Brand:

GESTRA NRG 26-21 Capacitance Level Electrode PN 40

Description

GESTRA NRG 26-21 Capacitance Level Electrode PN 40: overview

The GESTRA NRG 26-21 is a capacitance level electrode for continuous water level monitoring in steam boilers, pressurised hot-water installations and condensate or feedwater tanks. It works with the NRV 2-31 pre-amplifier, which turns the capacitance change into a level-proportional signal.

Used with the NRS 2-.. level switches or the NRR 2-.. level controllers, it provides control with MIN and MAX alarms. Because the principle is capacitive, the electrode can also measure in non-conductive liquids such as fuel oil.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list the NRG 26-21 for buyers who need an exact GESTRA type for a repair, a replacement or a new project and want a clear technical summary before asking for a quotation. The facts below are condensed from the manufacturer datasheet, and where a value is not stated there, we leave it out rather than guess.

Level and conductivity electrodes sit at the heart of every boiler protection and control loop. A boiler house runs for years between shutdowns, so the sensor is often one of the first parts to need replacement, and buyers usually need the exact type designation to be sure the new part fits the existing standpipe, thread and evaluation unit. Quote the full designation NRG 26-21 together with the nameplate data of the old unit, and we can check the details before a quotation is prepared.

Key features of the NRG 26-21

  • Continuous capacitance measurement; the rod length sets the measuring range
  • Usable in conductive and non-conductive fluids
  • Three sensitivity ranges selected on the pre-amplifier
  • Level-proportional output of 0 to 7 VDC
  • PTFE rod insulation and 1.4571 screw-in body
  • Weather protection cover needed for outdoor installation

GESTRA NRG 26-21 technical specifications

Parameter Value
Type NRG 26-21 with NRV 2-31 pre-amplifier
Nominal pressure PN 40
Service pressure 32 bar at 238 °C
Mechanical connection Screwed G 3/4 A, ISO 228
Screw-in body 1.4571 (X6CrNiMoTi17-12-2)
Rod insulation PTFE
Pre-amplifier supply 12 VDC
Sensitivity range 1 Water of at least 20 µS/cm
Sensitivity range 2 Water of at least 0.5 µS/cm
Sensitivity range 3 Fuel oil EL, permittivity 2.3
Output 0 to 7 VDC, level proportional
Pre-amplifier housing PA6 GF30 black / PSU grey transparent, EPDM cover gasket
Electrical connection 3-pole screw terminal, cable gland M16
Protection IP 65 to DIN EN 60529
Max. ambient temperature 70 °C
Weight Approx. 1.8 kg for L = 1000 mm

All values above come from the manufacturer datasheet for the NRG 26-21 and its family. Related types named in the datasheet, such as NRV 2-31 pre-amplifier, have their own ratings, so check the type designation before ordering.

Typical applications in Oman and the GCC

Process steam and hot water are everywhere in the region. Food and beverage plants, hospitals, hotels and laundries run package boilers; refineries, petrochemical sites and utility stations in Oman and the wider Gulf operate larger steam generators and thermal desalination units. In hot and dusty climates, cabinet temperature, cable routing and the condition of connectors deserve extra attention, and a spare unit on the shelf can shorten an outage considerably.

  • Continuous level measurement in boiler drums as part of feedwater control
  • Condensate and feedwater tank level control
  • Fuel oil day tanks where non-conductive liquids are measured
  • Replacement of electrodes in NRR 2-5. and NRS 2-5. control loops

Selection and compatibility notes for the NRG 26-21

  • Compatible switches and controllers per the datasheet: NRS 2-50, NRS 2-51, NRR 2-50, NRR 2-51, NRR 2-52 and NRR 2-53.
  • Specify the installed length; it determines the measuring range and must not be shortened later.
  • Choose the sensitivity range that matches the liquid on the pre-amplifier.
  • Add a weather cover for outdoor installation.

If you are unsure which variant of the NRG 26-21 you have, photograph the nameplate and send the full text. The type, the pressure class or supply voltage and any suffix letters are what we need to match the right part.

Planning a spare is straightforward if you note a few details when the plant is down. Record the type designation, the installed length, the thread and the cable connection, and keep a photograph of the nameplate. Because the switchpoint or measuring range of an electrode depends on its rod length, a part of the right type but the wrong length will not behave like the part it replaces. For a critical boiler, many operators keep one spare electrode of each installed type and length, which makes a failed test during an inspection a short job instead of a long wait.

Installation and commissioning

  • The electrode may share a protection tube or external level pot with one GESTRA limiter or high-level electrode (inside diameter 100 mm).
  • When fitted inside the vessel, keep at least 40 mm from the upper vent hole.
  • Do not exceed 45 degrees of inclination, and limit the rod length to 688 mm when inclined.
  • Do not cut the electrode rod.
  • Use screened control cable such as LiYCY 4 x 0.5 mm2, up to 100 m.
  • Do not use in potentially explosive areas.

Always follow the manufacturer manual and the safety rules of your site and boiler inspection body during installation and commissioning. Isolate and depressurise the plant before any work on pressure-bearing parts and lock off the electrical supply before opening a terminal box or cabinet.

Maintenance and service

  • Recheck calibration and range settings after any maintenance on the electrode.
  • Inspect the PTFE insulation and cable gland for damage.
  • Verify the level reading against the gauge glass at every inspection.

Record each test of the NRG 26-21 in the plant log. A written history of tests and replacements helps the inspector, shortens fault finding and gives you a clear basis for deciding when a spare should be ordered.

Related products and ordering notes

Matching controllers are the NRR 2-50 to NRR 2-53 and the NRS 2-50 and NRS 2-51. Send the required rod length and operating pressure with your inquiry.

When you order a NRG 26-21, state the quantity, the full type designation and any option or length that applies, and tell us the plant tag or project if you have it. Lead times depend on stock and on the manufacturer, so please ask early for planned shutdowns.

Frequently asked questions

What measuring principle does the NRG 26-21 use? Capacitance measurement, with the NRV 2-31 pre-amplifier converting level changes into a level-proportional signal.

Can it measure non-conductive liquids? Yes. The datasheet lists a range for fuel oil EL and says it can be used in conductive and non-conductive fluids.

What is the pressure rating? PN 40, with a service pressure of 32 bar at 238 °C.

May I shorten the rod? No. The datasheet says not to cut the electrode rod.

Which controllers work with it? NRS 2-50, NRS 2-51, NRR 2-50, NRR 2-51, NRR 2-52 and NRR 2-53.

Documents and quotation

The manufacturer datasheet for the NRG 26-21 is available from us on request and is attached to this listing where file size allows. To receive a quotation, send an RFQ with the part number NRG 26-21, the quantity and your delivery location in Oman or the GCC, and our team will reply with availability and lead time.

Datasheets & Documents
  • PDF Datasheet GESTRA NRG 26-21 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

GESTRA is the German steam and condensate specialist behind the UNA ball float steam traps, the MPA blowdown valves and a long line of boiler level and conductivity controls. It was founded in Bremen in 1902 by Gustav F. Gerdts, and has been part of Spirax Sarco since 2017.

Seven Star LLC is an independent supplier in Muscat. We list GESTRA steam traps, blowdown valves and boiler control equipment, and supply GESTRA parts and spares to boiler houses and process plants in Oman and the GCC.

GESTRA company profile

Established 29 October 1902, Bremen, Germany, by Gustav Friedrich Gerdts; renamed Gustav F. Gerdts KG in 1907
Ownership history Became a stock corporation (GESTRA AG) in 1987, was taken over by Flowserve in 2002, and has been part of the Spirax Sarco group since 2017
Product families Steam traps, non-return and check valves, boiler blowdown valves, control valves, and boiler control electronics for level, conductivity and temperature
Applications Steam boilers, steam distribution and condensate return in process plants, power stations, hospitals, food and textile plants

Milestones

  • 1902: Gustav Friedrich Gerdts founds the company in Bremen on 29 October.
  • 1907: The company is renamed Gustav F. Gerdts KG.
  • 1987: It becomes a stock corporation, GESTRA AG.
  • 2002: Flowserve takes over GESTRA.
  • 2017: GESTRA becomes part of the Spirax Sarco group.

GESTRA products we list

Series Type What it does
UNA 45, UNA 16, UNA 38 Ball float steam traps Continuous condensate discharge from heat exchangers and process equipment; the UNA 38 is the high-pressure version (PN 100)
BK 45 Bimetallic steam trap Robust trap for steam main drainage and tracing, resistant to water hammer
MK 45, TK 23, SMK 22-81 Thermostatic steam traps Air venting and condensate discharge; the SMK 22-81 is the sanitary version for clean steam
MPA 46 Rapid-action blowdown valve Short, intermittent bottom blowdown that removes sludge from the boiler
NRS 1-54, NRR 2-50, NRR 2-60, NRGT 26-2 Boiler level controls Water level limiting, feedwater control and continuous level measurement
LRGT 16-1, LRR 1-50 Conductivity measurement and control Keeps boiler water conductivity in range through continuous blowdown
TRS 5-50 Safety temperature limiter SIL 3 temperature limiting for boilers and hot water systems

The type of steam trap follows the duty. Ball float traps discharge condensate as soon as it forms, which suits heat exchangers with changing loads. Thermostatic and bimetallic traps hold condensate back slightly and suit steam mains, tracing and air venting. On the boiler itself, GESTRA level and conductivity electronics work as a system: electrodes or transmitters in the boiler, controllers in the panel, and the feedwater and blowdown valves they drive.

Where GESTRA products are used

In Oman and the GCC, GESTRA equipment is used in boiler houses of refineries, petrochemical and fertiliser plants, power and desalination stations, food and beverage plants, laundries, hotels and hospitals.

Ordering GESTRA parts: what we need

Send the type designation, pressure rating (PN) and connection size (DN), the end connection (flanged, screwed or socket weld), the operating pressure and condensate load for steam traps, and the supply voltage and bus type (CAN bus, 4-20 mA) for control equipment. For electrodes, add the insertion length.

Facts checked against GESTRA company history and Bremen city records, October 2026.

FAQ

Questions about the GESTRA NRG 26-21 Capacitance Level Electrode PN 40

Answers from our engineering team on installation, compatibility and integration.

01What measuring principle does the NRG 26-21 use?
Capacitance measurement, with the NRV 2-31 pre-amplifier converting level changes into a level-proportional signal.
02Can it measure non-conductive liquids?
Yes. The datasheet lists a range for fuel oil EL and says it can be used in conductive and non-conductive fluids.
03What is the pressure rating?
PN 40, with a service pressure of 32 bar at 238 °C.
04May I shorten the rod?
No. The datasheet says not to cut the electrode rod.
05Which controllers work with it?
NRS 2-50, NRS 2-51, NRR 2-50, NRR 2-51, NRR 2-52 and NRR 2-53.