Brand:

AUMA GS 50.3 Part-Turn Worm Gearbox, 350 Nm, F05-F10

Description

AUMA GS 50.3: the smallest worm gearbox of the GS line

AUMA GS 50.3 is the lightest part-turn gearbox in the GS 50.3 to GS 250.3 range, at 7.0 kg. It converts the multi-turn rotation of a handwheel or of a small electric actuator into a 90 degree swing for butterfly, ball and plug valves that need up to 350 Nm at the valve shaft. A single ratio of 51:1 means the input shaft makes 12.75 turns for a quarter turn, which is a gentle gear for manual positioning and a good match for the modulating duty that the gearbox is designed for.

How the ratio works in practice

The conversion factor of 17.9 relates the valve torque to the input torque. A valve needing 350 Nm therefore requires about 20 Nm at the input shaft, and that is exactly the maximum input torque of the GS 50.3. For the modulating limit of 125 Nm the input torque is roughly 7 Nm. Because the gear is self-locking at standstill, the valve stays in position while the actuator rests, although strong vibration can overcome this and a brake is required if safe holding is a requirement.

Datasheet figures for GS 50.3

Parameter Value
Type GS 50.3, part-turn worm gearbox
Maximum valve torque 350 Nm
Modulating valve torque 125 Nm
Valve flanges F05, F07, F10 (EN ISO 5211)
Reduction ratio 51:1 (factor 17.9)
Turns of the input shaft for 90 degrees 12.75
Input shaft diameter 16 mm
Input flange for multi-turn actuator F07 (F10)
Maximum input torque 20 Nm
Strength of the end stop at the input 250 Nm
Weight 7.0 kg
Handwheel diameters 160, 200 or 250 mm
Gearbox type Part-turn worm gearbox for modulating duty, bronze worm wheel
Duty Intermittent duty S4-25 percent, class C per EN 15714-2 (modulating)
Maximum input speed 215 rpm
Self-locking At standstill under normal service conditions; strong vibration may cancel it and a separate brake is needed if safe braking is required
End stops Positive for both end positions, travelling nut, sensitive adjustment
Swing angle (standard) Fixed between 10 and 100 degrees, set to 92 degrees at the factory unless ordered otherwise
Enclosure IP68 (8 m head of water); IP68-20 (20 m) as option
Ambient range Minus 40 to plus 80 degrees C; options minus 60 to plus 60 and 0 to plus 120
Lifetime (AUMA load spectrum, duty class 2) 1.2 million modulating steps for 90 degree swing
Corrosion protection and coating KS standard, KX optional; double-layer powder coat in silver-grey

Mounting an actuator

The input mounting flange for a multi-turn actuator is F07, with F10 available in brackets in the table. A small multi-turn actuator with an F07 or F10 flange can be fitted, but its torque switch must be set so that the 20 Nm input limit of this gearbox is never exceeded, since many small actuators can trip at higher values. The end stop strength for input-side operation is 250 Nm.

Valve types and sites

The GS 50.3 is used for small butterfly valves, ball valves and plug valves, as well as for dampers in HVAC and flue systems that need specific sizing. In the Gulf, chilled water and desalination plants use gearboxes of this size on dosing and bypass valves, where a modulating signal moves the valve in small steps. Standard end stops protect the valve when the manual drive is turned too far.

GS 50.3 compared with GS 63.3 and GS 80.3

GS 63.3 delivers 700 Nm on F10 / F12 with 12 kg and a 20 mm input shaft. GS 80.3 delivers 1,400 Nm on F12 / F14 with 16 kg and 13.25 turns for 90 degrees. The GS 50.3 is therefore the right choice below 350 Nm, and it has the smallest input shaft (16 mm), the lowest weight and the smallest handwheel (160 to 250 mm).

Swing angle, indication and options

The standard swing angle is fixed between 10 and 100 degrees and delivered at 92 degrees unless stated otherwise. Options provide adjustable bands such as 10 to 35 degrees, 35 to 60, 60 to 80, 80 to 100 and further bands up to 190 degrees. The pointer cover gives continuous position indication, while a protection cover without indicator can be fitted for buried service. For this size the sealed pointer cover options are not available.

Handwheel, covers and environment of the GS 50.3

Manual operation uses an aluminium handwheel with ball handle, electrophoretic coating and diameter selected from 160, 200 and 250 mm. Options include a cast iron wheel, a lockable wheel, a chainwheel and the WSH limit switching device for position and end-position signalling. Any mounting position is allowed. The ambient range of minus 40 to plus 80 degrees C can be changed by option to minus 60 to plus 60 or 0 to plus 120 degrees C. IP68 protects against water up to 8 m, with IP68-20 for 20 m as an option.

Valve attachment details of the GS 50.3

The valve flange follows EN ISO 5211 with spigot rings as an option in this size class, and plane flanges are realised by recesses. Two bores for parallel pins, shifted by 180 degrees, are an option, although the pins are not part of the delivery. The splined coupling is supplied without bore as standard and can be finished with a bore and keyway, a square bore or a two-flat with grub screw.

Check that the valve flange (F05, F07 or F10) and the shaft fit the coupling; machine the bore and keyway or choose a square or two-flat form. The housing is cast iron GJL-250 with spheroidal cast iron as an option. Inspect seals and breather yearly and renew grease according to the manufacturer’s instructions.

For GS 50.3 give ratio, flange, shaft form, swing angle and handwheel or actuator.

Documents and quotation

The manufacturer’s technical data for GS 50.3 is document Y000.289/003/en (issue 1.20) and we can send it with our reply, along with the matching output flange dimension sheet on request. For a quotation, send an RFQ with the part number GS 50.3, the quantity, the reduction ratio, the valve flange, the swing angle, the actuator you plan to mount and the shaft details. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Other Models in the GS Range

Seven Star LLC supplies models from the GS range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
AUMA GS 50.3 Part-Turn Worm Gearbox, 350 Nm, F05-F10Electric ActuatorsYou are viewing this model
AUMA GS 63.3 Part-Turn Worm Gearbox, 700 Nm, F10/F12Electric ActuatorsView details
Datasheets & Documents
  • PDF Datasheet AUMA GS 50.3 Part-Turn Worm Gearbox, 350 Nm, F05-F10 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA GS 50.3 Part-Turn Worm Gearbox, 350 Nm, F05-F10

Answers from our engineering team on installation, compatibility and integration.

01What is the valve torque of AUMA GS 50.3?
The maximum valve torque is 350 Nm and the modulating valve torque is 125 Nm for a swing angle of up to 90 degrees.
02What reduction ratio does GS 50.3 have?
One ratio of 51:1 with a conversion factor of 17.9 and 12.75 input turns for 90 degrees.
03What weight does GS 50.3 have?
7.0 kg including the coupling without bore and the grease filling.
04Which flanges are available on GS 50.3?
F05, F07 and F10 per EN ISO 5211 at the valve side, with F07 (and F10) as the input flange for an actuator.
05Can GS 50.3 be used outdoors?
Yes, the enclosure is IP68 and the standard ambient range is minus 40 to plus 80 degrees C; buried service needs the protection cover option.