Endress+Hauser FTL63 Liquiphant Premium Hygienic Level Switch

Description

Endress+Hauser FTL63 Liquiphant premium hygienic level switch

The Endress+Hauser FTL63 is the premium hygienic Liquiphant vibronic point level switch. It is developed for food, beverage and life-science processes and combines a modular housing, a pipe extension up to 3 m and an extended list of certificates and functions, including density and concentration measurement variants and safety-integrity capability. In the same family as the FTL43 it detects liquid with a tuning fork, but the FTL63 targets applications where more diagnostics, more approvals and longer probes are needed. Seven Star LLC supplies the FTL63 in Oman and the GCC as an independent supplier in Muscat and quotes it against your process and communication needs.

FTL63 technical specifications

Parameter Specification
Manufacturer / part number Endress+Hauser / Liquiphant FTL63
Measuring principle Vibronic tuning fork point level
Process temperature −50 to +150 °C
Process pressure Vacuum to 64 bar
Minimum density 0.5 g/cm³ (0.4 g/cm³ optional)
Ambient temperature −40 to +70 °C up to 90 °C process
Supply DC 10.5 to 35 V; DC 10.5 to 30 V for Ex i
Output SIO 8/16 mA or 4 to 20 mA HART; PROFINET over Ethernet-APL
Extension Up to 3 m
Wetted materials 316L (1.4404 / 1.4435)
Functional safety SIL 2, SIL 3 with homogeneous redundancy (HART version)
Hygienic 3-A, EHEDG, ASME BPE; FDA / EC 1935/2004 materials conformity

How the FTL63 works and what it can report

The fork is excited by a piezo element, and the electronics evaluate frequency and amplitude. Covered by liquid, the frequency drops and the output switches. Because the evaluation is digital, the FTL63 also provides diagnostics, Heartbeat Technology functions for in-place verification and, in versions that include a density selection switch, behaviour for liquids above 0.7 g/cm³. The wide choice of electronics covers HART and PROFINET over Ethernet-APL (10BASE-T1L), with PROFINET PA Profile 4.02 diagnostics.

FTL63 data: temperature, pressure and ranges

Process temperature is −50 to +150 °C and pressure ranges from vacuum to 64 bar. Minimum density is 0.5 g/cm³ (0.4 g/cm³ optional). Ambient temperature is −40 to +70 °C up to a process temperature of +90 °C, reduced beyond that. The supply is DC 10.5 to 35 V for non-Ex, Ex d and Ex e versions and DC 10.5 to 30 V for Ex i. The HART output offers SIO mode 8/16 mA or 4 to 20 mA with NAMUR NE43 alarm levels as factory setting. Wetted parts are 316L (1.4404 or 1.4435) with the fork in 1.4435.

Functional safety and approvals of the FTL63

When ordered with HART, the device was developed to IEC 61508 and is suitable for overfill and dry-run protection systems up to SIL 2, or SIL 3 with homogeneous redundancy. The manufacturer publishes a separate Functional Safety Manual. Explosion-protection data are issued as separate Ex documents with the device, and hazardous-area versions are covered by those documents; do not assume an Ex rating without checking the product order code. Hygienic certificates and materials conformity (3-A, EHEDG, ASME BPE, EC 1935/2004, FDA) are listed in the document.

Choosing the FTL63 version and connection

Select the electronics, housing, extension length (up to 3 m), surface finish (mechanical or electropolished) and process connection. The hygienic range includes Clamp, Varivent, DIN 11851, aseptic unions and flanges. Check whether you need the density and concentration version and whether the LED module or Bluetooth operation should be included.

Installing and testing the FTL63

Place the fork where it is wetted reliably in the intended switching state and keep it out of strong flow and filling streams. In pipes the fork direction mark must align with the flow so the liquid drains from the fork. For safety functions follow the proof-test and commissioning procedure in the safety manual, including a documented test of the switching function after installation and at regular intervals.

FTL63 applications in Oman and the GCC

Premium hygienic switches are used on dairy and beverage tanks, aseptic lines, pharmaceutical mixing vessels and CIP return lines. Where the plant needs a certified overfill protection on a hygienic tank, the SIL-rated FTL63 with HART fits better than the compact FTL43. In hot climates the ambient limit of 70 °C with reduction at high process temperature matters for sun-exposed tanks; use a sun shield.

FTL63 relationship to the FTL43 and FTL64

The FTL63 offers a longer extension (3 m versus 1.5 m), SIL capability, density and concentration options and PROFINET over Ethernet-APL. The FTL43 targets compact installations, and the FTL64 is aimed at higher-temperature industrial service. Select by process and approval, not by name.

Information to send with an FTL63 RFQ

  • Medium, density and viscosity range
  • Process temperature, pressure, cleaning cycle
  • Probe length and connection type
  • HART or PROFINET over Ethernet-APL
  • SIL, Ex and hygienic certificate needs
  • Quantity and delivery location

Maintenance of the FTL63 and proof testing

Inspect the fork and process seal at every shutdown, record the nameplate order code, and keep a spare seal on site. Where the FTL63 is part of a safety function, schedule the proof test interval defined in the safety manual and keep the results with your plant records.

If a replacement is needed, a device with the same order code can be fitted and the switching point re-verified in the same way as at first commissioning.

Documents and quotation

A copy of the manufacturer technical information for the FTL63 is attached on this page so you can check ranges, connections and ordering codes against your specification. The attached document is the HART, PROFIBUS and related electronics version of the technical information.

Send the full order code or the process data (fluid, temperature, pressure, line size or tank data, output and approvals) and Seven Star LLC will prepare a quotation and confirm lead time. We are an independent supplier in Muscat and do not represent the manufacturer.

Other Models in the Eh Liquiphant Hyg Range

Seven Star LLC supplies models from the Eh Liquiphant Hyg range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser FTL43 Liquiphant Hygienic Point Level SwitchLevel InstrumentationView details
Endress+Hauser FTL63 Liquiphant Premium Hygienic Level SwitchLevel InstrumentationYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser FTL63 Technical Information Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser FTL63 Liquiphant Premium Hygienic

Answers from our engineering team on installation, compatibility and integration.

01What distinguishes the FTL63 from the FTL43?
The FTL63 is the premium hygienic version, with up to 3 m extension, modular housing, SIL capability and density or concentration options.
02What SIL level does the FTL63 reach?
With HART it was developed to IEC 61508 for overfill and dry-run protection up to SIL 2, and SIL 3 with homogeneous redundancy.
03What process conditions are allowed?
−50 to +150 °C and vacuum to 64 bar, for liquids with density from 0.5 g/cm³ (0.4 optional).
04Which communication choices exist?
HART with SIO or continuous 4 to 20 mA, and PROFINET over Ethernet-APL using 10BASE-T1L.
05Is it available with an explosion-proof rating?
Hazardous-area versions are described in separate Ex documents; confirm the exact order code and certificate before ordering.