- Vibration Monitoring
- PLC & I/O Cards
- Industrial Communications
- Automation Accessories
- Controllers & Data Acquisition
- AC Drives
- Isolator & Barrier
- Industrial Computers
- Encoders
- Automation Software
- Safety Switches & Guard Locking
- HMI Displays
- Motor Soft Starters
- Servo Drives
- CCTV & Security
- Robotics
- Machine Vision
- Pneumatic Cylinders
Pepperl+Fuchs
Two specialties define Pepperl+Fuchs, founded in 1945 and headquartered in Mannheim, Germany: industrial sensors for automation, and interface and protection equipment for hazardous areas. Many control cabinets in process plants contain rows of its isolators. Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Read more about Pepperl+Fuchs ↓ Brand profile
About Pepperl+Fuchs
- Founded
- 1945
- Headquarters
- Mannheim, Germany
- Speciality
- Industrial sensors and explosion protection
- Listed with us
- 9 products in 4 categories
Two specialties define Pepperl+Fuchs, founded in 1945 and headquartered in Mannheim, Germany: industrial sensors for automation, and interface and protection equipment for hazardous areas. Many control cabinets in process plants contain rows of its isolators.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs across GCC oil and gas sites.
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Pepperl+Fuchs products by category
Request a Quote for Pepperl+Fuchs Products
Looking for Pepperl+Fuchs parts not listed here, or pricing for a project? Send us the part numbers and quantities. Seven Star LLC sources genuine Pepperl+Fuchs products for customers across Oman and the GCC and replies with a formal quotation.
- Genuine OEM products
- Supply across Oman & the GCC
- Formal quotation from our sales team
Free, no-obligation quotation · takes about 1 minute
Other enquiries: [email protected] · WhatsApp
Frequently Asked Questions
Both are isolated barrier families for intrinsically safe signals. K-System modules such as the KFD2 types clip onto DIN rail and are wired individually, often with a power rail. H-System modules such as the HiD2030 plug into termination boards that carry the system cable to the control system. The two formats are not interchangeable, so match what is already in the cabinet.
The first block identifies the housing and supply type, the middle block the function (UT2 is the universal temperature converter) and the Ex suffix shows an intrinsically safe version with its channel count. Suffixes after that select variants. Copy the whole designation from the front label, since near-identical codes exist for non-Ex and single-channel versions.
NJ2-12GK-SN is a NAMUR inductive sensor in a 12 mm threaded housing with a 2 mm sensing distance, and SN marks the manufacturer's safety-function sensor design. It must be paired with a suitable NAMUR isolating switch amplifier. If it is part of a safety loop, check the functional safety data in the manufacturer's documentation for both devices.
Approvals are specific to each model and are listed on its datasheet and certificate. Interface modules and Ex mobile devices are issued with hazardous-area certificates by the manufacturer, and the marking on the label states the zone or division. Tell us the certification scheme your site requires and we will check the exact model before quoting.
No. Seven Star LLC is an independent supplier and is not a distributor, agent or partner of Pepperl+Fuchs. We source the products through commercial channels, check the model designation against the manufacturer's documentation, and provide the manufacturer's datasheet and the certificates the manufacturer issues with the order on request.



