Overview

With the robust Dräger Pac 8000, you’ll be well equipped for tough conditions. This non-disposable, personal single-gas detection device is a reliable and precise instrument that detects hazardous concentrations of 29 different gases, including special gases like H2, NO2, O3, and COCl2 (phosgene). Measured data can easily be transmitted into the Dräger Gas Detection Connect system via Bluetooth.

As a trusted supplier of Dräger safety equipment, Seven Star LLC proudly offers the Pac 8000 to oil and gas, chemical, and industrial safety applications across the Sultanate of Oman, Muscat, and the wider GCC. You can count on the Pac 8000 for reliable, precise readings at any time, even in extreme conditions, thanks to powerful sensors with a fast T-90 response time.

Measurement Principle

The Pac 8000 performs especially well when detecting different special gases: it can detect ozone (O3) from concentrations as low as 0.02ppm and phosgene (COCl2) from 0.01ppm, while detecting nitrogen dioxide (NO2) from concentrations as low as 0.04ppm. The device can be fitted with sensors for a wide range of gases including NO, CO2, Cl2, HCN, NH3, PH3, OV, OV-A, NO2, O3, and COCl2, each with clearly defined measuring ranges and dual alarm setpoints (for example, Cl2 measures 0-20ppm with 0.5/1ppm alarm thresholds, and HCN measures 0-50ppm with 2.5/4.5ppm thresholds).

Beyond the standard alarms, additional thresholds can be defined for TLV (Threshold Limit Values) and STEL (Short Term Exposure Limit), giving safety managers flexibility to match alarm behavior to specific workplace exposure standards. The display can show the peak concentration measured at any given moment, with earlier registered alarms retrievable later even after acknowledgment.

Engineering Design of the Pac 8000

The Pac 8000 measures 64 x 84 x 20mm (without clip) and weighs approximately 106g (113g with clip), with sensors that tolerate air pressures between 700 and 1,300 hPa and relative humidity of 10-90% non-condensing. Its shock-proof, chemical-resistant housing meets the IP68 standard rating, with a membrane filter protecting the sensor from foreign matter such as dust and liquids—user-replaceable when heavily soiled.

Operating temperature spans -30°C to +55°C (briefly to -40°C for 1 hour, depending on sensor), with a minimum 2-year battery service life (12 months for O2 and dual-sensor variants). When hazardous gas concentrations are measured, the device triggers an audible, visual, and vibrating 360° alarm via two bright, flashing LEDs visible from all sides, with an acoustic signal reaching 90dB. The Pac 8000 logs concentrations and events along with date and time, downloadable to a PC or via the X-dock-integrated Gas Detection Connect cloud-based asset management system.

Key Features

The Pac 8000 combines specialized single-gas sensing with rugged field durability. Core capabilities include:

  • Detects 29 different gases including specialty gases NO2, O3, and COCl2 (phosgene).
  • IP68-rated shock-proof, chemical-resistant housing.
  • Fast T-90 sensor response time for quick reactions to gas exposure.
  • Minimum 2-year battery service life (12 months for O2/dual-sensor variants).
  • 360° audible, visual, and vibrating alarm reaching 90dB.
  • Data and event logger with date/time stamping, downloadable via PC.
  • D-Light functionality indicator confirms device readiness.
  • Bluetooth transmission to Dräger Gas Detection Connect system.

Industrial Applications

The Pac 8000 is well suited to oil and gas, chemical processing, and industrial safety programs across Oman requiring dedicated, precise personal monitoring of specific toxic gases. Its ability to detect specialty gases at very low ppm concentrations makes it valuable for applications involving phosgene, ozone, and other hazardous substances requiring exacting sensitivity beyond standard multi-gas monitors.

As a trusted supplier of Dräger safety equipment, Seven Star LLC supports refineries, chemical plants, and industrial safety teams throughout the Sohar and Salalah economic zones and the broader GCC region with the Pac 8000’s proven single-gas detection platform.

Technical Specifications

Full technical parameters for the Dräger Pac 8000 single-gas detector:

Parameter Specification
Model Pac 8000
Detectable Gases 29 Different Gases (Single-Sensor)
Dimensions 64 x 84 x 20mm (Without Clip)
Weight 106g (113g with Clip)
Battery Life Min. 2 Years (12 Months for O2/Dual)
Ingress Protection IP68
Operating Temperature -30°C to +55°C
Alarm 360°, Audible/Visual/Vibrating, 90dB
Connectivity Bluetooth (Gas Detection Connect)

Why Choose Seven Star LLC for Specialty Single-Gas Detection

Specialty gases like phosgene, ozone, and nitrogen dioxide are detected at ppm concentrations low enough that sensor selection and alarm threshold configuration genuinely matter – a generic multi-gas monitor won’t deliver the sensitivity the Pac 8000’s dedicated sensors provide for these substances. Seven Star LLC’s engineers confirm the exact target gas and required TLV/STEL alarm thresholds against the customer’s actual industrial hygiene program before the device is ordered, and help plan a realistic battery and sensor replacement schedule around the platform’s minimum two-year service life. We also support Bluetooth-based fleet management setup via Gas Detection Connect for customers standardizing personal monitoring across multiple sites in Muscat, Sohar, and the broader GCC, and coordinate delivery so specialty-gas coverage isn’t left with a gap during a turnaround.

Request a Quote for Dräger Pac 8000 Single-Gas Detector

To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the Dräger Pac 8000 Single-Gas Detector, please contact Seven Star LLC today. As a trusted supplier of Dräger safety equipment in Oman and the GCC, our engineers are ready to assist with rapid sourcing for your specialty single-gas detection projects.

Related Products

Datasheets & Documents
  • PDF Datasheet Dräger Pac 8000 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Drägerwerk is a German maker of safety and medical technology, founded in Lübeck on 1 January 1889 as Dräger & Gerling by Johann Heinrich Dräger and Carl Adolf Gerling. Its first patent was the Lubeca valve, a pressure reducer for carbon dioxide. Drägerwerk AG is listed on the stock exchange but still controlled by the founding family, led by fifth-generation chairman Stefan Dräger.

Seven Star LLC sources and supplies Dräger fixed gas transmitters, flame detectors, portable gas detectors and Dräger-Tubes for sites in Oman, and checks each part number against the manufacturer's documentation.

Dräger company profile

Founded 1 January 1889, Lübeck, Germany, as Dräger & Gerling
Founders Johann Heinrich Dräger and Carl Adolf Gerling
Headquarters Lübeck, Germany
Ownership Drägerwerk AG & Co. KGaA, listed in Frankfurt; controlled by the Dräger family
Product families Polytron fixed gas detectors, flame detectors, X-am and Pac portable gas detectors, Dräger-Tubes, breathing apparatus, gas detection controllers; anaesthesia, ventilation and patient monitoring in the medical division

Milestones

  • 1889: Dräger & Gerling is founded in Lübeck; the Lubeca valve is its first patent.
  • 1902: Bernhard Dräger joins and the company becomes Drägerwerk Heinr. und Bernh. Dräger.
  • 1907: The Pulmotor resuscitator goes into series production.
  • 1970: Drägerwerk becomes an Aktiengesellschaft.

Dräger gas detection product families listed here

Fixed detection is covered by the Polytron line: the Polytron 8100 EC for toxic gases and oxygen with electrochemical sensors, the Polytron 8200 CAT for flammable gases with a catalytic sensor, the Polytron 7000 and the PIR 7000 point infrared detector for hydrocarbons. Dräger flame detectors on this page are the Flame 1500 and Flame 2500 (triple infrared) and the Flame 2700 (multi-infrared). Portable instruments include the Pac 8000 single-gas detector, the X-am 2500 for one to four gases and the X-am 8000 for up to seven. Short-term colorimetric tubes such as Hydrogen Sulfide 100/a (CH29101) are listed with the analyzer accessories.

Where Dräger detectors are used

Polytron transmitters and PIR 7000 heads are found on wellhead and gathering facilities, gas plants, refineries, tank farms, LNG and petrochemical units, and in water treatment chlorine rooms. Portable Dräger gas detectors serve confined space entry, hot work permits and personal H2S monitoring, which is routine on sour fields in the GCC. Detector tubes remain a simple spot check where an electronic sensor is not available for the gas.

Dräger products we list

Family Examples
Fire & Gas Detectors Flame 1500 (IR3) Flame Detector, Flame 2500 (IR3) Flame Detector, Flame 2700 (Multi-IR) Flame Detector, Pac 8000 Single-Gas Detector, PIR 7000 Point Infrared Gas Detector, Polytron 7000 Gas Detector, Polytron 8100 EC Toxic Gas Transmitter, Polytron 8200 CAT Flammable Gas Transmit… and 2 more
Gas Analyzer Accessories 8101211, Gastec No.4HH Hydrogen Sulphide H2S Dete…, Tube: Hydrogen Sulfide 100/a (CH29101)

Ordering Dräger equipment: what we need

Dräger identifies most items by a seven-digit part number, such as 8101211, and that number is the most direct route to the right quotation. For a fixed transmitter, add the target gas, measuring range, output (4-20 mA, HART or relays), housing material, cable entry thread and the required hazardous-area approval. For portables, list the sensor configuration, pump or diffusion mode and the charger or calibration accessories needed. For tubes, give the gas and the range printed on the box.

Facts checked against Dräger's own history pages (draeger.com) and published company histories, October 2026.

FAQ

Questions about the Dräger Pac 8000 Single-Gas Detector

Answers from our engineering team on installation, compatibility and integration.

01How many gases can the Pac 8000 detect?
The Pac 8000 can detect hazardous concentrations of 29 different gases, including specialty gases like H2, NO2, O3, and COCl2 (phosgene).
02How sensitive is the Pac 8000 to specialty gases?
It can detect ozone from concentrations as low as 0.02 ppm, phosgene from 0.01 ppm, and nitrogen dioxide from 0.04 ppm.
03How long does the Pac 8000 battery last?
The battery service life is a minimum of 2 years, or 12 months for O2 and dual-sensor variants.
04Can the Pac 8000 transmit data wirelessly?
Yes. Measured data can be transmitted via Bluetooth into the Dru00e4ger Gas Detection Connect system for cloud-based asset management.
05Is Seven Star LLC a trusted supplier for Dru00e4ger products?
Yes. Seven Star LLC is an experienced supplier of Dru00e4ger safety equipment in Oman and the GCC, providing genuine products with full support.