Brand: AUMA
AUMA SAEx 16.2 Explosion-Proof Multi-Turn Actuator
Description
Overview
AUMA SAEx 16.2 closes the group IIC part of the SAEx range at sixth place: 400–1,000 Nm (S2-15 min) on an EN ISO 5210 F16 flange with a 500 mm handwheel.
The SAEx 16.2 is supplied across Oman and the GCC by Seven Star LLC, a trusted AUMA supplier, from quotation to start-up advice. Larger projects around Duqm and Sohar can combine it with matching AMExC or ACExC controls in one order. See also: SAEx explosion-proof actuators, SAREx series overview and AUMA TIGRON TR-M explosion-proof multi-turn actuator.
Operating Principle of the AUMA SAEx 16.2
Inside the SAEx 16.2, motor torque passes through a reduction gear to the output drive while mechanical limit and torque switching guard the valve. The 1,000 Nm ceiling holds up to 90 rpm and eases to 800 Nm at 125 and 180 rpm. Self-locking is documented for speeds up to 90 rpm only.
Engineering Design of the SAEx 16.2
The SAEx 16.2 has three weight classes (72, 83 and 88 kg), so confirm the speed ratio before preparing lifting plans. Its 500 mm handwheel is the largest in the 07.2 to 16.2 family and needs clearance on the valve platform. Set the tripping torque with the 1,000 Nm limit in mind, and remember that only speeds up to 90 rpm deliver the full 1,000 Nm.
Electrical connection is made through an AUMA Ex plug/socket connector (KT) with spring-clamp control terminals, within an IP68 enclosure; the optional motor heater is 12.5 W.
Key Features of the AUMA SAEx 16.2
Data points that matter most when specifying the AUMA SAEx 16.2:
- Tripping torque of 400 to 1,000 Nm (S2-15 min) and up to 710 Nm at S2-30 min.
- Permitted run torque begins at 330 Nm and ends at 140 Nm for S2-15 min, depending on speed.
- 60 starts per hour at output speeds of 4–180 rpm (50 Hz).
- A 500 mm handwheel; weight 72 kg (4–22 rpm), 83 kg (32–45 rpm), 88 kg (63–180 rpm).
- Motor ratings of 0.40–6.00 kW (400 V) with 1.4–14 A nominal current.
Selecting the AUMA SAEx 16.2 for Your Valve
The SAEx 16.2 closes the 07.2 to 16.2 family with 1,000 Nm tripping torque, an F16 flange, a 77 mm stem capacity and a 500 mm handwheel. It is the first size where the table splits into three weight classes (72, 83 and 88 kg), so the speed chosen changes the lifting weight. Above 90 rpm the maximum tripping torque falls to 800 Nm, and the run torque falls from 330 Nm at the slowest speeds to 140 Nm at 180 rpm. Valves above 1,000 Nm require the 25.1 frame, which uses a different flange pattern and a different Ex group.
With 400 to 1,000 Nm, an F16 flange and a 77 mm stem, the SAEx 16.2 closes the group IIC range. The step up to the SAEx 25.1 changes the gas group to IIB, the enclosure to IP67 and the starts limit to 40 per hour.
AUMA SAEx 16.2 Torque and Speed Data
AUMA publishes these limits for the AUMA SAEx 16.2 at nominal voltage and +40 °C ambient temperature. Illustrative calculation, not AUMA data: a valve needing 50 turns per stroke takes 273 s at 11 rpm, 48 s at 63 rpm and 17 s at 180 rpm.
| Output speed, rpm | Trip torque, S2-15 / S2-30 min, Nm | Run torque, S2-15 / S2-30 min, Nm |
|---|---|---|
| 4–11 | 1,000 / 710 | 330 / 170 |
| 16–22 | 1,000 / 710 | 300 / 150 |
| 32–45 | 1,000 / 710 | 200 / 100 |
| 63–90 | 1,000 / 710 | 160 / 80 |
| 125 | 800 / 570 | 150 / 75 |
| 180 | 800 / 570 | 140 / 70 |
Worked Sizing Example for the SAEx 16.2 (Illustrative Calculation)
Suppose an export-line block valve requires 780 Nm to seat and 250 Nm to run. The SAEx 16.2 delivers 1,000 Nm at speeds up to 90 rpm, but run torque falls with speed: 330 Nm up to 11 rpm and 160 Nm at 63 to 90 rpm. At 63 rpm the 250 Nm running requirement therefore exceeds the 160 Nm run torque, while at 22 rpm the 300 Nm run torque is adequate. This kind of check is why the speed must be selected together with the torque. This is an illustrative calculation, not AUMA data.
Motor and Electrical Data of the AUMA SAEx 16.2
5 speed points from AUMA’s separate electrical data sheet (S2-15 min, 400 V / 50 Hz), 0.40 to 6.00 kW; approximate values that are not part of the technical datasheet attached here.
| rpm | Motor type | kW | IN, A | Imax, A | IA, A | cos φ |
|---|---|---|---|---|---|---|
| 4 | VDX0112-4-0,40 | 0.40 | 1.4 | 2.7 | 10 | 0.65 |
| 22 | VDX0112-2-1,50 | 1.50 | 5.6 | 11 | 40 | 0.60 |
| 45 | ADX0112-4-3,00 | 3.00 | 8.5 | 17 | 60 | 0.71 |
| 90 | ADX0112-2-5,00 | 5.00 | 12 | 30 | 114 | 0.80 |
| 180 | ADX0112-2-6,00 | 6.00 | 14 | 45 | 114 | 0.83 |
Explosion Protection and Installation Notes for the AUMA SAEx 16.2
Standard ATEX markings of the SAEx 16.2 per AUMA: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db. Certificate: DEKRA 11ATEX0008 X. Confirm temperature class and zone on the nameplate.
The certificate DEKRA 11ATEX0008 X covers all SAEx frames from 07.2 to 16.2, so the group IIC claim applies to this size as listed on the data sheet. Humidity of up to 100 % relative is permitted across the whole temperature range.
Industrial Applications
The AUMA SAEx 16.2 serves large gate valves on pipeline stations, big tank-farm isolation valves and major process block valves where 1,000 Nm is required. The F16 flange and 77 mm stem capacity suit large rising-stem valves, and the valve manufacturer’s torque data always governs sizing.
In Oman’s oil and gas industry such actuators operate pump-station isolation, export-terminal valves and process-train block valves in Zone 1 and Zone 2 areas. Seven Star LLC quotes the SAEx 16.2 as part of full valve-automation packages with Ex-rated controls for projects in Duqm, Sohar and Salalah.
Technical Specifications
Key figures for the AUMA SAEx 16.2, taken from AUMA’s technical data sheet.
| Property | Detail |
|---|---|
| Model | AUMA SAEx 16.2 |
| Torque range S2-15 min | 400–1,000 Nm |
| Output speeds | 4–180 rpm |
| Flange / stem | F16 / 77 mm |
| Handwheel / weight | 500 mm / 72 kg (4–22 rpm), 83 kg (32–45 rpm), 88 kg (63–180 rpm) |
| Gas group | IIC |
| ATEX certificate | DEKRA 11ATEX0008 X |
| Enclosure | IP68 |
| Starts per hour | 60 |
Neighbouring sizes and counterparts: AUMA SAEx 14.6 explosion-proof actuator, AUMA SAEx 25.1 explosion-proof actuator, AUMA SAREx 16.2 explosion-proof modulating actuator and AUMA SA 16.2 multi-turn actuator.
Request a Quote for AUMA SAEx 16.2
Share your valve torque and flange details with Seven Star LLC to receive an offer for the AUMA SAEx 16.2. The AUMA datasheet is available for download below, and lead time is confirmed at quotation.
See also: AUMA SA 16.2 Multi-Turn Actuator.
Datasheets & Documents
- Datasheet AUMA SAEx 07.2 - SAEx 16.2 Technical Data Sheet (open-close duty, 3-phase AC) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SAEx 16.2 Explosion-Proof Multi-Turn Actuator
Answers from our engineering team on installation, compatibility and integration.
01What torque range does the AUMA SAEx 16.2 deliver?
The AUMA SAEx 16.2 has an adjustable tripping torque of 400 to 1,000 Nm for short-time duty S2-15 min and up to 710 Nm for S2-30 min. Run torque depends on output speed and falls from 330 Nm to 140 Nm (S2-15 min) across the speed bands in AUMA's data sheet.
02Which flange, stem size and handwheel does the AUMA SAEx 16.2 use?
The AUMA SAEx 16.2 uses an EN ISO 5210 F16 flange (DIN 3210 option G3), accepts rising stems up to 77 mm and has a 500 mm handwheel. Approximate weight is 72 kg (4–22 rpm), 83 kg (32–45 rpm), 88 kg (63–180 rpm), depending on output speed.
03What explosion protection does the AUMA SAEx 16.2 carry?
AUMA documents these standard ATEX markings for the AUMA SAEx 16.2: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db, with certificate DEKRA 11ATEX0008 X. This covers gas group IIC; confirm temperature class T4 or T3 and the zone on the supplied nameplate and certificate.
04Does the AUMA SAEx 16.2 need separate actuator controls?
Yes. The AUMA SAEx 16.2 is an AUMA NORM actuator and requires electric controls; AUMA offers AMExC and ACExC controls for the SAEx range, which can also be added later. Short-time duty S2-15 min allows up to 60 starts per hour.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so the AUMA SAEx 16.2 is supplied as genuine AUMA product with documentation and regional technical support.