Brand:

Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP Tri Clamp

Description

Overview: the 02100-1010-0001 adaptor boss

Rosemount 02100-1010-0001 is an adaptor boss that converts a 1-in. BSPP thread into a 1 1/2-in. (38 mm) Tri Clamp. The datasheet specifies a 316 stainless steel fitting with an FPM/FKM O-ring. It belongs to the Rosemount 2120 accessory list and is used when a 2120 with a 1 1/2-in. Tri Clamp must be mounted in a vessel that provides only a 1-in. BSPP threaded socket. Instead of welding a new sanitary ferrule to the tank, the adaptor boss lets the clamp-style 2120 use the existing nozzle.

Because it is a plain mechanical fitting, the part is easy to overlook, and its absence often delays a commissioning day; that is why it is worth stocking.

Technical particulars

Parameter Value
Part number 02100-1010-0001
Description Adaptor boss, 1-in. BSPP to 1 1/2-in. (38 mm) Tri Clamp
Fitting material 316 stainless steel
O-ring material FPM/FKM
Thread side 1-in. BSPP (G1)
Clamp side 1 1/2-in. (38 mm) Tri Clamp
Mating 2120 option Process connection code 5R, 1 1/2-in. (38 mm) Tri Clamp
Maximum pressure of Tri Clamp builds 435 psig (30 barg)
Process temperature range of the 2120 minus 40 to 302 deg F
Associated seals 02100-1000-0001 for 1-in. BSPP (carbon fibre with rubber binder)

The table above ties the fitting to the 2120 data; note that the adaptor itself is specified only by its material and size, and its pressure capability in practice is the lower of the fitting and the 2120 rating.

Looking at the dimensions in practical terms, the clamp end is a 1 1/2-in. (38 mm) Tri Clamp, the size the datasheet lists as process connection code 5R, while the thread end uses the 1-in. BSPP form that matches code 1B and the 1-in. seal 02100-1000-0001. The standard 2120 fork length of 1.7 in. (44 mm) applies to threaded builds, whereas Tri Clamp builds start from an extended minimum of 4.1 in. (105 mm), which means that the fork will project further into the tank than a threaded unit and should be checked against nozzle depth before the boss is fitted.

Distinguishing 02100-1010-0001 from neighbouring spares

Three spare parts address connection problems on the 2120 and are easily confused. 02100-1010-0001 converts 1-in. BSPP to a 1 1/2-in. Tri Clamp. Part 02100-1000-0001 is a flat seal for 1-in. BSPP (G1A) connections, made from non-asbestos carbon fibre with rubber binder, and 02100-1040-0001 is the equivalent seal for 3/4-in. BSPP (G3/4A). Part 02100-1020-0001 is a 2-in. Tri Clamp kit with vessel fitting, clamp ring and NBR seal. Only the adaptor boss changes thread type into a clamp.

Use cases

A typical Omani case is a storage tank retrofitted from a threaded float switch to a vibrating fork. The old 1-in. BSPP socket is kept, the adaptor boss is screwed in, and the 2120 clamps on. Others include process skids delivered with threaded nozzles, mobile dosing tanks and chemical day tanks. Wherever a clamp connection lets a technician pull the instrument without tools, this fitting is the bridge between legacy threads and clamp-style fork switches.

Contractors in the GCC often inherit tanks that already carry a BSPP nozzle. A boss makes it possible to retrofit modern clamp-style instrumentation without hot work. Hot work permits, crane time and tank cleaning are the real cost drivers on such jobs, and a small stainless fitting that avoids them is excellent value. It is equally useful in rental dosing skids where the tank nozzle is fixed and the instruments are changed from job to job.

Fitting guidance

  • Thread the boss into the 1-in. BSPP socket with a sealing method suited to the fluid and temperature.
  • Seat the clamp gasket in its groove before closing the clamp ring.
  • Do not exceed the lower of the adaptor and 2120 ratings.
  • Keep the fork clear of the vessel wall and of solids larger than 0.2 in (5 mm) between the tines.
  • Remember the datasheet states hygienic 3-A and EHEDG certificates apply only to specific polished Tri Clamp builds and the accessory is not assessed as part of them.

If the fitting is to be removed regularly, mark the thread engagement so the same depth is restored. After tightening, check the alignment of the clamp flange to the 2120, since a skewed gasket will leak at low pressure. Pressure-test the joint at the plant test pressure where permitted and always stay within the 435 psig (30 barg) Tri Clamp rating that the datasheet gives for the 2120.

Finally, remember that process media compatibility is the purchaser’s responsibility, as the 2120 datasheet states in its material selection note: Emerson cannot evaluate the compatibility of the process fluid with the selected materials. Review the 316 stainless steel and FPM/FKM combination against the chemical list of the tank, including cleaning agents used in CIP routines, before ordering, and quote the material requirement in the RFQ if the duty is aggressive.

Care of the fitting

Check the FPM/FKM O-ring each time the joint is opened and replace it if it looks flattened or damaged. Clean the sealing faces without scratching them, and confirm the O-ring material suits the process liquid, since material selection is the purchaser’s responsibility according to the 2120 datasheet.

Ordering notes for 02100-1010-0001

When requesting 02100-1010-0001, mention the nozzle thread (1-in. BSPP) and the intended 2120 connection code so the match is confirmed. If the vessel has a 3/4-in. BSPP socket instead, a different adaptor or a 2120 with a 3/4-in. thread is needed.

Documents and quotation

The datasheet which lists 02100-1010-0001 within the 2120 spare parts and accessories is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send the RFQ with part number 02100-1010-0001, the required quantity and your delivery location in Oman or the GCC.

Other Models in the Rosemount 2120 Spares Range

Seven Star LLC supplies models from the Rosemount 2120 Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc CassetteLevel SwitchesView details
Rosemount 02120-7000-0001 2120 Direct Load CassetteLevel SwitchesView details
Rosemount 02120-7000-0005 2120 8/16 mA CassetteLevel SwitchesView details
Rosemount 02100-1060-0001 2120 Quick Release KitLevel SwitchesView details
Rosemount 02120-7000-0003 2120 NAMUR CassetteLevel SwitchesView details
Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP Tri ClampLevel SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP Tri Clamp Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP

Answers from our engineering team on installation, compatibility and integration.

01What does Rosemount 02100-1010-0001 do?
It adapts a 1-in. BSPP threaded vessel socket to a 1 1/2-in. (38 mm) Tri Clamp so a clamp-style Rosemount 2120 can be mounted.
02What materials is the adaptor boss made from?
The datasheet lists a 316 stainless steel fitting with an FPM/FKM O-ring.
03Is it the same as the 2-in. Tri Clamp kit?
No. The 2-in. Tri Clamp kit is 02100-1020-0001 with vessel fitting, clamp ring and NBR seal; 02100-1010-0001 is a 1-in. BSPP to 1 1/2-in. adaptor.
04Which seals go with 1-in. BSPP connections?
Seal 02100-1000-0001 is listed for 1-in. BSPP (G1A) and 02100-1040-0001 for 3/4-in. BSPP, both in non-asbestos carbon fibre with rubber binder.
05What temperature range does the 2120 offer?
The Rosemount 2120 is designed for process temperatures from minus 40 to 302 deg F (minus 40 to 150 deg C).