- Automation & ControlView all 2,612 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AUMA
AUMA SVC-SVCR Globe Valve Actuator with Integral Controls
Description
Overview
AUMA SVC-SVCR is AUMA’s compact electric globe valve actuator range with integral controls, designed for small valves that need a complete, self-contained drive. The SVC version is built for open-close and positioning duty, and the SVCR version for modulating duty, both delivering 10 Nm to 100 Nm of torque from a lightweight aluminium housing. Because the switchgear, power supply unit and DCS interface are built into the actuator, the AUMA SVC-SVCR removes the need for a separate controls cabinet and is configured directly at the actuator.
In Oman and the GCC, Seven Star LLC supplies the AUMA SVC-SVCR to water treatment, power, HVAC, district-cooling and process customers across the Sultanate of Oman and the GCC. For OEM skid builders and valve manufacturers in the region the range is especially attractive, because one compact actuator with a variable-speed brushless motor covers a large range of small globe valves, and our Muscat team can supply it with the correct coupling, interface and fieldbus configuration.
Working Principle of the AUMA SVC-SVCR
The AUMA SVC-SVCR is driven by a brushless, variable-speed motor with soft start and soft stop, whose output speed can be set in nine steps, from 1.6 to 22 rpm on sizes 05.1 and 07.1 and from 0.6 to 8 rpm on size 07.5. The integral power electronics control the motor directly, so the actuator can run slowly near the end positions or at full speed in between, and the controls switch the actuator off automatically when the valve end position is reached, when motor overheating is detected or when a torque overload occurs. Limit switching works via a position transmitter potentiometer and torque switching via electronic current measurement, with both adjustable at the actuator.
On SVC versions, open-close duty is short-time duty S2-15 min in classes A and B, while SVCR versions provide modulating duty S4-40 % in class C with up to 1,800 starts per hour and a positioner that follows a 0/4 to 20 mA set-point. A torque bypass function can increase the set torque to 130 % for a defined time at start-up, which helps unseat valves that have stuck in the seat. Programmable EMERGENCY behaviour lets the valve run to a safe end position on signal.
Engineering Design of the AUMA SVC-SVCR
The range comes in three sizes: SVC/SVCR 05.1 for 10 to 25 Nm, SVC/SVCR 07.1 for 20 to 50 Nm and SVC/SVCR 07.5 for 40 to 100 Nm, with running torques of 13, 25 and 50 Nm respectively and weights of about 7 kg, 10 kg and 10 kg. Valve attachment follows EN ISO 5211 (F05/F07 and F07), with an unbored coupling as standard and finished bores, square or two-flat couplings as options; versions with output drive type A, an LE linear thrust unit or a GS worm gearbox are also possible. Maximum stem strokes are 60 to 70 mm and stem diameters up to 26 mm for rising stems.
Housing parts are aluminium for low weight, with a double-layer powder coating in corrosion class KS and KX as an option. Enclosure protection is IP68, tested for 8 m head of water for up to 96 hours with up to ten operations while immersed. The ambient range is –25 °C to +70 °C, supply is 115 or 230 V single-phase AC at 50 or 60 Hz, and the actuator carries GL approval for environmental categories D and G with EMC class 2. Local controls on the actuator include push buttons and multi-colour indication lights, and a version with local controls on a separate wall bracket is available.
Key Features
The following characteristics define the AUMA SVC-SVCR range:
- Integral controls with switchgear, power supply unit and interface to the DCS eliminate a separate control cabinet.
- A brushless variable-speed motor with soft start gives nine selectable speeds and gentle valve seating.
- Torque from 10 Nm to 100 Nm covers small globe valves, control valves and steam and process valves.
- Four digital inputs, four programmable outputs and 0/4 to 20 mA analogue interfaces provide straightforward integration with PLC and DCS systems.
- Fieldbus options include Profibus DP and Modbus RTU for networked plants.
- Torque bypass up to 130 % helps unseat valves, and torque monitoring runs across the whole travel.
- A lightweight aluminium housing with IP68 protection and KS corrosion protection (KX optional) suits wet and coastal sites.
- Handwheel manual operation for setting and emergency use does not rotate during electric operation.
Industrial Applications
The AUMA SVC-SVCR automates small globe and control valves wherever a self-contained actuator saves cabling and panel space: steam and condensate lines, chilled-water and district-cooling loops, dosing and chemical-feed lines, boiler feed and pressure-control stations, and skid-mounted treatment packages. The modulating SVCR version suits temperature, flow and pressure control loops where 0/4 to 20 mA positioning with a built-in positioner is needed.
In the Sultanate of Oman, such valves are found in commercial and hospitality HVAC plants in Muscat, in district-cooling networks, in the utilities of industrial zones at Sohar and Salalah and in water and wastewater treatment works. In Oman and the GCC, Seven Star LLC distributes the AUMA SVC-SVCR with selection support covering torque, stroke, speed, coupling and bus interface, and can also supply the matching AUMA accessories.
If the AUMA SVC-SVCR is not the closest fit for a valve, see the AUMA SVM-SVMR, AUMA LE linear thrust actuator and AUMA SGC-SGCR for alternatives from the same AUMA family.
Technical Specifications
The table summarises the main data of the AUMA SVC-SVCR from the AUMA product page and the technical data sheet for SVC/SVCR 05.1 to 07.5.
| Parameter | Specification |
|---|---|
| Model | AUMA SVC-SVCR (SVC/SVCR 05.1, 07.1, 07.5) |
| Type of duty | SVC: open-close and positioning, S2-15 min, classes A and B; SVCR: modulating, S4-40 %, class C |
| Torque range | 10 Nm to 100 Nm (05.1: 10–25 Nm; 07.1: 20–50 Nm; 07.5: 40–100 Nm) |
| Output speeds | 1.6 to 22 rpm (05.1, 07.1) and 0.6 to 8 rpm (07.5), adjustable in 9 steps |
| Motor | Variable-speed brushless motor, soft start / soft stop |
| Supply voltage | 1-phase AC 115 V or 230 V, 50/60 Hz |
| Valve attachment | EN ISO 5211 F05/F07 and F07 |
| Interfaces | 4 digital inputs, 4 outputs, 0/4–20 mA in/out, Profibus DP and Modbus RTU options |
| Enclosure protection | IP68 (8 m, 96 h, up to 10 operations) |
| Corrosion protection | KS (KX optional), aluminium housing |
| Ambient temperature | –25 °C to +70 °C |
| Weight | Approx. 7 kg (05.1), approx. 10 kg (07.1 and 07.5) |
Request a Quote for AUMA SVC-SVCR
To request a quotation for the AUMA SVC-SVCR, send Seven Star LLC the valve type, required torque and stroke, desired speed, control signal and fieldbus requirement. Our instrumentation division will configure the actuator with you and provide an RFQ response, and the technical datasheet can be downloaded from this page. We supply AUMA products in Oman and the GCC on request, with lead time confirmed at quotation.
Datasheets & Documents
- Datasheet AUMA SVC/SVCR 05.1 - 07.5 Technical Data Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SVC-SVCR Globe Valve Actuator with Integral
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between the SVC and SVCR versions?
The SVC actuator is designed for open-close and positioning duty (classes A and B, S2-15 min), while the SVCR is designed for modulating duty (class C, S4-40 %) with up to 1,800 starts per hour and a built-in positioner.
02What controls are included in the AUMA SVC-SVCR?
The integral controls contain the switchgear, power supply unit and the interface to the DCS. They switch the actuator off at the end positions, on motor overheating and on torque overload, and parameters are set directly at the actuator.
03Which interfaces and fieldbus options are available?
Standard interfaces include four digital inputs, four programmable outputs and 0/4 to 20 mA signals. Profibus DP and Modbus RTU fieldbus versions are available, and local controls can be mounted separately from the actuator.
04What valves and torques suit the AUMA SVC-SVCR?
The three sizes, SVC/SVCR 05.1, 07.1 and 07.5, cover torques from 10 Nm to 100 Nm on small globe valves with valve attachment to EN ISO 5211 F05/F07.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC is the trusted supplier for AUMA in Oman and the GCC and supplies genuine AUMA actuators with documentation and local technical support.


















Reviews
There are no reviews yet.