Schneider Electric RXM4AB2P7 Harmony RXM Relay 4 C/O 230 V AC
Description
RXM4AB2P7 Harmony RXM miniature relay: what it is and how the code reads
The RXM4AB2P7 is a Schneider Electric product described in the datasheet as: miniature plug in relay, Harmony Electromechanical Relays, 6A, 4CO, with LED, lockable test but to n, 230V AC. The RXM4AB2P7 is a miniature plug-in relay of the Harmony RXM series with four changeover contacts, a 230 V AC coil, an LED indicator and a lockable test button. Seven Star LLC supplies the RXM4AB2P7 in Oman and the GCC as an independent supplier based in Muscat.
Decoding the reference: RXM is the Harmony miniature relay series, 4 stands for four changeover (C/O) contacts, AB is the version with LED and lockable test button, and 2P7 identifies the 230 V AC 50/60 Hz coil (datasheet: 230 V AC 50/60 Hz). Neighbouring references such as RXM2AB2P7 carry two contacts with the same coil voltage.
Technical specifications of the RXM4AB2P7
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RXM4AB2P7 |
| Description | miniature plug in relay, Harmony Electromechanical Relays, 6A, 4CO, with LED, lockable test but to n, 230V AC |
| Range | Harmony Electromechanical Relays |
| Series name | RXM series |
| Product type | Plug-in relay |
| Relay type | Miniature relay |
| Contacts type and composition | 4 C/O |
| Status LED | With |
| Control type | Lockable test button |
| Control circuit voltage (Uc) | 230 V AC 50/60 Hz |
| Rated operational voltage limits | 184 to 253 V AC |
| Conventional enclosed thermal current (Ithe) | 6A |
| Rated operational current (Ie) | 3 A 28 V DC NC IEC; 3 A 250 V AC NC IEC; 6 A 28 V DC NO IEC; 6 A 250 V AC NO IEC; 6 A 277 V AC UL; 8 A 30 V DC UL |
| Minimum switching capacity | 170 mW 10 mA, 17 V |
| Maximum switching capacity | 1500 VA/168 W |
| Maximum switching voltage | 250 V IEC |
| Rated impulse withstand (Uimp) | 2.5 kV 1.2/50 µs |
| Rated insulation voltage (Ui) | 250 V IEC; 300 V CSA; 300 V UL |
| Electrical durability | 100000 cycles resistive |
| Average coil consumption | 1.2 VA 60 Hz |
| Drop-out voltage threshold | >= 0.15 Uc |
| Operating time | 20 ms |
| Reset time | 20 ms |
| Operating rate | <= 1200 cycles/hour under load; <= 18000 cycles/hour no-load |
| Safety reliability data | B10d = 100000 |
| Contact material | AgNi |
| Pin shape | Flat (faston type) |
| Operating position | Any position |
| Net weight | 0.037 kg |
| Degree of protection | IP40 conforming to IEC 60529 |
| Standards | CSA C22.2 No 14; IEC 61810-1; UL 508 |
| Product certifications | UL; Lloyd’s; CE; CSA; GOST; IECEE CB Scheme |
How the RXM4AB2P7 switches its four contacts
When the coil is energised the armature moves all four contact sets together, so four independent circuits change state at once. The datasheet lists the contact composition as 4 C/O, a switching capacity up to 1500 VA/168 W and a minimum switching capacity of 170 mW 10 mA, 17 V, so it suits both power-level and small-signal switching.
Operating time is 20 ms and the electrical durability is stated as 100000 cycles resistive. The LED shows coil energisation and the lockable test button lets an engineer force the contacts for checks without applying coil voltage.
Where the RXM4AB2P7 fits in a control panel
The RXM4AB2P7 plugs into a separate socket, which carries the wiring and holds the relay by a retaining clip. The socket is a separate order item and must match the relay pin shape; the datasheet lists Flat (faston type). Relays in the series are common interposing devices between PLC outputs and heavier loads such as contactor coils and solenoid valves.
Siblings include RXM2AB2P7 (two contacts) and other coil voltages in the same series. They share the same footprint, so a relay can be exchanged for another variant of the same series on an existing socket as long as the coil voltage and contact rating suit the application.
Selection and ordering checklist for the RXM4AB2P7
- Coil voltage: 230 V AC 50/60 Hz; verify AC or DC and frequency.
- Contact rating: 6 A 250 V AC; 6 A 28 V DC per the datasheet, and minimum load for dry-circuit use.
- Number of contacts: four changeover.
- Socket, retaining clip and any marker or surge suppressor options as separate items.
- Ambient temperature: the datasheet gives -40 to 55 °C.
- Duty: very frequent switching shortens life; consider solid-state outputs.
Installation, commissioning and maintenance of the RXM4AB2P7
Plug the relay into its socket, wire the coil and contact circuits to the socket terminals, and fit the retaining clip. The relay weighs 0.037 kg and may be mounted in any position as stated. Keep coil wiring separate from sensitive signal wiring, and use a surge suppressor on DC coils or where long coil cables are used.
Maintenance is by exchange: the relay is a plug-in wear item with a defined electrical life. Use the test button to verify downstream circuits and keep spare relays of the same coil voltage on site. Inspect for contact discolouration and socket heating at routine rounds.
Typical applications of the RXM4AB2P7 in Oman and the GCC
The relay is used in control panels for pumps, fans, valves, alarm and interlock circuits in oil and gas, water and wastewater, desalination and building plants across Oman and the GCC, typically as an interposing relay between a PLC and field devices.
Information to send with an RFQ for the RXM4AB2P7
- Full reference RXM4AB2P7 and quantity
- Coil voltage and frequency
- Load voltage and current
- Socket type and accessories
- Delivery location and timing
Site conditions in Oman for the RXM4AB2P7
Control cabinets in Gulf plants often run hot, because many sit in outdoor kiosks or in rooms where air conditioning is not always reliable. Before you finalise the RXM4AB2P7, check the permitted ambient range and any derating stated by the manufacturer against the real temperature inside your panel, and leave the recommended spacing around the device so that heat can escape. Long cable runs between the field and the marshalling cabinet are common on large sites, so confirm the signal types, wiring limits and earthing arrangement early in the design.
It also helps to standardise on a small number of part numbers across a project. Keeping a few spare RXM4AB2P7 units on site in Oman shortens recovery time after a fault, and documenting configuration settings makes replacement faster for the maintenance team.
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric RXM4AB2P7 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RXM4AB2P7 Harmony RXM Relay 4
Answers from our engineering team on installation, compatibility and integration.
01What contacts does the RXM4AB2P7 have?
4 C/O: four changeover contacts.
02What coil voltage does the RXM4AB2P7 use?
230 V AC 50/60 Hz; the voltage is part of the reference.
03What current can the RXM4AB2P7 switch?
The datasheet lists 6 A 250 V AC; 6 A 28 V DC per contact and a maximum switching capacity of 1500 VA/168 W.
04Does the RXM4AB2P7 need a socket?
Yes, it is a plug-in relay and requires a matching socket, ordered separately.
05What is the operating time of the RXM4AB2P7?
20 ms.