The Drager X-am 8000 is a versatile portable multi-gas detector capable of simultaneously monitoring up to seven gases, covering toxic gases, combustible gases, volatile organic compounds, and oxygen in a single compact instrument. Equipped with five sensor slots and compatible with over 40 different DragerSensor variants – including catalytic bead, electrochemical, infrared, and photoionization detector (PID) technologies – the X-am 8000 gives safety managers a flexible platform that can be configured precisely to the hazards present at a given worksite.

For oil and gas, petrochemical, and industrial facilities across Oman and the wider GCC, the X-am 8000 supports confined space entry, personal air monitoring, and area monitoring applications where worker safety depends on immediate, reliable gas detection. Seven Star LLC supplies the Drager X-am 8000 multi-gas detector to customers across Muscat, Sohar, Salalah, and the Sultanate of Oman as a supplier of Drager products, providing instruments with full documentation and technical support.

Measurement and Operating Principle

The X-am 8000 can operate in either diffusion mode, where ambient air passively reaches the sensors, or pump mode, where an internal high-performance pump actively draws a sample through hoses up to 45 meters in length – essential for clearance measurements in tanks, vessels, and confined spaces before personnel entry. A pump adapter allows technicians to switch between the two modes as needed, activating the pump only when required to save energy, reduce wear, and extend service life.

DragerSensor technology across the CatEx (catalytic bead), electrochemical, infrared, and PID sensor families provides fast response times and long sensor life, with the device’s on-board library and assistant functions allowing unused sensor channels to be hidden and measurement gases switched during operation for PID, CatEx, and IR sensors. This flexibility lets a single X-am 8000 unit be reconfigured for different monitoring tasks without requiring a separate instrument for each gas hazard scenario.

Engineering Design of the Drager X-am 8000

Built for one-handed operation with three simple function keys and an easy-to-read full-color display, the X-am 8000 is compact and rugged, rated to IP68 for reliable performance in demanding field conditions. The instrument uses inductive charging, eliminating the corrosion and contact wear associated with traditional charging contacts, and allows charging and measurement to occur simultaneously outside explosion-hazard zones, such as when mounted in a vehicle or on machinery between uses.

The X-am 8000’s alarm system follows a standardized color-coded signaling design compliant with EN 60079-29-1, EN 45544-1, and EN 50104: a red light indicates a gas alarm, yellow indicates a device-related warning such as low battery, and green confirms the device is operational and ready for use. When an alarm triggers, the instrument alerts the wearer with bright multi-colored LEDs, a loud 100 dB(A) horn at 30 cm, and strong vibration, ensuring the alarm is noticed even in high-noise industrial environments. Built-in impact detection logs mechanical shocks to the event log and data logger, flagging the device for inspection, with an option to automatically lock the unit following an impact until it has been checked.

Key Features

  • 1 to 7 simultaneous gas measurement across 5 sensor slots
  • Compatible with over 40 DragerSensor variants (CatEx, EC, IR, PID)
  • Diffusion or pump mode with hoses up to 45 m for clearance measurement
  • IP68-rated rugged housing for demanding field conditions
  • Inductive charging for reduced wear and simultaneous charge/measure
  • Color-coded alarm signaling per EN 60079-29-1, EN 45544-1, EN 50104
  • Built-in impact detection with event logging
  • Detects up to 127 substances including VOCs, TICs, and combustible gases

Industrial Applications

The X-am 8000 is widely used for confined space entry clearance measurements, personal air monitoring for workers in hazardous atmospheres, and fixed or portable area monitoring around process equipment, tank farms, and maintenance work zones. Its PID sensor options, including a low-concentration PID for detection below 1 ppm, make it particularly well suited to benzene-specific and other aromatic hydrocarbon monitoring tasks common in oil and gas and petrochemical facilities.

Across Oman’s oil, gas, and industrial sectors, including facilities supporting the Sohar and Salalah economic zones, the X-am 8000 gives safety teams a single, reconfigurable multi-gas detection platform for a wide range of workplace hazard scenarios. As a trusted supplier of Drager products, Seven Star LLC supports these projects throughout the Sultanate of Oman with detectors, sensor configuration guidance, and technical support.

Technical Specifications

Model Drager X-am 8000
Type Portable multi-gas detector
Gas Capacity 1 to 7 gases across 5 sensor slots
Sensor Technologies CatEx, electrochemical (EC), infrared (IR), PID
Operating Modes Diffusion or pump (hoses up to 45 m)
Protection Rating IP68
Alarm Signaling Color-coded LED, 100 dB(A) horn, vibration
Battery Li-Ion, inductive charging
Manufacturer Drager

Why Choose Seven Star LLC for Drager Multi-Gas Detectors

A multi-gas detector’s real protection depends on the specific sensor combination (O2, LEL, CO, H2S, or specialty sensors) matching the actual hazards present at your work site, since a detector configured for the wrong gas set gives workers false confidence while missing the real threat. Seven Star LLC confirms the correct X-am 8000 sensor configuration against your site’s hazard assessment before order confirmation, backed by our trusted Drager suppliership across Oman and the wider GCC. We also support oil, gas, and industrial safety teams across Muscat, Sohar, and Salalah with bump-testing and calibration scheduling, so portable gas detection fleets remain reliably field-ready for confined-space entry and hot-work permits.

Order Your Drager X-am 8000 Today

Contact Seven Star LLC to request a quotation, datasheet, or technical consultation for the Drager X-am 8000 multi-gas detector. As a trusted Drager supplier serving Muscat, Sohar, Salalah, and the greater Sultanate of Oman, Seven Star LLC supplies instrumentation with full documentation and dedicated technical support for gas detection projects across the GCC.

Related Products

Datasheets & Documents
  • PDF Datasheet Dräger X-am 8000 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Drägerwerk is a German maker of safety and medical technology, founded in Lübeck on 1 January 1889 as Dräger & Gerling by Johann Heinrich Dräger and Carl Adolf Gerling. Its first patent was the Lubeca valve, a pressure reducer for carbon dioxide. Drägerwerk AG is listed on the stock exchange but still controlled by the founding family, led by fifth-generation chairman Stefan Dräger.

Seven Star LLC sources and supplies Dräger fixed gas transmitters, flame detectors, portable gas detectors and Dräger-Tubes for sites in Oman, and checks each part number against the manufacturer's documentation.

Dräger company profile

Founded 1 January 1889, Lübeck, Germany, as Dräger & Gerling
Founders Johann Heinrich Dräger and Carl Adolf Gerling
Headquarters Lübeck, Germany
Ownership Drägerwerk AG & Co. KGaA, listed in Frankfurt; controlled by the Dräger family
Product families Polytron fixed gas detectors, flame detectors, X-am and Pac portable gas detectors, Dräger-Tubes, breathing apparatus, gas detection controllers; anaesthesia, ventilation and patient monitoring in the medical division

Milestones

  • 1889: Dräger & Gerling is founded in Lübeck; the Lubeca valve is its first patent.
  • 1902: Bernhard Dräger joins and the company becomes Drägerwerk Heinr. und Bernh. Dräger.
  • 1907: The Pulmotor resuscitator goes into series production.
  • 1970: Drägerwerk becomes an Aktiengesellschaft.

Dräger gas detection product families listed here

Fixed detection is covered by the Polytron line: the Polytron 8100 EC for toxic gases and oxygen with electrochemical sensors, the Polytron 8200 CAT for flammable gases with a catalytic sensor, the Polytron 7000 and the PIR 7000 point infrared detector for hydrocarbons. Dräger flame detectors on this page are the Flame 1500 and Flame 2500 (triple infrared) and the Flame 2700 (multi-infrared). Portable instruments include the Pac 8000 single-gas detector, the X-am 2500 for one to four gases and the X-am 8000 for up to seven. Short-term colorimetric tubes such as Hydrogen Sulfide 100/a (CH29101) are listed with the analyzer accessories.

Where Dräger detectors are used

Polytron transmitters and PIR 7000 heads are found on wellhead and gathering facilities, gas plants, refineries, tank farms, LNG and petrochemical units, and in water treatment chlorine rooms. Portable Dräger gas detectors serve confined space entry, hot work permits and personal H2S monitoring, which is routine on sour fields in the GCC. Detector tubes remain a simple spot check where an electronic sensor is not available for the gas.

Dräger products we list

Family Examples
Fire & Gas Detectors Flame 1500 (IR3) Flame Detector, Flame 2500 (IR3) Flame Detector, Flame 2700 (Multi-IR) Flame Detector, Pac 8000 Single-Gas Detector, PIR 7000 Point Infrared Gas Detector, Polytron 7000 Gas Detector, Polytron 8100 EC Toxic Gas Transmitter, Polytron 8200 CAT Flammable Gas Transmit… and 2 more
Gas Analyzer Accessories 8101211, Gastec No.4HH Hydrogen Sulphide H2S Dete…, Tube: Hydrogen Sulfide 100/a (CH29101)

Ordering Dräger equipment: what we need

Dräger identifies most items by a seven-digit part number, such as 8101211, and that number is the most direct route to the right quotation. For a fixed transmitter, add the target gas, measuring range, output (4-20 mA, HART or relays), housing material, cable entry thread and the required hazardous-area approval. For portables, list the sensor configuration, pump or diffusion mode and the charger or calibration accessories needed. For tubes, give the gas and the range printed on the box.

Facts checked against Dräger's own history pages (draeger.com) and published company histories, October 2026.

FAQ

Questions about the Drager X-am 8000 Multi-Gas Detector

Answers from our engineering team on installation, compatibility and integration.

01How many gases can the X-am 8000 detect simultaneously?
The X-am 8000 has five sensor slots and can detect 1 to 7 gases simultaneously depending on the configured sensors.
02What is the difference between pump and diffusion mode?
In diffusion mode, ambient air passively reaches the sensors, while in pump mode an internal pump actively draws a sample through hoses up to 45 m, used for clearance measurements before confined space entry.
03What sensor technologies does the X-am 8000 support?
The X-am 8000 supports catalytic bead (CatEx), electrochemical (EC), infrared (IR), and photoionization detector (PID) sensors, with compatibility for over 40 DragerSensor variants.
04How does the X-am 8000 alert users to a gas alarm?
The device uses color-coded LEDs (red for alarm, yellow for warning, green for ready), a 100 dB(A) horn at 30 cm, and strong vibration to alert users.
05Is Seven Star LLC a trusted Drager supplier in Oman?
Yes. Seven Star LLC is a trusted Drager distribution supplier supplying gas detection instrumentation across Muscat, Sohar, Salalah, and the wider Sultanate of Oman.