Overview
The Dräger Tube 8101211 (Drager 8101211) is a single-use, glass colorimetric detector tube for hydrogen sulfide (H₂S), part of Dräger’s long-established short-term tube program in the “2%/a” range designation. It is not a calibration gas ampoule — it is a direct field-measurement device: a sealed glass tube pre-filled with a chemical reagent that changes color on contact with H₂S, used together with a Dräger accuro® (or accuro® 2000) hand-operated bellows pump to draw a fixed, calibrated volume of ambient air through the tube.
As the sampled air passes through the reagent, the H₂S reacts and produces a visible color-change stain along the length of the tube. The length of this stain is read directly against the tube’s printed scale, giving an immediate, on-the-spot concentration reading without any electronics, batteries, or warm-up time.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Dräger |
| Part Number | 8101211 |
| Product Type | Single-use glass colorimetric detector tube (short-term) |
| Target Gas | Hydrogen sulfide (H₂S) |
| Range Designation | 2%/a |
| Compatible Pump | Dräger accuro® / accuro® 2000 bellows pump |
| Reading | Length-of-stain against printed scale; no power required |
How It Works
Each tube is designed for one measurement only. The operator snaps open both ends of the glass tube, inserts it into the accuro pump, and performs the specified number of pump strokes. Each stroke draws a fixed air sample through the tube; the total stroke count and the resulting stain length together determine the reading on the tube’s pre-printed scale, in line with the 2%/a range this tube is manufactured for.
Applications
Dräger short-term tubes like the 8101211 are widely used across oil & gas facilities, wastewater treatment plants, marine vessels, and confined-space entry programs for quick, independent spot-checks of H₂S concentration — both as a standalone field test and as a practical cross-check against an installed or portable electronic H₂S detector’s reading. Because each tube is single-use and requires no power source, they are valued as a reliable backup method that keeps working even where electronic instruments cannot be deployed or serviced.
Why Choose Seven Star LLC
Seven Star LLC supplies genuine Dräger detector tubes and accessories across Oman and the GCC, backed by proper cold-chain handling and shelf-life tracking that gas-safety tubes require to remain accurate in the field. Because a detector tube’s accuracy depends directly on its expiry date and how it has been stored, customers can ask us to confirm batch and expiry information at quotation for safety-critical H2S monitoring programs, so that anyone who needs a reliable field reading knows the shelf life before ordering.Seven Star LLC supplies this item on request with the manufacturer documentation, and availability and lead time are confirmed at quotation.
For oil and gas facilities, wastewater plants, and confined-space entry programs across the region that rely on Dräger tubes as an independent cross-check against electronic H2S detectors, we help plan consumption-based reordering so field teams are never caught short during an active work program, and we are transparent about remaining shelf life on any stock we quote so your safety team can plan its own usage and disposal schedule with confidence.
Choosing the Right Detector Tube for Your Application
Dräger’s short-term tube program covers many different substances and concentration ranges, and the 8101211’s specific range designation matters as much as the fact that it targets hydrogen sulfide. A tube calibrated for a lower or higher concentration band than what you actually expect on site will either saturate immediately, giving no useful reading, or fail to show a visible stain at all for a genuinely hazardous concentration. Before recommending a tube for a new application, Seven Star LLC asks about your expected exposure range and the specific monitoring scenario, whether that is a confined-space entry check, a leak investigation, or a routine cross-check against installed detectors, so the tube you receive is matched to what you are actually trying to measure.
We also help facilities set up a practical stocking plan around actual usage rates rather than guessing at order quantities, since detector tubes have a finite shelf life and buying too far ahead of need results in expired stock that has to be discarded before it is ever used. For safety teams managing several different tube types across multiple gas hazards, we can consolidate ordering and shipping so your inventory stays current without requiring frequent small orders, and our team remains available to answer questions about proper storage conditions, handling procedures, and disposal of expired tubes in line with standard industrial safety practice. Reach out with your expected H2S exposure range and typical usage volume, and we will confirm the right tube variant, current stock freshness, and a realistic delivery timeline before you place an order, so your safety program is never left waiting on a shipment right when it matters most for your field teams working under real time pressure in the field, not sitting in an office reviewing a datasheet long after the fact. This is the kind of practical, on-the-ground support that makes the difference when a genuine H2S reading needs to be trusted immediately, without hesitation or second-guessing under pressure.
Related Products
- Mitsubishi TN6RPC Gas Tube Dryer Set for NSX-2100 Sulfur Analyzer
- Siemens Maxum II 2-Cell Filament Detector Repair Kit 2020379-701
- Siemens Maxum II SYSCON Replacement Kit Compact Flash 2022018-001
- LAR 501-08-000045 Gas Drying Tube for Carrier TOCUV1A0 – Long
- PR Electronics 5335D 2-Wire HART Transmitter for RTD and TC
- Dräger R-7540
Datasheets & Documents
- Instruction Manual Dräger-Tubes and MicroTubes Handbook Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Gas detection is the part of Dräger that plant safety teams meet first: a Polytron transmitter on a pipe rack, an X-am clipped to a coverall, a box of detector tubes in the permit office. The company was founded in Lübeck, Germany, in 1889. Seven Star LLC sources and supplies Dräger fixed gas transmitters, flame detectors, portable gas detectors and Dräger-Tubes for sites in Oman, and checks each part number against the manufacturer's documentation.
Dräger gas detection product families listed here
Fixed detection is covered by the Polytron line: the Polytron 8100 EC for toxic gases and oxygen with electrochemical sensors, the Polytron 8200 CAT for flammable gases with a catalytic sensor, the Polytron 7000 and the PIR 7000 point infrared detector for hydrocarbons. Dräger flame detectors on this page are the Flame 1500 and Flame 2500 (triple infrared) and the Flame 2700 (multi-infrared). Portable instruments include the Pac 8000 single-gas detector, the X-am 2500 for one to four gases and the X-am 8000 for up to seven. Short-term colorimetric tubes such as Hydrogen Sulfide 100/a (CH29101) are listed with the analyzer accessories.
Where Dräger detectors are used
Polytron transmitters and PIR 7000 heads are found on wellhead and gathering facilities, gas plants, refineries, tank farms, LNG and petrochemical units, and in water treatment chlorine rooms. Portable Dräger gas detectors serve confined space entry, hot work permits and personal H2S monitoring, which is routine on sour fields in the GCC. Detector tubes remain a simple spot check where an electronic sensor is not available for the gas.
Ordering Dräger equipment: what we need
Dräger identifies most items by a seven-digit part number, such as 8101211, and that number is the most direct route to the right quotation. For a fixed transmitter, add the target gas, measuring range, output (4-20 mA, HART or relays), housing material, cable entry thread and the required hazardous-area approval. For portables, list the sensor configuration, pump or diffusion mode and the charger or calibration accessories needed. For tubes, give the gas and the range printed on the box.
Browse Dräger products by category: Fire & Gas Detector, Gas Analyzer Accessories.
Related products
Frequently Asked Questions
No. It is a single-use glass colorimetric detector tube for hydrogen sulfide (H2S) field measurement, not a calibration gas ampoule for testing electronic sensors.
The glass tube is snapped open at both ends, inserted into a Drager accuro bellows hand pump, and a fixed number of pump strokes draws a calibrated air sample through it, producing a color-change stain read against the printed scale.
It measures hydrogen sulfide (H2S) concentration in ambient air, using the 2%/a range formulation of the Drager short-term tube program.
No, each tube is single-use. Once a sample has been drawn through it and the reagent has reacted, the tube is discarded and a fresh tube is used for the next measurement.
It is used for quick field spot-checks of H2S in oil and gas facilities, wastewater treatment plants, marine vessels, and confined-space entry programs, often as an independent backup to electronic gas detectors.

Reviews
There are no reviews yet.