Brand: AUMA
AUMA SA 07.6 Multi-Turn Actuator
Description
Overview
AUMA SA 07.6 is an AUMA NORM multi-turn actuator for open-close duty with a tripping-torque window of 20 to 60 Nm and 12 output speeds from 4 to 180 rpm. SA 07.6 is the 20 to 60 Nm member of AUMA’s compact SA frame group. It doubles the tripping torque of the SA 07.2 while keeping the same F07 and F10 valve interface, the same 160 mm handwheel and almost the same weight, which makes it the natural upgrade where a small valve turns out to be stiffer than first estimated.
Seven Star LLC, a trusted supplier of AUMA products for Oman and the GCC, supplies the AUMA SA 07.6 with manufacturer documentation, and its Muscat team checks the valve and stem data before an order is confirmed.
Operating Principle
On the SA 07.6, a counter gear registers the motor turns between the OPEN and CLOSED end positions, and separate torque switches trip for each direction at up to 60 Nm. Short-time duty S2 – 15 min is standard and S2 – 30 min is optional. The handwheel serves setting and emergency use and stays still during electrical operation.
Engineering Design of the AUMA SA 07.6
Because the housing is IP68 as standard under AUMA’s definition (up to 8 m head of water for 96 hours, with up to 10 operations during immersion), the unit tolerates flooded valve pits and washdown. Specifiers should still choose the stem protection tube and, for coastal sites, confirm KS or KX corrosion protection when placing the order.
Key Features
Points to weigh when specifying the AUMA SA 07.6:
- Compact multi-turn actuator for small gate and globe valves.
- Adjustment range: 20 to 60 Nm per direction, a ratio of 3.0 to 1 between lowest and highest setting.
- Under S2 – 30 min duty the limit is 40 Nm, which is 67 percent of the top tripping value.
- Power density works out at roughly 2.9 to 3.0 Nm of maximum torque per kilogram.
- An illustrative stroke of 15 turns takes about 28.1 seconds at 32 rpm.
- In torque class it ranks above the SA 07.2 and below the SA 10.2.
- Dimension drawings and electrical data are covered by separate AUMA sheets.
Selecting the AUMA SA 07.6
The difference between the SA 07.2 and the SA 07.6 is torque class, not footprint. Both are quoted at 19 to 21 kg and both accept F07 or F10 flanges, so the choice is made purely on the valve data: if the seating or packing torque, plus a healthy margin, stays under 30 Nm the smaller unit is enough, and once it climbs between 30 and 60 Nm the AUMA SA 07.6 is the correct selection. Remember that the tripping torque is adjustable only within the published window, so the 20 Nm minimum of this size also means it should not be fitted to a valve that needs just 8 to 10 Nm.
Typical partners are small gate valves, small globe and stop valves, sample and dosing line isolation valves, and small knife-gate or sluice slides with a rising stem. Through an AUMA part-turn gearbox the same drive can also move small ball, plug or butterfly valves where multi-turn input is required.
A common mistake with small multi-turn actuators is to size on seating torque alone. Packing friction on a gate valve that has been idle through a hot Omani summer can exceed its factory figure by a wide margin, and a valve left closed for months may need a noticeably higher breakaway torque than the data sheet suggests. The 20 to 60 Nm window of the AUMA SA 07.6 gives room to set the closing torque switch above the real value without chasing the limit. Ask the valve maker for the torque at maximum differential pressure, then confirm that the stem thread is lubricated, because a dry stem nut adds friction that the torque switch will read as seat load.
Sizing example for the AUMA SA 07.6
Consider an illustrative gate valve that needs 38 Nm to break away from the seat and 22 Nm to run. Adding a 25 percent margin to the breakaway value gives a setpoint of roughly 48 Nm, comfortably inside the 20 to 60 Nm window of the AUMA SA 07.6, whereas the same valve on a SA 07.2 would be tripping at its 30 Nm ceiling. At 22 rpm a 15-turn stroke takes about 41 seconds, and at 63 rpm the same stroke takes 14 seconds, although the 50 Nm and 30 Nm figures quoted for S2-15 min and S2-30 min at 180 rpm show how torque falls away at the fastest ratio. These numbers are an illustrative calculation and not AUMA data.
Installation and Mounting of the AUMA SA 07.6
With a 20 to 21 kg mass the AUMA SA 07.6 can be lifted by two technicians, so installation does not need a crane. The F07 interface suits valves with a 26 mm stem, while the F10 interface takes up to 34 mm; where the stem rises through the actuator the PMMA protection tube limits the stem to 30 mm. Leave clearance behind the 160 mm handwheel and at the switch compartment cover, because both are removed during commissioning, and point the cable entries downward in outdoor installations.
Industrial Applications
In Oman the AUMA SA 07.6 is most often found on desalination and water-treatment skids, where chemical dosing, antiscalant and permeate lines carry many small isolation valves that must be driven from a control room. It is equally at home on district-cooling plant rooms in Muscat towers, on small fuel-gas and utility-water headers at industrial estates such as Sohar and Rusayl, and on lube-oil and seal-water lines in pump stations where a compact, field-serviceable actuator is wanted.
Related AUMA products from Seven Star LLC include the AUMA SA 07.2 multi-turn actuator, the AUMA SAR 14.1 multi-turn actuator and the AUMA SAREx explosion-proof modulating actuator for small valves across Oman and the GCC.
Neighbouring sizes and counterparts: AUMA SA 07.2 multi-turn actuator, AUMA SA 10.2 multi-turn actuator, AUMA SAR 07.6 modulating actuator and AUMA SAEx 07.6 explosion-proof actuator.
Technical Specifications
Data of the AUMA SA 07.6 from the AUMA technical data sheet for 3-phase AC motors.
| Parameter | Specification |
|---|---|
| Model | AUMA SA 07.6 |
| Torque window, S2 – 15 min | 20 to 60 Nm |
| Ceiling, S2 – 30 min | 40 Nm |
| Derating at fast ratios | 50 Nm (S2-15 min) and 30 Nm (S2-30 min) at 180 rpm only |
| Permitted starts per hour | 60 |
| Speed range | 4 to 180 rpm at 50 Hz, 4.8 to 216 rpm at 60 Hz, 12 steps |
| Flange | EN ISO 5210 F07 and F10; DIN 3210 G0 (option; not offered with F07) |
| Stem capacity | 26 mm (34 mm with the F10 flange; 30 mm maximum when fitted with the PMMA stem protection tube) |
| Handwheel size | 160 mm |
| Mass | 20 to 21 kg |
| Protection class | IP68 |
| Holds position | up to 90 rpm (50 Hz) / 108 rpm (60 Hz) |
Setpoint guide for the SA 07.6 (illustrative calculation, not AUMA data)
| Breakaway torque (Nm) | Setpoint at +25 percent (Nm) |
|---|---|
| 16 | 20 |
| 20 | 25 |
| 25 | 31 |
| 35 | 44 |
| 40 | 50 |
| 48 | 60 |
Stroking time for 15 turns at the SA 07.6 (illustrative calculation, not AUMA data)
| rpm at 50 Hz | rpm at 60 Hz | Seconds for 15 turns at 50 Hz |
|---|---|---|
| 4 | 4.8 | 225 |
| 5.6 | 6.7 | 161 |
| 8 | 9.6 | 113 |
| 11 | 13 | 82 |
| 16 | 19 | 56 |
| 22 | 26 | 41 |
| 32 | 38 | 28 |
| 45 | 54 | 20 |
| 63 | 75 | 14 |
| 90 | 108 | 10 |
| 125 | 150 | 7 |
| 180 | 216 | 5 |
Ordering details for SA 07.6
The SA 07.6 technical data lists the valve mounting arrangement as F07 / F10 (ISO 5210), DIN 3210 G0 option. Record output speed at the site supply frequency, valve travel and required seating torque when selecting the drive.
Request a Quote for AUMA SA 07.6
Tell Seven Star LLC the valve torque, flange (F07 or F10) and stem size, and we will quote the AUMA SA 07.6 within days. The AUMA datasheet is downloadable from this page, and the actuator is delivered as genuine product with warranty.
See also: AUMA SAREx 25.1 Explosion-Proof Modulating Actuator.
Datasheets & Documents
- Datasheet AUMA SA 07.2 - SA 16.2 Technical Data Sheet (covers AUMA SA 07.6) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SA 07.6 Multi-Turn Actuator
Answers from our engineering team on installation, compatibility and integration.
01What is the torque range of the AUMA SA 07.6?
The tripping torque of the AUMA SA 07.6 is adjustable between 20 and 60 Nm in S2 - 15 min duty, and the S2 - 30 min maximum is 40 Nm. Torque is reduced at the highest speeds: 50 Nm (S2-15 min) and 30 Nm (S2-30 min) at 180 rpm only.
02Which output speeds and starts per hour does the AUMA SA 07.6 offer?
The AUMA SA 07.6 offers 12 output speeds from 4 to 180 rpm at 50 Hz and up to 60 starts per hour, and it is self-locking up to 90 rpm (50 Hz) / 108 rpm (60 Hz). An illustrative valve needing 15 turns takes about 28.1 seconds at 32 rpm.
03Which valve flange and stem size does the AUMA SA 07.6 fit?
The AUMA SA 07.6 fits valves with an EN ISO 5210 F07 or F10 flange, accepting a rising stem up to 26 mm on F07 and up to 34 mm on F10 (30 mm if the PMMA stem protection tube is fitted). A DIN 3210 G0 flange is available as an option on the F10 interface.
04When should I choose the AUMA SA 07.6 instead of a neighbouring size?
Choose the AUMA SA 07.6 when the maximum valve torque, including a safety margin, lies between roughly 30 and 60 Nm. Below that range the SA 07.2 is sufficient, and above it the SA 10.2 (40 to 120 Nm) is the next frame size. Send the valve torque table and Seven Star LLC will confirm the selection.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SA 07.6 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.


















Reviews