ABB 1SVR405613R3000: the 230 V AC member of the four-contact CR-M group

The CR-M230AC4, order code 1SVR405613R3000, is a plug-in miniature relay whose coil is wound for direct connection to 230 V AC mains control. It switches up to four independent changeover contacts, each rated 6 A at 250 V. Because the coil can sit straight on a phase-neutral control circuit, no control transformer or 24 V supply is needed, which is why this ABB relay appears in the starter panels of pumps, fans and gate drives that are controlled by simple switches and thermostats.

Compared with the 24 V AC relay in the same family, only the coil changes; the contact system, housing and sockets are identical. That makes 1SVR405613R3000 a convenient like-for-like replacement when a 230 V coil has failed in an older cabinet and the socket is still serviceable.

Core characteristics of 1SVR405613R3000

  • Coil rated 230 V AC, 50/60 Hz, 1.6 VA.
  • Operating window of 184 to 253 V AC at 55 degrees C.
  • Coil resistance 16100 ohm at 20 degrees C, plus or minus 10 percent.
  • Four c/o silver-nickel contacts, 6 A thermal current.
  • Impulse withstand 2.5 kV between coil and contacts.
  • Orange test button for AC coils.

1SVR405613R3000 rating overview

Order code 1SVR405613R3000
Type CR-M230AC4
Control voltage Us 230 V AC, 50/60 Hz
Pull-in (make) voltage 184 V AC
Maximum voltage (55 C) 253 V AC
Release threshold 0.2 x Us or higher
Coil resistance 16100 ohm
Coil power 1.6 VA
Contacts 4 c/o, AgNi
Rated thermal current 6 A
Switching voltage, maximum 250 V AC / 250 V DC
Minimum switching 10 V and 5 mA
AC15 at 230 V 1 A
Making current maximum 12 A
Rated insulation voltage 250 V AC
Overvoltage category / pollution degree II / 2 (4-contact)
Operate / release time typ. 10 ms / typ. 8 ms
Ambient range, operation -40 to +55 C
Shock, n/o contact 10 g
Weight 35 g

Why the 230 V coil matters for selection

A relay coil must see a voltage inside its operating window; for the CR-M230AC4 that window is 184 to 253 V AC. In Gulf networks nominal single-phase voltage is 230 V, so the coil sits close to the centre of its range, and brown-outs down to 80 percent still keep it pulled in. If the same panel carries 400 V line-to-line control, the relay must not be placed across two phases.

The release threshold of 0.2 times Us means the relay drops out at about 46 V; a long control cable with high capacitance can hold the coil above that level through leakage, so a bleed resistor or a CR-P/M 82 varistor module for 230 V AC is the tool to use in that case.

Applications

Typical use is the multiplication of a single mains-level command: a thermostat contact that must start two fans, signal a BMS and raise an alarm. Water-pump stations around Oman use it as a float-switch repeater, oil-field camp utilities in the interior use it for lighting-contactor control, and workshop machinery uses it for guard interlocks where a 24 V control supply is not installed. In each case the four contacts let one mains-level signal reach several destinations while the coil circuit stays galvanically separate from the 6 A contact circuits, which is the main reason to use an interface relay in place of paralleling loads on a single switch.

Fitting 1SVR405613R3000 on its socket

Choose a four-contact socket from the CR-M4 series, screw, spring or fork-type, and make sure the terminal arrangement matches the field wiring. Mounting is on 35 mm DIN rail in any orientation. Keep mains-voltage coil wiring physically separated from extra-low-voltage signal wiring in the same duct, because the rated impulse voltage between coil and contacts is 2.5 kV and the clearance is specified accordingly.

Servicing guidance

When the relay is found chattering, check the supply first: a 230 V AC coil needs at least 184 V at the terminals. A stuck test button or discoloured contact windows indicate a worn contact set; at 6 A resistive load the contacts are rated for more than 100000 cycles. Replace the relay without disturbing the socket, and keep one spare on the shelf for every critical mains-controlled circuit, since a failed coil on a pump or ventilation interlock can stop a whole auxiliary system until the part is exchanged. As independent suppliers serving Oman and the GCC, Seven Star LLC is not affiliated with the manufacturer.

Quick answers about 1SVR405613R3000

What voltage does the coil of 1SVR405613R3000 need? 230 V AC at 50 or 60 Hz, with a pull-in voltage of 184 V AC and a maximum of 253 V AC at 55 degrees C.

How does 1SVR405613R3000 differ from CR-M024AC4? Only the coil changes: 230 V AC with a 16100 ohm winding instead of 24 V AC with 158 ohm; contacts and sockets are the same.

What is the contact rating of 1SVR405613R3000? Each of the four c/o contacts has a 6 A thermal current at 250 V and resistive AC12 of 6 A at 230 V.

Can I use 1SVR405613R3000 for DC loads? Yes within limits: the contacts are rated up to 250 V DC, but DC13 inductive capability is only 2 A at 24 V and 0.1 A at 250 V.

Is an LED fitted on 1SVR405613R3000? No. A version with LED carries the letter L at the end of the type code.

Documents and quotation

Download the manufacturer data sheet from this page to check the coil table and load-limit diagrams. To buy 1SVR405613R3000, send an RFQ with the part number, the quantity needed and where it should be delivered; include the socket type when a complete relay-and-socket set is wanted.

Typical Questions From Maintenance Teams

Maintenance engineers replacing a ABB 1SVR405613R3000 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed automation accessories, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.

Other Models in the Abb Cr M Range

Seven Star LLC supplies models from the Abb Cr M range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ABB 1SVR405613R3000 CR-M230AC4 Interface Relay 230 V AC, 4 c/oAutomation AccessoriesYou are viewing this model
ABB 1SVR405618R1000 CR-M024DC4G Gold-Contact Interface Relay 24 V DCAutomation AccessoriesView details
ABB 1SVR405613R4000 CR-M012DC4 Interface Relay 12 V DC, 4 c/oAutomation AccessoriesView details
ABB 1SVR405611R1100 CR-M024DC2L Interface Relay 24 V DC, 2 c/o, LEDAutomation AccessoriesView details
ABB 1SVR405613R0000 CR-M024AC4 Interface Relay 24 V AC, 4 c/oAutomation AccessoriesView details
ABB 1SVR405614R1100 CR-M024DC4LD Relay 24 V DC, LED and DiodeAutomation AccessoriesView details
Datasheets & Documents
  • PDF Datasheet ABB 1SVR405613R3000 CR-M230AC4 Interface Relay 230 V AC, 4 c/o Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

FAQ

Questions about the ABB 1SVR405613R3000 CR-M230AC4 Interface Relay 230

Answers from our engineering team on installation, compatibility and integration.

01What voltage does the coil of 1SVR405613R3000 need?
230 V AC at 50 or 60 Hz, with a pull-in voltage of 184 V AC and a maximum of 253 V AC at 55 degrees C.
02How does 1SVR405613R3000 differ from CR-M024AC4?
Only the coil changes: 230 V AC with a 16100 ohm winding instead of 24 V AC with 158 ohm; contacts and sockets are the same.
03What is the contact rating of 1SVR405613R3000?
Each of the four c/o contacts has a 6 A thermal current at 250 V and resistive AC12 of 6 A at 230 V.
04Can I use 1SVR405613R3000 for DC loads?
Yes within limits: the contacts are rated up to 250 V DC, but DC13 inductive capability is only 2 A at 24 V and 0.1 A at 250 V.
05Is an LED fitted on 1SVR405613R3000?
No. A version with LED carries the letter L at the end of the type code.