Brand:

Honeywell SPXCDALMTX4 Sensepoint XCD RTD Transmitter

Description

Honeywell SPXCDALMTX4 is the Sensepoint XCD RTD, the remote toxic detector transmitter. It is a transmitter without a sensor: you order it in an ATEX and IECEx certified LM25 aluminium enclosure, then order the Sensepoint toxic or oxygen sensor separately. The idea behind the RTD is that the display, relays and 4 to 20 mA output sit in a place that people can reach and read, while the sensor goes where the gas is, up to 30 metres or 100 feet away from the transmitter in a hard-to-access area.

Order code and supply of SPXCDALMTX4

The code is SPXCD for the Sensepoint XCD range, A for ATEX and IECEx certification, L for LM25 aluminium, M for two M20 side entries plus an M25 bottom entry, and TX4 identifying the RTD transmitter version. Honeywell supplies the unit with an integral wall mounting plate, two M20 side entries and one M25 bottom entry, one M20 plug, an Allen key for the locking screw, an operating magnet, a quick start guide and a manual on CD. Default settings are tested at the factory and each unit has a test certificate.

SPXCDALMTX4 specifications

Parameter Value
Function 3-wire 4 to 20 mA transmitter for Sensepoint toxic and oxygen sensors
Supply 18 to 32 VDC, 24 VDC nominal; maximum 5 W
Output 4 to 20 mA, sink or source; 22.0 mA over range; below 1.0 mA fault; 2.0 or 4.0 mA inhibit
Relays 3 x 5 A at 250 VAC, programmable
Terminals 18 screw terminals, 0.5 to 2.5 mm squared
Housing Epoxy-painted aluminium alloy LM25, approx. 2.0 kg; sensor mass up to 0.2 kg
Entries 2 x M20 side, 1 x M25 bottom
Ingress protection Transmitter IP66; Sensepoint sensor IP67
Certified temperature -40 to +65 degrees C (display may be illegible below -20 degrees C but still measures)
Humidity 20 to 90 percent RH continuous, up to 99 percent intermittent, non-condensing
Certification ATEX II 2 GD Ex d IIC Gb T6, Ex tb IIIC T85 degrees C Db IP66; IECEx; GB; KTL
Shipping 312 x 223 x 110 mm, approx. 2.5 kg aluminium

Sensors that connect to SPXCDALMTX4

The SPXCDALMTX4 works with the Sensepoint toxic and oxygen heads listed in the datasheet: H2S in 20, 50 and 100 ppm spans (2106B1400 to 2106B1402 with M20 thread, 2106B1500 to 1502 with M25), CO in 100, 200 and 500 ppm, Cl2 in 5 and 15 ppm, NH3 in 50, 100 and 1000 ppm, SO2 in 15 and 50 ppm, NO2 at 10 ppm, NO at 100 ppm and O2 at 25 percent by volume. Because the RTD bottom entry is M25, the M25 sensor versions plug directly. Default alarms follow the gas: for 20 ppm H2S they are 4 ppm and 8 ppm, and oxygen alarms at 19.5 percent falling and 23.5 percent rising.

How SPXCDALMTX4 differs from other transmitter versions

The sister item SPXCDASMTX4 is identical in electronics but in 316 stainless steel, at about 5.5 kg shipping weight. The SPXCDALMRFD and SPXCDASMRFD transmitters are for flammable sensors, with a different personality and input, and the full XCD detectors of the SPXCDALM family integrate the sensor into the transmitter. The RTD is the one to choose when the sensor must be remote or when you want to reuse existing Sensepoint heads.

Typical applications and installation

Heads can be mounted on the M25 bottom entry or on a certified junction box or duct mounting assembly. Wire the sensor on a two-wire 4 to 20 mA connection at the sensor terminals, with +24 VDC on the red wire and the 4 to 20 mA signal on the blue wire. Honeywell’s cable chart for the RTD, with a minimum detector voltage of 18 VDC, lists 353 metres for 0.5 mm squared cable. The tri-colour LCD is visible from a distance and a user can configure range, alarms and tag number with the magnet.

Commissioning and spares

The SPXCDALMTX4 inhibits its outputs during adjustment to prevent false alarms at the control panel. When fitting a Sensepoint sensor, calibrate with a calibration cup S3KCAL. Optional accessories include the pipe mounting bracket SPXCDMTBR, the sunshade SPXCDSDP and the weather proof cap SPXCDWP. Sensor cell exchange kits for O2, SO2, Cl2, CO, H2S, NO, NH3, H2 and NO2 are listed as 2106B1545 to 2106B1599.

The remote option deserves a short explanation, because it is the main reason to buy the SPXCDALMTX4 rather than a complete XCD detector. A sensor in a pit, on a high structure or inside a duct is difficult to reach for calibration, and a display that nobody can read is of little use. With the RTD the transmitter is fixed at a convenient height, with its tri-colour backlight visible from across the area, while a short two-conductor run carries the sensor signal. The sensor terminals on the RTD are 16 for the 24 VDC supply, red wire, and 17 for the 4 to 20 mA signal, blue wire, which are the same conductors used when the head is connected to any other controller.

Mechanically, the transmitter uses the same body as other XCD products, so existing brackets, sunshades and weather caps fit. The housing is epoxy-painted aluminium alloy LM25 and the toxic sensor body is polyphenylene sulphide, with a plastic weather protection assembly. Entries are two M20 on the sides and one M25 at the bottom, with a blanking plug supplied for an unused side entry, to be sealed to retain IP66. Honeywell gives shipping dimensions of 312 by 223 by 110 millimetres, and a stainless steel unit of about 5.5 kg shipping weight. For toxic gas detection where several different gases are monitored in one plant, a common RTD transmitter reduces the number of spare parts and training needs because every gas uses the same interface.

Ordering notes for SPXCDALMTX4

State the sensor gas, range and thread when requesting a quotation for SPXCDALMTX4, since the transmitter does not include any sensor. Modbus RTU is described in the RTD datasheet as optional or pending, so confirm availability before specifying it.

Documents and quotation

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We can attach the XCD RTD datasheet to our quotation. Send an RFQ with SPXCDALMTX4, the quantity, the sensor part numbers and the delivery location.

Datasheets & Documents
  • PDF Datasheet Sensepoint XCD RTD Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell SPXCDALMTX4 Sensepoint XCD RTD Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What does Honeywell SPXCDALMTX4 do?
It is the Sensepoint XCD RTD transmitter in an LM25 aluminium housing, used with separately ordered Sensepoint toxic or oxygen sensors that can be mounted up to 30 metres away.
02Does SPXCDALMTX4 include a gas sensor?
No. Honeywell notes that the required sensor must be ordered separately, so you must also specify the gas, range and M25 or M20 thread of the head.
03What supply does SPXCDALMTX4 need?
The datasheet lists 18 to 32 VDC with 24 VDC nominal and a maximum power consumption of 5 W.
04How many relays are provided by SPXCDALMTX4?
Three programmable relays rated 5 A at 250 VAC, defaulting to two alarm relays and one fault relay.
05What is the stainless steel equivalent of SPXCDALMTX4?
SPXCDASMTX4 is the 316 stainless steel version with the same electronics, with a shipping weight of about 5.5 kg compared with 2.5 kg for aluminium.