stainless steel; ceramic probe insulation |
| Housing | Plastic, stainless steel or aluminium, up to IP67 |
| Approvals (as printed) | Hazardous areas e.g. ATEX and IEC; ship approvals e.g. GL, LRS, ABS |
Handling heat
At 400 °C the electronics cannot sit at the process temperature, so the sheet separates the figures: the ambient, storage and transport temperature stays at -40 to +80 °C while the probe itself is rated to +400 °C. Installers should therefore check the temperature at the housing against the manufacturer’s derating information and the insulation of the vessel wall, since a hot nozzle and a long insulated roof can raise housing temperature beyond the ambient limit.
Selection and ordering
VEGA’s stated benefits are universal use in bulk solids through the wide temperature range, long life with low maintenance, and the flexibility of a shortenable probe. Choose the rod for a short extension from a side wall or the roof, and the cable for deep silos where a point level far below the roof is needed. The maximum pressure is 16 bar, lower than the VEGACAP 65 or 66, so the 67 is chosen for temperature, not pressure.
For an RFQ give the probe type, length, thread or flange, product, temperature and supply. The sheet notes that other electronics versions exist, namely contactless electronic switch, relay and a two-wire type, so please confirm the right version and any ATEX, IEC or ship approval with the manufacturer before ordering.
Related VEGA products: VEGA VEGACAP 64 PTFE Insulated Capacitive Rod Level Switch, VEGA VEGACAP 65 Capacitive Cable Level Switch up to 32 m, VEGA VEGACAP 62 Capacitive Rod Point Level Switch up to 6 m, VEGA VEGACAL 67 Capacitive Probe for Solids up to 400 °C, VEGA VEGAPOINT 21 Compact Capacitive Point Level Switch and VEGA VEGAPOINT 31 Capacitive Level Switch for Powders.
Documents and quotation
The official VEGA VEGACAP 67 (transistor NPN/PNP) specification sheet (34697-EN, version 160112) is attached to this page for download and covers the technical data, dimensions and wiring summarised above.
For a quotation, tell us the medium, tank or channel dimensions, output signal, hazardous-area requirement and quantity. Seven Star LLC, an independent supplier in Muscat, will respond with availability and a commercial offer; other level instrumentation is on our site. Always verify the complete order code against VEGA’s configurator before you place an order.
Datasheets & Documents
- Datasheet VEGA VEGACAP 67 Specification Sheet (34697-EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
VEGA is a German maker of level and pressure instruments. Bruno Grieshaber founded the company in 1959 in Triberg in the Black Forest, and it has been based in Schiltach since 1975, still family owned as VEGA Grieshaber KG. VEGA is best known for radar level sensors: it introduced the first two-wire radar level sensor in 1997 and the first 80 GHz radar sensor for bulk solids, the VEGAPULS 69, in 2015.
Seven Star LLC is an independent supplier listing VEGA radar and guided wave radar transmitters, point level switches, pressure transmitters and signal conditioning instruments for buyers in Oman and the GCC. Sensors are matched from the product code on the type label.
VEGA at a glance
| Origin | Founded by Bruno Grieshaber in 1959 in Triberg, Germany |
|---|---|
| Headquarters | Schiltach, Black Forest, Germany (since 1975) |
| Ownership | Family-owned company: VEGA Grieshaber KG |
| Milestones | First two-wire radar level sensor (1997), first 80 GHz radar for bulk solids, VEGAPULS 69 (2015), VEGAPULS 6X single radar platform for liquids and solids |
| Product families | VEGAPULS radar, VEGAFLEX guided wave radar, VEGASWING and VEGAPOINT switches, VEGACAL capacitive probes, VEGABAR and VEGADIF pressure, VEGAMET and VEGADIS signal conditioning |
VEGA sensor and instrument series
| Series | Type | Typical use |
|---|---|---|
| VEGAPULS 6X, VEGAPULS 69, VEGAPULS 64 | Process radar level transmitters (80 GHz) | Storage and process tanks, reactors with agitators, silos and bulk solids |
| VEGAPULS 11, 21, 31, 42 | Compact radar sensors | Water and wastewater, simple storage tanks; VEGAPULS 42 with IO-Link for machine integration |
| VEGAPULS C 21, C 11, C 22, C 23 | Radar sensors with fixed cable, IP68 | Wet wells, pumping stations, open channels and river levels |
| VEGAFLEX 81, 82, 83, 86 | Guided wave radar (TDR) | Level and interface in liquids, bulk solids, hygienic and high-temperature or high-pressure service (VEGAFLEX 86) |
| VEGASWING 61, 63, VEGAPOINT 21 | Vibrating and capacitive point level switches | Overfill protection, dry-run protection and high or low level alarms |
| VEGACAL 62 to VEGACAL 67 | Capacitive rod and cable probes | Point and continuous level in solids and conductive or adhesive liquids |
| VEGABAR 82, 83, 28, 29, 38 | Pressure transmitters, ceramic or metallic cell | Process pressure and hydrostatic level; compact 18/19 and 28/29/38 versions for utilities |
| VEGADIF 85 | Differential pressure transmitter | DP flow, filter monitoring and level in pressurised vessels |
| VEGAMET 841, VEGADIS 176 | Controller and loop display | Level display, pump control and remote indication of 4-20 mA signals |
Where VEGA instruments are used
VEGA radar sensors measure level in crude oil and product tanks, separators, chemical reactors, cement and aggregate silos, grain stores and water reservoirs. Compact cable radars are widely used in wastewater pumping stations and flood monitoring. Because 80 GHz radar focuses a narrow beam, it can measure past internal structures in a tank, and it is not affected by the temperature, pressure or vapour above the product, which suits hot Gulf storage tanks.
Ordering VEGA instruments: what we need
The product code on the type label (for example PS64.XXXXXXX) fixes the measuring range, antenna or probe, process connection, electronics and approvals. Send it with the serial number. For a new measurement add the medium and its dielectric constant if known, tank or silo height and internals, process pressure and temperature, process connection, output (4-20 mA HART, PROFIBUS PA, Modbus or IO-Link), and any hazardous-area or overfill protection approval required.
Facts checked against VEGA company and product information, October 2026.
Browse VEGA products by category: Level Transmitter, Pressure Instrumentation, Controllers and Data Acquisition.
FAQ
Questions about the VEGA VEGACAP 67 High-Temperature Capacitive Level
Answers from our engineering team on installation, compatibility and integration.
01What is the VEGACAP 67 for?
Point level detection in bulk solids at high temperature.
02What is the process temperature range?
-50…+400 °C (-58…+752 °F).
03What probe lengths exist?
Rod up to 6 m and cable up to 40 m.
04What supply does the sheet version use?
10…55 V DC with a transistor NPN/PNP output.
05What is the pressure rating?
-1…+16 bar (-14.5…+232 psig).


















Reviews