Description

Overview

The Dräger Flame 1500 (IR3) flame detector uses its triple IR sensor to detect hydrocarbon fires even at great distances, providing excellent false alarm immunity as approved by FM while maintaining a response time of under 4 seconds. The Flame 1500 is equipped with three infrared sensors that enable it to detect hydrocarbon-based fires even at a great distance, with this reliability allowing it to meet IEC 61508 requirements for safety integrity according to SIL2.

As a trusted supplier of Dräger safety equipment, Seven Star LLC proudly offers the Flame 1500 to oil and gas, petrochemical, and offshore facilities across the Sultanate of Oman, Muscat, and the wider GCC. The flame detector also features a HART interface via which it can be connected directly to a fire alarm system, alongside notably low power consumption.

Measurement Principle

The Flame 1500 measures infrared radiation across three different wavelengths (in the 3μm to 8μm range) and compares them with the reference value of CO2, which is produced during the combustion of hydrocarbons. In combination with analysis of the flame’s flickering pattern, a complex algorithm identifies a genuine fire event and excludes common sources of false-alarm interference such as sunlight, welding arcs, and lightning.

The detector achieves detection ranges of 50m (165 ft) for methane fires, 42m (136 ft) for methanol fires, and up to 60m (200 ft) for n-heptane/gasoline fires, with a horizontal and vertical field of view of 90° each. Sensitivity settings of High (60m), Medium (30m, standard), and Low (15m) allow the detector to be tuned to the specific hazard profile and desired coverage area of an installation.

Engineering Design of the Flame 1500

The Flame 1500 is available in powder-coated aluminium (2.5kg/5.5 lbs) or stainless steel (6kg/13.2 lbs) construction with dual M25 cable glands, operating from an 18 to 32VDC supply (24VDC nominal) with a maximum power consumption of 12W with heating enabled (minimum 3W). The detector carries IP66 ingress protection and NEMA 4X classification, with an extreme operating temperature range of -60°C to +85°C (-76°F to +185°F) suitable for both arctic and desert deployments.

Output is provided via a 0 to 20mA analog signal with alarm and fault relay outputs, alongside HART 7 and RS485 digital communication for direct integration with fire alarm and control systems. An Optical Verification Test (OVT) automatically checks the detector’s electronics and optics without obstructing the field of view, while a tri-color front LED indicates device status: green for normal operation, yellow for fault, and red for fire alarm.

Key Features

The Flame 1500 combines triple-IR sensing with rugged, hazardous-area-rated construction. Core capabilities include:

  • Triple infrared (IR3) sensors for reliable hydrocarbon fire detection at long range.
  • SIL2 safety integrity per IEC 61508, with excellent FM-approved false alarm immunity.
  • Response time of less than 4 seconds (typical).
  • Detection range up to 60m (200 ft) for n-heptane/gasoline fires.
  • HART 7 and RS485 digital communication for direct fire alarm system integration.
  • Extreme operating temperature range of -60°C to +85°C.
  • Optical Verification Test (OVT) for automatic electronics and optics self-check.
  • ATEX, FM/FMC, and IECEx hazardous area approvals for worldwide application.

Industrial Applications

The Flame 1500 is well suited to offshore platforms, refineries, and petrochemical plants across Oman requiring reliable, long-range detection of hydrocarbon fires with minimal false alarms. Its extreme temperature rating and robust aluminium or stainless steel housing make it dependable for both onshore desert installations and harsh offshore marine environments throughout the region.

As a trusted supplier of Dräger safety equipment, Seven Star LLC supports oil and gas facilities, chemical plants, and marine installations throughout the Sohar and Salalah economic zones and the broader GCC region with the Flame 1500’s proven triple-IR flame detection platform.

Technical Specifications

Full technical parameters for the Dräger Flame 1500 (IR3) flame detector:

Parameter Specification
Model Flame 1500 (IR3)
Detector Type Explosion-Proof Triple-Spectrum IR
Wavelength Range 3μm to 8μm (3 Wavelengths)
Response Time < 4 Seconds (Typical)
Detection Range Up to 60m (200 ft), n-Heptane/Gasoline
Field of View Horizontal 90°, Vertical 90°
Power Supply 18 to 32 VDC (24 VDC Nominal)
Output 0-20mA, Alarm/Fault Relays, HART 7, RS485
Housing Material Aluminium or Stainless Steel
Ingress Protection IP66, NEMA 4X
Operating Temperature -60°C to +85°C
Safety Rating SIL2 (IEC 61508)
Hazardous Area Approvals ATEX, FM/FMC, IECEx

Why Choose Seven Star LLC for Flame Detection Coverage Planning

A flame detector’s real-world detection range depends heavily on the target fuel type and the sensitivity setting selected – the Flame 1500’s rated 60m range for n-heptane fires does not automatically apply to a methane or methanol hazard, and specifying coverage without accounting for that difference leaves gaps in a facility’s fire detection layout. Seven Star LLC’s engineers review the specific hydrocarbon hazards and vessel/process layout with the customer before quoting, confirming detector placement, field-of-view overlap, and sensitivity setting against the actual fuel types present rather than a generic default. We also help plan spare-unit stock for safety-critical fire detection loops and coordinate delivery around planned turnarounds at offshore and onshore facilities across Oman, since a gap in flame coverage during a shutdown is not an acceptable risk.

Request a Quote for Dräger Flame 1500 (IR3) Flame Detector

To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the Dräger Flame 1500 (IR3) Flame Detector, please contact Seven Star LLC today. As a trusted supplier of Dräger safety equipment in Oman and the GCC, our engineers are ready to assist with rapid sourcing for your fire and flame detection projects.

Related Products

Datasheets & Documents
  • PDF Datasheet Dräger Flame 1500 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Drägerwerk is a German maker of safety and medical technology, founded in Lübeck on 1 January 1889 as Dräger & Gerling by Johann Heinrich Dräger and Carl Adolf Gerling. Its first patent was the Lubeca valve, a pressure reducer for carbon dioxide. Drägerwerk AG is listed on the stock exchange but still controlled by the founding family, led by fifth-generation chairman Stefan Dräger.

Seven Star LLC sources and supplies Dräger fixed gas transmitters, flame detectors, portable gas detectors and Dräger-Tubes for sites in Oman, and checks each part number against the manufacturer's documentation.

Dräger company profile

Founded 1 January 1889, Lübeck, Germany, as Dräger & Gerling
Founders Johann Heinrich Dräger and Carl Adolf Gerling
Headquarters Lübeck, Germany
Ownership Drägerwerk AG & Co. KGaA, listed in Frankfurt; controlled by the Dräger family
Product families Polytron fixed gas detectors, flame detectors, X-am and Pac portable gas detectors, Dräger-Tubes, breathing apparatus, gas detection controllers; anaesthesia, ventilation and patient monitoring in the medical division

Milestones

  • 1889: Dräger & Gerling is founded in Lübeck; the Lubeca valve is its first patent.
  • 1902: Bernhard Dräger joins and the company becomes Drägerwerk Heinr. und Bernh. Dräger.
  • 1907: The Pulmotor resuscitator goes into series production.
  • 1970: Drägerwerk becomes an Aktiengesellschaft.

Dräger gas detection product families listed here

Fixed detection is covered by the Polytron line: the Polytron 8100 EC for toxic gases and oxygen with electrochemical sensors, the Polytron 8200 CAT for flammable gases with a catalytic sensor, the Polytron 7000 and the PIR 7000 point infrared detector for hydrocarbons. Dräger flame detectors on this page are the Flame 1500 and Flame 2500 (triple infrared) and the Flame 2700 (multi-infrared). Portable instruments include the Pac 8000 single-gas detector, the X-am 2500 for one to four gases and the X-am 8000 for up to seven. Short-term colorimetric tubes such as Hydrogen Sulfide 100/a (CH29101) are listed with the analyzer accessories.

Where Dräger detectors are used

Polytron transmitters and PIR 7000 heads are found on wellhead and gathering facilities, gas plants, refineries, tank farms, LNG and petrochemical units, and in water treatment chlorine rooms. Portable Dräger gas detectors serve confined space entry, hot work permits and personal H2S monitoring, which is routine on sour fields in the GCC. Detector tubes remain a simple spot check where an electronic sensor is not available for the gas.

Dräger products we list

Family Examples
Fire & Gas Detectors Flame 1500 (IR3) Flame Detector, Flame 2500 (IR3) Flame Detector, Flame 2700 (Multi-IR) Flame Detector, Pac 8000 Single-Gas Detector, PIR 7000 Point Infrared Gas Detector, Polytron 7000 Gas Detector, Polytron 8100 EC Toxic Gas Transmitter, Polytron 8200 CAT Flammable Gas Transmit… and 2 more
Gas Analyzer Accessories 8101211, Gastec No.4HH Hydrogen Sulphide H2S Dete…, Tube: Hydrogen Sulfide 100/a (CH29101)

Ordering Dräger equipment: what we need

Dräger identifies most items by a seven-digit part number, such as 8101211, and that number is the most direct route to the right quotation. For a fixed transmitter, add the target gas, measuring range, output (4-20 mA, HART or relays), housing material, cable entry thread and the required hazardous-area approval. For portables, list the sensor configuration, pump or diffusion mode and the charger or calibration accessories needed. For tubes, give the gas and the range printed on the box.

Facts checked against Dräger's own history pages (draeger.com) and published company histories, October 2026.

FAQ

Questions about the Dräger Flame 1500 (IR3) Flame Detector

Answers from our engineering team on installation, compatibility and integration.

01How far can the Flame 1500 detect fires?
Detection range varies by fuel type: up to 50m for methane, 42m for methanol, and up to 60m for n-heptane/gasoline fires, with a 90u00b0 horizontal and vertical field of view.
02How does the Flame 1500 avoid false alarms?
It measures infrared radiation across three wavelengths and compares them against the CO2 reference produced during hydrocarbon combustion, combined with flame flicker analysis to exclude interference sources.
03Is the Flame 1500 SIL rated?
Yes. Its reliability allows it to meet IEC 61508 requirements for safety integrity according to SIL2.
04What is the operating temperature range of the Flame 1500?
It operates across an extreme range of -60u00b0C to +85u00b0C, suitable for both desert and arctic deployments.
05Is Seven Star LLC a trusted supplier for Dru00e4ger products?
Yes. Seven Star LLC is an experienced supplier of Dru00e4ger safety equipment in Oman and the GCC, providing genuine products with full support.