Brand: LAMTEC
Lamtec FFS08 Flame Sensor for Burner Flame Monitoring
Description
Overview
The Lamtec FFS08 is a non-compact flame sensor designed for safety-critical flame monitoring on industrial burners, mounted orthogonally to the flame axis for flexible installation on a wide range of firing systems. Available in ultraviolet (UV) and infrared (IR) spectral variants, the FFS08 detects the optical radiation emitted by a stable flame and passes this signal to the LAMTEC F152 evaluation unit or a compatible burner management system such as the CMS or ETAMATIC, which continuously verifies flame presence and initiates burner shutdown if the flame signal is lost.
Seven Star LLC supplies the Lamtec FFS08 as an experienced supply partner of Lamtec, supporting combustion safety and burner management upgrades for power plants, process heaters, and industrial boiler installations across Muscat, Sohar, Salalah, and the wider Sultanate of Oman. Genuine Lamtec flame sensors, evaluation units, and burner management components are available through Seven Star LLC for new-build and retrofit combustion safety projects throughout the GCC.
Measurement and Operating Principle
The FFS08 uses optical radiation detection to continuously verify that a burner flame is present and stable. UV-sensitive variants respond to the ultraviolet radiation characteristic of open flames from natural gas and light fuel oil, while IR-sensitive variants respond to infrared radiation and flicker frequency, suited to fuels and flame types where UV signal strength is weaker. The sensor’s optical signal is transmitted to the F152 evaluation unit, which analyzes signal strength and flicker characteristics against SIL 3 safety logic to distinguish a genuine flame from background radiation, hot refractory glow, or other false-positive sources.
Because the FFS08 operates in continuous mode, it is suited to applications requiring ongoing flame supervision throughout the burner firing cycle, rather than intermittent pilot-only monitoring. The evaluation unit’s SIL 3 safety rating, certified to DIN EN 61508 and DIN EN 298, ensures that a genuine loss-of-flame condition results in a rapid, fail-safe burner trip, protecting against unburned fuel accumulation and potential explosion hazards in the furnace or combustion chamber.
Each FFS08 variant is tuned to a specific optical acceptance angle to match the flame geometry it must reliably see: approximately 8° for the UV variant and a wider 60° field of view for the IR variants, letting the specifying engineer match sensor selectivity to burner design and furnace geometry. Minimum usable signal output is specified at greater than 25 mVAC for UV variants and greater than 10 mVAC for IR variants, with a minimum flicker frequency of approximately 7 Hz used by the F152 evaluation unit to help distinguish a genuine modulating flame from steady background radiation. The sensor draws 24 to 42 VDC at no more than 20 mA and connects via a shielded six-conductor cable (6 x 0.34/0.5 mm²) that can run up to 300 meters to the evaluation unit, supporting flame sensors mounted well away from the control room on large boiler fronts.
Engineering Design of the Lamtec FFS08
The FFS08 is housed in a robust nickel-plated brass (EN CW614N) cylindrical body with a threaded optical viewing window at the sensing end and a cable gland connection at the mounting end, built to withstand the vibration, heat, and dust conditions typical of burner fronts in industrial boiler and process heater installations. The sensor is approved for safe-area use and is available in multiple spectral configurations (UV-4, IR-1, IR-1 T, IR-1 T/S2) to match the flame characteristics of natural gas, light fuel oil, and other single- or multi-fuel combustion applications.
Mounting accessories, including the FS60-00 and FS60-10 brackets and the FS65 cooling air housing, allow the FFS08 to be positioned at the optimal viewing angle relative to the flame while protecting the sensor from excessive furnace radiant heat. The FFS08 pairs with LAMTEC’s F152 evaluation unit for standalone flame monitoring installations, or integrates directly with LAMTEC’s CMS combustion management system and ETAMATIC burner controls for fully integrated combustion safety and control architectures, simplifying wiring and commissioning on new burner management system projects.
The standard Lamtec FFS08 weighs approximately 0.40 kg complete with its 3 m connection cable and reaches a maximum immersion depth of 65 mm into the burner front. The longer L variant weighs approximately 0.55 kg and extends to a 150 mm immersion depth for recessed or refractory-lined mounting positions; both configurations are rated IP66/IP67. In addition to the F152 evaluation unit, CMS and ETAMATIC systems already referenced, the sensor is also compatible with LAMTEC’s MCC BC400 burner control, broadening the range of combustion management architectures it can be specified into without changing the sensor itself.
Key Features
- Non-compact flame sensor for continuous flame monitoring on single and multi-fuel burners
- Available in UV and IR spectral variants (UV-4, IR-1, IR-1 T, IR-1 T/S2)
- SIL 3 safety rating in combination with F152 evaluation unit, per DIN EN 61508
- EC Type Examination Certified to DIN EN 298 and the EU Pressure Equipment Directive
- Compatible with LAMTEC F152 evaluation unit, CMS, and ETAMATIC burner controls
- Robust nickel-plated brass (EN CW614N) housing suited to industrial burner-front conditions
- Operating temperature range −20°C to +65°C (UV) / +60°C (IR)
- UL 60730-2-5 listed and IACS ship certification available for marine applications
Industrial Applications
The FFS08 is specified for flame safety monitoring on heating plant boilers, process combustion systems, hydrogen-fired plants, and natural gas and light fuel oil burners across power generation, refining, petrochemical, and district heating facilities. Its continuous-operation design and SIL 3 safety integration make it a critical safety component wherever unsupervised loss of flame could result in unburned fuel accumulation and explosion risk.
Across Oman’s power generation and process industries, from combined-cycle plants to industrial boiler houses in Sohar and Salalah, Seven Star LLC supports engineering, procurement, and maintenance teams specifying the FFS08 as part of new or upgraded burner management systems. As a trusted supplier of Lamtec products, Seven Star LLC provides genuine flame sensors, evaluation units, and mounting accessories with full commissioning and technical support across Muscat and the wider GCC.
Technical Specifications
| Model | Lamtec FFS08 |
|---|---|
| Type | Non-compact flame sensor, orthogonal mounting to flame axis |
| Sensor Variants | UV-4, IR-1, IR-1 T, IR-1 T/S2 |
| Operating Mode | Continuous operation |
| Safety Integrity Level | SIL 3 (with F152 evaluation unit), per DIN EN 61508-2 |
| Degree of Protection | IP67 (safe area, standard); Ex zone 1/2 variants via FFS07 |
| Operating Temperature | −20°C to +65°C (UV); −20°C to +60°C (IR) |
| Evaluation Device | LAMTEC F152; also compatible with CMS and ETAMATIC burner controls |
| Approvals | DIN EN 298, DIN EN 61508, EU PED 2014/68/EU, CE, UL 60730-2-5, IACS UR E10 |
| Typical Fuels | Natural gas, light fuel oil (LFO), hydrogen, multi-fuel systems |
| Accessories | FS60-00/FS60-10 brackets, FS65 cooling air housing, FFP30 test device |
| Viewing Angle | UV ~8°; IR ~60° |
| Signal Output | >25 mVAC (UV); >10 mVAC (IR); min. flicker freq. ~7 Hz |
| Power Consumption | 24–42 VDC, ≤20 mA |
| Cable | Shielded, 6 x 0.34/0.5 mm²; max. run 300 m |
| Weight | Approx. 0.40 kg (standard, with 3 m cable); 0.55 kg (L-version) |
| Immersion Depth | Max. 65 mm (standard); max. 150 mm (L-version) |
Request a Quote for Lamtec FFS08 Flame Sensor for Burner Flame Monitoring
Contact Seven Star LLC, an experienced supply partner for Lamtec in Oman and the GCC, for pricing, spectral variant selection, and system integration support for the FFS08 flame sensor and F152 evaluation unit. Our team supports combustion safety and burner management projects across Muscat, Sohar, Salalah, and the wider Sultanate of Oman with genuine Lamtec instrumentation.
Related Products
Datasheets & Documents
- Datasheet LAMTEC FFS08 Flame Sensor Technical Data Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
LAMTEC is a German maker of combustion measurement and control equipment, based in Walldorf, Baden-Württemberg. It introduced its oxygen trim control for burners in 1982 and makes flue gas oxygen and CO/H2 analysers, burner management systems and flame scanners. Its equipment is used on boilers, furnaces and burners in power, process and building plants.
Seven Star LLC lists LAMTEC flame sensors and compact flame scanners and supplies LAMTEC flame monitoring parts to boiler houses and process plants in Oman and the GCC.
LAMTEC company profile
| Location | Walldorf, Germany |
|---|---|
| O2 control since | 1982 |
| Applications | Boilers, furnaces and industrial burners |
| Technology | Zirconia O2 and CO/H2 measurement, flame monitoring |
| Product families | BurnerTronic BT300 burner control, F300K and F200K flame scanners, FFS08 flame sensors, LT1, LT2 and LT3 flue gas analysers |
LAMTEC flame monitoring products
LAMTEC builds flame monitoring in two ways. The FFS07 and FFS08 are separate flame sensors that work with the F152 evaluation unit, which sits in the control cabinet. The F200K and F300K are compact flame scanners that need no separate evaluation unit. The F200K is also made in Ex versions for hazardous areas, and the F200K Ex is listed on this page together with the F300K, the FFS08 and the BurnerTronic BT300 burner control system.
LAMTEC products we list
Ordering LAMTEC flame scanners: what we need
A flame scanner is chosen for the fuel and the burner, so the type designation alone is not enough. Send the full type and article number from the label, the serial number, the fuel or fuels fired, the spectral range of the existing sensor, the supply voltage, cable length, and whether the device stands in a hazardous area. A photo of the label and of the mounting saves time.
Facts checked against LAMTEC exhibitor and company profiles, October 2026.
Browse LAMTEC products by category: Fire & Gas Detector.
FAQ
Questions about the Lamtec FFS08 Flame Sensor for Burner Flame
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between the FFS07 and FFS08 flame sensors?
The FFS07 is aligned axially in the direction of the flame and is available for Ex zones, while the FFS08 is aligned orthogonally to the flame axis and is intended for safe-area use.
02What evaluation unit does the FFS08 require?
The FFS08 is used with the LAMTEC F152 evaluation unit for standalone flame monitoring, or integrates directly with LAMTEC CMS or ETAMATIC burner management systems.
03Is the FFS08 suitable for continuous flame monitoring?
Yes, the FFS08 operates in continuous mode, providing ongoing flame supervision throughout the burner firing cycle rather than intermittent pilot-only monitoring.
04What safety rating does the FFS08 hold?
In combination with the F152 evaluation unit, the FFS08 achieves SIL 3 per DIN EN 61508-2, with EC type examination certification to DIN EN 298.
05Where can I buy genuine Lamtec flame sensors in Oman?
Seven Star LLC is an experienced supplier of Lamtec in Oman and the GCC, supplying genuine FFS08 sensors, F152 evaluation units, and mounting accessories.