Schneider Electric TeSys Deca LC1D Contactor

Description

Overview

The Schneider Electric TeSys Deca LC1D is the next-generation evolution of the classic TeSys D contactor platform, retaining the same 9–95 A (AC-3) current range and physical footprint while upgrading the internal materials, terminal technology, and short-circuit current rating to current industrial standards. The TeSys Deca LC1D is the specification of choice for new panel builds across Oman and the GCC because it slots directly into legacy TeSys D panel layouts while delivering up to 100 kA SCCR and UL60335-compliant, higher heat and fire-endurance plastics.

Working closely with plant engineers in the region, Seven Star LLC supplies the TeSys Deca LC1D range on request, with technical support for engineering, procurement, and maintenance teams across Oman and the wider GCC. Every unit is sourced through Schneider Electric’s trusted supply channel, so buyers receive current-generation Deca stock with full traceability rather than older TeSys D revisions being cleared through untrusted supply channels.

Operating Principle of the TeSys Deca LC1D Contactor

Mechanically, the TeSys Deca LC1D operates on the same proven electromagnetic principle as its predecessor: an energized coil pulls a moving armature that closes three main power poles simultaneously, and spring return opens them cleanly on de-energization. What changes in the Deca generation is the termination technology – the patented Everlink® connection system, available on 40–65 A ratings, maintains constant clamping force on the conductor over time and temperature cycling, eliminating the periodic re-torquing that traditional screw terminals require in high-vibration or thermally cycled installations.

The Deca platform also carries multi-standard screw terminals compatible with flat, Phillips, and Pozidriv screwdrivers, reducing tooling friction for electricians working across mixed international equipment on the same site. Built-in 1 NO + 1 NC auxiliary contacts continue to provide direct confirmation of pole state to the control system, and the higher SCCR rating means the same physical contactor now tolerates greater short-circuit let-through energy without derating, a meaningful safety margin on sites with aging upstream protection.

Engineering Design of the TeSys Deca LC1D

Reviewing the TeSys Deca LC1D bill of materials, the TeSys Deca LC1D housing uses UL60335-compliant thermoplastics engineered for greater heat and fire endurance than the legacy TeSys D compound, while retaining the same compact 45–85 mm frame widths and DIN-rail or screw mounting so retrofits require no panel redesign. The coil compartment, auxiliary contact interface, and accessory mounting points are dimensionally compatible with the broader TeSys D accessory ecosystem, meaning existing stock of LADN auxiliary blocks, timer modules, and suppressor modules continues to fit.

Coil options span 24 V DC through 240 V AC on the Deca range, and the front label carries a clear model designation alongside a QR code linking to digital product documentation – a practical addition for maintenance teams verifying model and coil ratings during panel audits without pulling a paper datasheet. The overall design intent is straightforward: give panel builders every reason to standardize on Deca going forward without disrupting how a TeSys D-based panel is designed, wired, or serviced today.

Key Features

The TeSys Deca LC1D platform brings measurable upgrades over the legacy TeSys D range while preserving footprint compatibility, summarized below:

  • Covers the same 9–95 A (AC-3) range as TeSys D, on an identical physical footprint for drop-in retrofit.
  • Up to 100 kA SCCR rating provides greater short-circuit withstand margin than earlier-generation contactors.
  • Everlink® termination on 40–65 A ratings maintains constant terminal clamping force without re-torquing.
  • UL60335-compliant plastics deliver higher heat and fire endurance for demanding panel environments.
  • Multi-standard screw terminals accept flat, Phillips, and Pozidriv drivers for faster field termination.
  • Built-in 1 NO + 1 NC auxiliary contacts confirm pole state for interlocking and remote monitoring.
  • Full accessory compatibility with the existing TeSys D auxiliary block, timer, and suppressor ecosystem.
  • QR-coded front label links directly to digital datasheets for fast field verification.

Industrial Applications

Across Oman and the GCC, the TeSys Deca LC1D is increasingly the default specification for new motor control panels in district cooling plants, commercial building services, and water and wastewater treatment facilities in and around Muscat, where designers want the higher SCCR margin without changing established panel layouts. Its footprint compatibility with legacy TeSys D also makes it the natural replacement contactor when maintenance teams retrofit aging panels rather than fully re-engineering them.

With fast quotation turnaround and technical support, Seven Star LLC distributes the TeSys Deca LC1D to EPC contractors and panel integrators serving the Sohar and Salalah economic zones, where new petrochemical and logistics facility builds specify current-generation contactor platforms as standard practice. The same range appears in hospitality and healthcare electrical rooms across the Sultanate, where the improved fire-endurance plastics offer a genuine safety margin in enclosed switchgear rooms.

Technical Specifications

The following table summarizes the key parameters of the TeSys Deca LC1D contactor range.

Parameter Specification
Model LC1D09BD – LC1D95 (TeSys Deca range)
Rated Operational Current (AC-3) 9 A to 95 A
Rated Operational Voltage Up to 690 V AC
Short-Circuit Current Rating (SCCR) Up to 100 kA
Poles 3P (3 NO)
Auxiliary Contacts 1 NO + 1 NC built-in (expandable)
Coil Voltage Range 24 V DC – 240 V AC
Terminal Type Screw clamp, Everlink® on 40–65 A ratings
Mounting 35 mm DIN rail or screw fixing
Enclosure Material UL60335-compliant, high heat/fire endurance thermoplastic
Standards IEC 60947-4-1, UL 508, CSA C22.2 No.14

Request a Quote for Schneider Electric TeSys Deca LC1D Contactor

Panel builders and facility engineers in Oman and the GCC can request a formal RFQ for the TeSys Deca LC1D contactor directly from Seven Star LLC, with lead time confirmed at quotation and full technical datasheets available on request. With engineering support in Muscat, our instrumentation and automation division supports migration from legacy TeSys D to Deca and sizing for new panel builds – contact Seven Star LLC today to confirm availability and lead time.

Other Models in the Schneider Electric TeSys Motor Control Range

Seven Star LLC supplies models from the Schneider Electric TeSys Motor Control range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric TeSys Deca LC1D ContactorContactors & Overload RelaysYou are viewing this model
Schneider Electric TeSys D LC1D ContactorContactors & Overload RelaysView details
Schneider Electric TeSys F LC1F400 ContactorContactors & Overload RelaysView details
Schneider Electric TeSys Giga LC1G High-Power ContactorContactors & Overload RelaysView details
Schneider Electric TeSys LRD Thermal Overload RelayContactors & Overload RelaysView details
Schneider Electric TeSys Ultra Overload RelayContactors & Overload RelaysView details
Schneider Electric TeSys Vario Disconnect SwitchCircuit BreakersView details
Schneider Electric TeSys Q Motor Disconnect SwitchCircuit BreakersView details
Schneider Electric TeSys Track Condition Monitoring SystemMotor Soft StartersView details

Related Products

Datasheets & Documents
  • PDF manual Schneider Electric TeSys D Contactor LC1D09-D38 Instruction Sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric TeSys Deca LC1D Contactor

Answers from our engineering team on installation, compatibility and integration.

01What is different about the TeSys Deca LC1D compared with the original TeSys D?
The TeSys Deca LC1D keeps the same current range and footprint as TeSys D but adds up to 100 kA SCCR, UL60335-compliant fire-resistant plastics, and Everlink terminal technology on select ratings for better long-term connection reliability.
02Will a TeSys Deca LC1D fit in a panel built for the original TeSys D?
Yes. The Deca range shares the same 45-85 mm frame widths, mounting pattern, and accessory interface as classic TeSys D, so it fits existing panel layouts and accepts existing auxiliary blocks and timer modules.
03What is Everlink termination on the TeSys Deca LC1D?
Everlink is a patented terminal technology available on 40-65 A Deca ratings that maintains constant clamping force on the conductor across temperature cycling, removing the need for periodic terminal re-torquing.
04What coil voltages are available for the TeSys Deca LC1D?
Coil options on the Deca range span 24 V DC through 240 V AC, covering the majority of control voltages used across GCC industrial and building-services panels.
05Is Seven Star LLC an experienced supply partner for Schneider Electric products?
Yes, Seven Star LLC is an experienced supplier of Schneider Electric in Oman and the GCC, supplying genuine TeSys Deca LC1D contactors on request with manufacturer documentation and technical support.