Brand:

AUMA SAR 25.1 Modulating Multi-Turn Actuator

Description

Overview

AUMA SAR 25.1 is an AUMA NORM multi-turn actuator for modulating duty (class C, ISO 22153) with a tripping-torque window of 1,000 to 2,000 Nm and 4 output speeds from 4 to 11 rpm. SAR 25.1 is the first modulating AUMA actuator of the heavy 25.1 generation, with a 1,000 to 2,000 Nm tripping-torque window, 800 Nm of modulating torque at S4-25 percent, an F25 flange and a 95 mm stem bore. It weighs approximately 150 kg.

The AUMA SAR 25.1 is supplied by Seven Star LLC, a trusted AUMA supplier for Oman and the GCC, with correct documentation and a regional contact for commissioning.

Operating Principle

A slow modulating actuator, the SAR 25.1 receives short pulses from an AM or AC positioner and holds position by self-locking. Duty is S4 – 25 percent, class C, with 800 Nm modulating torque, 300 starts per hour and a 100 ms minimum pulse.

Engineering Design of the AUMA SAR 25.1

The standard enclosure is IP67 with IP68 as an option, and AUMA states that modulating duty is not possible during immersion. The motor connection is made in a separate terminal compartment. Because the SAR 25.1 is only available at slow speeds, response to set-point changes is slower than on smaller modulating sizes.

Key Features

Specifying the AUMA SAR 25.1 comes down to these points:

  • Heavy modulating multi-turn actuator, 1,000 to 2,000 Nm.
  • Adjustment range: 1,000 to 2,000 Nm per direction, a ratio of 2.0 to 1 between lowest and highest setting.
  • Under S4 – 50 percent duty the limit is 1,400 Nm, which is 70 percent of the top tripping value.
  • Power density works out at roughly 13.3 Nm of maximum torque per kilogram.
  • An illustrative stroke of 55 turns takes about 412 seconds at 8 rpm.
  • In torque class it ranks above the SAR 16.2 and below the SAR 30.1.
  • Dimension drawings and electrical data are covered by separate AUMA sheets.

Selecting the AUMA SAR 25.1

The AUMA SAR 25.1 differs from the SAR 16.2 in several practical ways. The output speed list is short, 4 to 11 rpm only (and 4 and 5.6 rpm are on request). Starts per hour are limited to 300, the pulse duration is at least 100 ms, and the reversal pulse runs from 275 ms at 4 rpm to 130 ms at 11 rpm. Modulating torque is 800 Nm at S4-25 percent and 700 Nm at S4-50 percent.

Typical partners are large control gate valves, heavy angle and globe control valves, sluice gates used for flow and level regulation and large regulating valves in water transmission systems.

A SAR 25.1 is typically bought for a handful of critical regulating points, and its slow speeds, 4 to 11 rpm, are a feature rather than a limitation. Level and flow control gates should not move abruptly, and the long stroke time suppresses water-hammer. Because only 300 starts per hour are permitted, the controller dead band and the filter time constants should be set so that the actuator moves in a few larger steps, not in constant small corrections. When the plant is commissioned, record the as-found modulating torque at several stroke positions as a baseline for later maintenance. During commissioning, record the as-found position feedback and the torque trace for a full stroke, store them with the plant documents, and repeat the measurement at each shutdown, because slowly rising torque is an early warning of packing or stem problems.

Sizing example for the AUMA SAR 25.1

Consider an illustrative regulating gate that needs 700 Nm running torque and 1,500 Nm at the seat. The running torque is under the 800 Nm modulating limit at S4-25 percent, and the seat torque lies within the 1,000 to 2,000 Nm window of the AUMA SAR 25.1. A 60-turn stroke at 8 rpm takes 450 seconds and at 11 rpm about 327 seconds, so a 1 percent change in position takes 3 to 4.5 seconds, which is long enough that the minimum pulse of 100 ms does not limit resolution. These numbers are an illustrative calculation and not AUMA data.

Installation and Mounting of the AUMA SAR 25.1

At approximately 150 kg the AUMA SAR 25.1 needs crane lifting and a verified mounting structure. The F25 flange takes a stem up to 95 mm, the 400 mm handwheel is used for setting and emergency operation, and the enclosure is IP67 as standard, so specify IP68 where flooding is possible. Remember that modulating duty is not possible while the actuator is submerged.

Industrial Applications

Applications in the Gulf include the regulation of large cooling-water flows, flow-control gates at reservoir outlets and level control at wastewater plants. For Omani utilities, a SAR 25.1 on a reservoir or pumping-station regulating valve provides precise continuous positioning that an open-close SA 25.1 cannot offer.

Projects often pair the SAR 25.1 with the AUMA SAR 14.1 multi-turn actuator, the AUMA MATIC AM/AC integral actuator controls and the AUMA SAREx explosion-proof modulating actuator, all available from Seven Star LLC as trusted AUMA supplier.

Neighbouring sizes and counterparts: AUMA SAR 16.2 modulating actuator, AUMA SAR 30.1 modulating actuator, AUMA SA 25.1 multi-turn actuator and AUMA SAREx 25.1 explosion-proof modulating actuator.

Technical Specifications

Data of the AUMA SAR 25.1 from the AUMA technical data sheet for 3-phase AC motors.

Parameter Specification
Model AUMA SAR 25.1
Trip torque range (S4 – 25 percent) 1,000 to 2,000 Nm
S4 – 50 percent limit 1,400 Nm
Permitted modulating torque 800 Nm (S4-25%) and 700 Nm (S4-50%)
Starts/h, max. 300 per hour
Minimum motor pulse 100 ms
Pulse on reversal, max. 275 ms at 4 rpm down to 130 ms at 11 rpm (4 and 5.6 rpm on request)
Output speed steps 4 to 11 rpm at 50 Hz, 4.8 to 13 rpm at 60 Hz, 4 steps (4 and 5.6 rpm on request)
Mounting flange EN ISO 5210 F25; DIN 3210 G4
Rising-stem bore 95 mm
Manual wheel 400 mm
Unit weight approx. 150 kg
Housing protection IP67 (IP68 optional)
Back-drive protection Yes

Setpoint guide for the SAR 25.1 (illustrative calculation, not AUMA data)

Breakaway torque (Nm) Setpoint at +25 percent (Nm)
800 1,000
900 1,125
1,100 1,375
1,200 1,500
1,400 1,750
1,600 2,000

Stroking time for 55 turns at the SAR 25.1 (illustrative calculation, not AUMA data)

rpm at 50 Hz rpm at 60 Hz Seconds for 55 turns at 50 Hz
4 (on request) 4.8 825
5.6 (on request) 6.7 589
8 9.6 413
11 13 300

Request a Quote for AUMA SAR 25.1

Planning a project around the AUMA SAR 25.1? Submit an RFQ listing quantities, supply voltage and valve data, and download the AUMA datasheet from this page.

Datasheets & Documents
  • PDF Datasheet AUMA SAR 25.1 - SAR 30.1 Technical Data Sheet (covers AUMA SAR 25.1) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SAR 25.1 Modulating Multi-Turn Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the torque range of the AUMA SAR 25.1?
The tripping torque of the AUMA SAR 25.1 is adjustable between 1,000 and 2,000 Nm at S4 - 25 percent and up to 1,400 Nm at S4 - 50 percent.
02What modulating performance does the AUMA SAR 25.1 offer?
The AUMA SAR 25.1 is rated for S4 - 25 percent modulating duty, class C, with a modulating torque of 800 Nm (S4-25%) and 700 Nm (S4-50%). It allows 300 per hour, with a minimum pulse of 100 ms and a reversal delay of 275 ms at 4 rpm down to 130 ms at 11 rpm (4 and 5.6 rpm on request).
03Which valve flange and stem size does the AUMA SAR 25.1 fit?
The AUMA SAR 25.1 mounts on an EN ISO 5210 F25 flange (DIN 3210 G4 optional), accepts a rising stem up to 95 mm, has a 400 mm handwheel and weighs approximately 150 kg.
04When should I choose the AUMA SAR 25.1 instead of a neighbouring size?
Select the AUMA SAR 25.1 when valves need 1,000 to 2,000 Nm and the running torque while modulating stays under 800 Nm at S4-25 percent. For heavier duties use the SAR 30.1 with 2,000 to 4,000 Nm, and for lighter duties the SAR 16.2.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SAR 25.1 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.