Brand:

Dräger PIR 7000 Point Infrared Gas Detector

Description

Overview

The Dräger PIR 7000 is an explosion-proof point gas detection transmitter that uses infrared (IR) technology to continuously monitor hydrocarbon gases in %LEL or ppm. With its stainless steel SS 316L enclosure and drift-free optics, this detector is built for the harshest industrial environments, including offshore installations.

As a trusted supplier of Dräger safety equipment, Seven Star LLC proudly offers the PIR 7000 to oil and gas, petrochemical, and offshore facilities across the Sultanate of Oman, Muscat, and the wider GCC. Two models are available—type 334 and type 340—each operating at a different measuring wavelength to give the broadest possible range of detectable substances with superior accuracy.

Measurement Principle

The PIR 7000 builds on the success of the Dräger Polytron IR, the most stable point infrared gas detector worldwide, combining a maximum light-collecting construction with a 4-beam signal-stabilizing system. The total optical system uses no light beam split, simply a set of various reflectors, making this double-compensating, non-imaging optical design highly resistant to dust, fog, insects, and dirt accumulation on the optical surface.

Because the measuring signal is not affected by a partial beam block, the PIR 7000 fulfills demanding requirements for no false alarms, longer service intervals, and drift-free signal output. The detector comes standard with 3 embedded gases (methane, propane, ethylene) with capacity for up to 10 embedded gases, selectable from a library of over 80 available gases using Dräger Polysoft Premium software, with switching between target gases requiring no recalibration.

Engineering Design of the PIR 7000

The PIR 7000 operates from a 9 to 30VDC power supply (13 to 30VDC for HART operation) across an extended operating temperature range of -40°F to +170.6°F, with IP66/67 ingress protection in a hermetically sealed stainless steel SS 316L enclosure measuring 6.3 x 3.5 x 3.5 inches and weighing 4.85 lbs. The measuring range can be freely adjusted between 0-350ppm and 0-100% LEL, enabling a wide variety of applications, and the device offers a configurable response mode allowing users to choose between “normal” or “high speed” response depending on the application.

The device is available with either M25 or 3/4-inch NPT cable entry and outputs a conventional 4-20mA analog signal with single cable multidrop capability via HART communication. Developed and manufactured according to SIL guidelines, the PIR 7000 not only meets but exceeds SIL 2 (IEC 61508) requirements, with continuous self-testing, no moving parts, resistance to shock and vibration up to 4G, and a typical lifetime greater than 15 years.

Key Features

The PIR 7000 combines proven 4-beam infrared optics with extensive configurability. Core capabilities include:

  • Hermetically sealed stainless steel SS 316L enclosure for the harshest environments.
  • 4-beam signal-stabilizing, double-compensating optics resistant to dust, fog, and insects.
  • SIL 2 certified (exceeds requirements) per IEC 61508.
  • Response time of less than 1 second in high-speed mode.
  • Configurable gas library (3 fixed, up to 10 embedded, 80+ available substances).
  • Beam block warning for scheduled preventive maintenance.
  • 4-20mA analog output with HART single cable multidrop capability.
  • ATEX, IECEx, UL, and CSA hazardous area approvals for worldwide application.

Industrial Applications

The PIR 7000 is well suited to offshore platforms, refineries, and petrochemical plants across Oman requiring reliable, drift-free continuous monitoring of flammable hydrocarbon gases and vapours. Its resistance to dust, fog, and insect intrusion, combined with long maintenance intervals, makes it a dependable choice for remote or difficult-to-access installations throughout the region.

As a trusted supplier of Dräger safety equipment, Seven Star LLC supports oil and gas facilities, chemical plants, and marine installations throughout the Sohar and Salalah economic zones and the broader GCC region with the PIR 7000’s proven infrared gas detection platform.

Technical Specifications

Full technical parameters for the Dräger PIR 7000 point infrared gas detector:

Parameter Specification
Model PIR 7000 (Type 334 or Type 340)
Measuring Principle Infrared (4-Beam Signal Stabilizing)
Response Time < 1 Second (High-Speed Mode)
Measuring Range 0-350 ppm; 0-100% LEL (Adjustable)
Power Supply 9 to 30 VDC (13 to 30 VDC for HART)
Operating Temperature -40°F to +170.6°F
Housing Material Stainless Steel SS 316L
Ingress Protection IP66/67
Cable Entry M25 or 3/4″ NPT
Output 4-20mA Analog, HART
Safety Rating SIL 2 (IEC 61508)
Hazardous Area Approvals ATEX, IECEx, UL, CSA

Why Choose Seven Star LLC for Fixed Gas Detection Sourcing

Selecting between the PIR 7000’s type 334 and type 340 wavelength variants, and configuring the correct embedded gas library, depends on the exact hydrocarbon mixture present at a given detection point – a mismatch reduces sensitivity to the actual gas of concern even though the detector appears to be functioning normally. Seven Star LLC’s engineers review the process gas composition and detection-point layout with the customer before the PIR 7000 is ordered, confirming wavelength type, measuring range, and cable entry standard (M25 or NPT) against the site’s existing conduit and instrumentation practice. For offshore and coastal installations across Oman we also confirm the SS 316L enclosure and IP66/67 rating are appropriate for the salt-air exposure involved, and we plan spare-unit stock so a failed detector on a safety-critical gas detection loop can be replaced without leaving a coverage gap.

Request a Quote for Dräger PIR 7000 Point Infrared Gas Detector

To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the Dräger PIR 7000 Point Infrared Gas Detector, please contact Seven Star LLC today. As a trusted supplier of Dräger safety equipment in Oman and the GCC, our engineers are ready to assist with rapid sourcing for your flammable gas detection projects.

Related Products

Datasheets & Documents
  • PDF Datasheet Dräger PIR 7000 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Drägerwerk is a German maker of safety and medical technology, founded in Lübeck on 1 January 1889 as Dräger & Gerling by Johann Heinrich Dräger and Carl Adolf Gerling. Its first patent was the Lubeca valve, a pressure reducer for carbon dioxide. Drägerwerk AG is listed on the stock exchange but still controlled by the founding family, led by fifth-generation chairman Stefan Dräger.

Seven Star LLC sources and supplies Dräger fixed gas transmitters, flame detectors, portable gas detectors and Dräger-Tubes for sites in Oman, and checks each part number against the manufacturer's documentation.

Dräger company profile

Founded 1 January 1889, Lübeck, Germany, as Dräger & Gerling
Founders Johann Heinrich Dräger and Carl Adolf Gerling
Headquarters Lübeck, Germany
Ownership Drägerwerk AG & Co. KGaA, listed in Frankfurt; controlled by the Dräger family
Product families Polytron fixed gas detectors, flame detectors, X-am and Pac portable gas detectors, Dräger-Tubes, breathing apparatus, gas detection controllers; anaesthesia, ventilation and patient monitoring in the medical division

Milestones

  • 1889: Dräger & Gerling is founded in Lübeck; the Lubeca valve is its first patent.
  • 1902: Bernhard Dräger joins and the company becomes Drägerwerk Heinr. und Bernh. Dräger.
  • 1907: The Pulmotor resuscitator goes into series production.
  • 1970: Drägerwerk becomes an Aktiengesellschaft.

Dräger gas detection product families listed here

Fixed detection is covered by the Polytron line: the Polytron 8100 EC for toxic gases and oxygen with electrochemical sensors, the Polytron 8200 CAT for flammable gases with a catalytic sensor, the Polytron 7000 and the PIR 7000 point infrared detector for hydrocarbons. Dräger flame detectors on this page are the Flame 1500 and Flame 2500 (triple infrared) and the Flame 2700 (multi-infrared). Portable instruments include the Pac 8000 single-gas detector, the X-am 2500 for one to four gases and the X-am 8000 for up to seven. Short-term colorimetric tubes such as Hydrogen Sulfide 100/a (CH29101) are listed with the analyzer accessories.

Where Dräger detectors are used

Polytron transmitters and PIR 7000 heads are found on wellhead and gathering facilities, gas plants, refineries, tank farms, LNG and petrochemical units, and in water treatment chlorine rooms. Portable Dräger gas detectors serve confined space entry, hot work permits and personal H2S monitoring, which is routine on sour fields in the GCC. Detector tubes remain a simple spot check where an electronic sensor is not available for the gas.

Dräger products we list

Family Examples
Fire & Gas Detectors Flame 1500 (IR3) Flame Detector, Flame 2500 (IR3) Flame Detector, Flame 2700 (Multi-IR) Flame Detector, Pac 8000 Single-Gas Detector, PIR 7000 Point Infrared Gas Detector, Polytron 7000 Gas Detector, Polytron 8100 EC Toxic Gas Transmitter, Polytron 8200 CAT Flammable Gas Transmit… and 2 more
Gas Analyzer Accessories 8101211, Gastec No.4HH Hydrogen Sulphide H2S Dete…, Tube: Hydrogen Sulfide 100/a (CH29101)

Ordering Dräger equipment: what we need

Dräger identifies most items by a seven-digit part number, such as 8101211, and that number is the most direct route to the right quotation. For a fixed transmitter, add the target gas, measuring range, output (4-20 mA, HART or relays), housing material, cable entry thread and the required hazardous-area approval. For portables, list the sensor configuration, pump or diffusion mode and the charger or calibration accessories needed. For tubes, give the gas and the range printed on the box.

Facts checked against Dräger's own history pages (draeger.com) and published company histories, October 2026.

FAQ

Questions about the Dräger PIR 7000 Point Infrared Gas Detector

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between PIR 7000 type 334 and type 340?
Each model operates at a different measuring wavelength, giving the broadest possible range of detectable flammable substances with superior accuracy depending on the application.
02How many gases can the PIR 7000 detect?
It comes standard with 3 embedded gases (methane, propane, ethylene) and can store up to 10 embedded gases, selectable from a library of over 80 available substances.
03Is the PIR 7000 SIL certified?
Yes. The PIR 7000 is developed according to the Functional Safety standard EN 61508 and not only meets but exceeds SIL 2 requirements.
04How fast does the PIR 7000 respond to a gas leak?
Using the configurable high-speed response mode combined with the lowest feasible alarm threshold, the PIR 7000 achieves a response time of less than 1 second.
05Is Seven Star LLC a supplier of Dräger products?
Yes. Seven Star LLC is an experienced supplier of Dräger safety equipment in Oman and the GCC, supplied on request.