AUMA SQRV Variable-Speed Modulating Part-Turn Actuator
Description
Overview
The AUMA SQRV adds a new dimension to the proven AUMA SQ/SQR range: variable operating time. Paired with ACV 01.2 actuator controls, the SQRV .2 part-turn actuator for modulating duty can be run at different speeds across the stroke, with AUMA describing an operating time range with a ratio of up to 1:10. For process engineers this removes a long-standing compromise. A fixed-speed actuator has to be sized for a single closing time that suits both normal control and emergency action, whereas the SQRV allows slow, gentle travel for regulation and faster travel when the process demands it. The part-turn actuators of the SQRV .2 range are rated for modulating duty, class C, at S4 – 25 %.
In Oman and the GCC, Seven Star LLC proudly supplies the AUMA SQRV to water authorities, power and desalination operators, and process industries in the Sultanate of Oman and across the GCC. Variable speed is especially valuable on long pipelines and large-diameter butterfly valves in Muscat, Sohar and Salalah, where abrupt valve movement can trigger water hammer. Our team can help you evaluate whether the SQRV with ACV 01.2, or a fixed-speed SQR, is the more economical choice for each valve on your project.
Operating Principle
The AUMA SQRV keeps the familiar SQ .2 mechanical chain of motor, gear stage and splined output shaft, but the motor is driven by the ACV 01.2 controls, which regulate its speed electronically. The operating time for a 90 degree stroke can be set between 4 s and 360 s, and the stroke does not have to be run at one speed. An operating time profile allows the valve to approach its end positions slowly, travel quickly through the mid-range where flow change is small, or slow again where the valve has high control authority. This lets the actuator shape the flow change at the valve instead of simply opening or closing it.
Because the speed is a programmable parameter, the AUMA SQRV can also hold separate behaviour for normal operation and for emergency situations. Emergency behaviour and safety behaviour can be given their own specified operating times, and the response to loss of communication is programmable. A built-in process controller (PID) allows the actuator itself to regulate a process variable, soft start and soft stop reduce mechanical stress on gearing and valve, and operating data logging records how the valve has actually been used. The result is a smoother, quieter pipeline and a longer service life for the valve and its seals.
Engineering Design of the AUMA SQRV
Mechanically the AUMA SQRV follows the SQ .2 design: limit and torque sensing, mains connection in 1-phase and 3-phase versions, a handwheel for manual operation and a mechanical position indicator. The electrical connection uses the AUMA plug/socket connector with terminals as an option, cable entries are available in different versions and valve attachments are made according to DIN and ISO standards. Enclosure protection is IP68, corrosion protection is KS and the ambient temperature range extends from −30 °C to +70 °C.
The interface and functional properties come from the ACV 01.2 controls. They provide programmable potential-free output contacts for status signalling, fieldbus control, a Bluetooth interface to a notebook and Android tablet for commissioning and diagnostics, and operation data logging. Options on the actuator include intermediate position switches, switches in tandem version, a position transmitter and a magnetic limit and torque transmitter. The modulating torque range of 52 Nm to 840 Nm sits within an overall torque range of 150 Nm to 2,400 Nm, which keeps the SQRV firmly in the large butterfly, ball and plug valve segment.
Key Features
The AUMA SQRV is aimed at installations in which smooth, programmable valve movement is as important as torque. Its main features are listed below.
- Operating time for 90 degrees adjustable between 4 s and 360 s, with a ratio of up to 1:10 across the speed range.
- Operating time profile to avoid pressure surge in long or sensitive pipelines.
- Soft start and soft stop for gentle valve operation and lower mechanical stress.
- Separately specified operating times for EMERGENCY behaviour and safety behaviour.
- Integral process controller (PID) for closed-loop regulation at the actuator.
- Fieldbus control with programmable behaviour in case of emergency situations and communication loss.
- Operation data logging and a Bluetooth interface to a notebook and Android tablet for commissioning.
- Programmable potential-free output contacts for status signalling to the control room.
Industrial Applications
The AUMA SQRV is particularly effective where pipeline dynamics, not just valve torque, determine the actuator specification. Long transmission mains, pump station discharge valves and reservoir inlet valves benefit from an operating time profile that limits surge pressures, while district cooling headers and chilled water loops use the PID controller to hold flow or differential pressure without an external regulator. In power and desalination plants, the same variable speed supports fast action when a safety signal arrives and gentle regulation when the plant is running normally, without needing two different actuators.
In Oman and the GCC, Seven Star LLC supplies the AUMA SQRV and the matching ACV 01.2 controls for projects across the Sultanate of Oman and the GCC, including the Sohar and Salalah economic zones and infrastructure works around Muscat. We can assemble the complete package of actuator, controls, fieldbus interface and mounting details so that engineering and procurement teams receive a single, consistent quotation. If the AUMA SQRV is not the closest fit for a valve, see the AUMA SQV variable-speed part-turn actuator, the AUMA SQRVEx or the AUMA SQR for alternatives from the same AUMA family.
Technical Specifications
The following table lists the key data AUMA publishes for the AUMA SQRV .2 type range. Dimensional information for SQV/SQRV 05.2 to 14.2 with ACV 01.2 is available in the linked dimension sheet.
| Parameter | Specification |
|---|---|
| Model | SQRV .2 type range with ACV 01.2 controls |
| Duty type | Modulating duty, class C, S4 – 25 % |
| Torque range | 150 Nm – 2,400 Nm |
| Modulating torque range | 52 Nm – 840 Nm |
| Operating time for 90° | 4 s – 360 s (variable) |
| Swing angle | 75° – 105° |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | −30 °C to +70 °C |
| Mains connection | 1-phase and 3-phase |
| Interfaces | Fieldbus, programmable potential-free contacts, Bluetooth |
| Control functions | PID process controller, soft start/stop, operating time profile |
| Valve attachment | According to DIN and ISO standards |
Request a Quote for AUMA SQRV
To obtain a quotation for the AUMA SQRV with ACV 01.2 controls, please send your valve data, torque requirement, operating time profile and fieldbus preference. Seven Star LLC will return a formal RFQ response with options, availability information and a link to the technical documentation on this page. In Oman and the GCC, we provide the equipment on request and application engineering support from our instrumentation division.
See also: AUMA SQ 12.2 Part-Turn Electric Actuator; AUMA AMExC 01.1 Explosion-Proof Actuator Controls; AUMA SQ 05.2 Part-Turn Electric Actuator.
Datasheets & Documents
- Datasheet AUMA SQV 05.2 - SQRV 14.2 with ACV 01.2 Dimension Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SQRV Variable-Speed Modulating Part-Turn
Answers from our engineering team on installation, compatibility and integration.
01What is the main advantage of the AUMA SQRV over the AUMA SQR?
The SQRV has a variable operating time, from 4 s to 360 s for 90 degrees, with AUMA citing a speed ratio of up to 1:10, together with ACV 01.2 controls. The SQR runs at fixed speed within its 8 s to 100 s range. Variable speed lets you use gentle travel for control and faster travel for emergencies on the same actuator.
02Does the AUMA SQRV help prevent water hammer?
Yes. An operating time profile can slow the stroke where closing causes pressure surge, and soft start and stop reduce mechanical shocks. This is useful on long pipelines and large butterfly valves where abrupt valve movement could cause transients.
03What torque range does the AUMA SQRV cover?
The SQRV .2 range covers 150 Nm to 2,400 Nm, with a modulating torque range of 52 Nm to 840 Nm. It is intended for butterfly, ball and plug valves and carries IP68 enclosure protection and KS corrosion protection.
04How is the AUMA SQRV integrated into a control system?
The ACV 01.2 controls offer fieldbus control with programmable behaviour for emergencies and communication loss, programmable potential-free output contacts, a PID process controller, operation data logging and a Bluetooth interface for commissioning from a notebook or Android tablet.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies AUMA products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.


















Reviews
There are no reviews yet.