Brand:

Allen-Bradley 2198-S160-ERS3 Kinetix 5700 Single-Axis Inverter

Description

100 mm Kinetix 5700 single-axis inverter, 85.0 A rms

If your machine design is built on the Kinetix 5700 DC-bus architecture, 2198-S160-ERS3 is the single-axis inverter with 85.0 A rms continuous output. It accepts 276 to 747V DC, draws 92.3 A of DC input at rating, and delivers up to 160.0 A rms for one second. Continuous power is 60.1 kW at 480V three-phase (30.1 kW at 240V at half power).

At 100 mm wide it suits high-power single-axis duties such as extruder drives, large rolls or heavy test benches.

Position in the family: the single-axis range runs 2198-S086 (43 A), S130 (65 A), S160 (85 A), S263 (150 A) and S312 (192 A) rms. Rockwell allows 160.0 A rms for 1.0 s, around 1.88 times the continuous rating (derived), so size the motor and the move profile accordingly.

Technical specifications

Parameter Specification
Catalog no. 2198-S160-ERS3
Drive type Kinetix 5700 single-axis inverter, EtherNet/IP
Output current (rms / 0-pk) 85.0 A rms / 120.2 A 0-pk
Peak (rms / 0-pk) 160.0 A rms / 226.2 A 0-pk
Output power 60.1 kW at 480V three-phase (30.1 kW at 240V at half power)
DC bus current 92.3 A
PWM frequency 4 kHz
Module width 100 mm
Power dissipation 270 W at 20% to 950 W at 100%
DC input voltage 276 to 747V DC
Weight 6.80 kg (15.0 lb)

System architecture and DC bus

A Kinetix 5700 system pairs one or more inverters with a DC-bus power supply (2198-P031, P070, P141 or P208) or a regenerative bus supply (2198-RP088 to RP312), joined by a snap-fit bus system. The datasheet lists the inverter’s DC input current as 92.3 A and its internal capacitance as 1120 microfarads, and capacitor modules can add energy storage.

Control power is 24V DC to every module, and the recommended minimum cabinet depth is 300 mm. Maximum motor cable length depends on the supply and filter used: up to 400 m with a 2198-DBxx-F EMC line filter, or up to 1200 m with a 2198-DBRxx-F filter.

Heat, cabinet space and weight

The datasheet’s power-dissipation table gives 270 W at 20% of rated output rising to 950 W at 100%. Add this to the panel heat budget. The module weighs 6.80 kg (15.0 lb), and 100 mm of width per module allows tight side-by-side lineups.

Rockwell states that the Kinetix 5700 power density can reduce cabinet space by up to 67% compared with older solutions, a figure from its marketing literature rather than a measurement for this catalog number.

Ordering and documents

Specify 2198-S160-ERS3 in full, together with the DC-bus supply, 24V control supply, motor cables and any capacitor or shunt modules, which are separate catalog numbers. The linked file is 2198-PP002 (Kinetix 5700 product profile) and the tables are from KNX-TD003N, June 2026.

We are an independent supplier in Muscat. Please verify every value with the current Rockwell literature before ordering.

When asking about 2198-S160-ERS3, please include the motor catalog numbers, the cable lengths, the supply voltage, whether the machine uses the hardwired or the integrated safety function, and the network architecture. Servo systems are assembled from several catalog numbers, and a complete list avoids delays and mismatched parts (Kinetix 5700 single-axis inverter, 85.0 A rms , 60.1 kW at 480V, EtherNet/IP).

Browse more items in Servo Drives on our site, or send us the part number for a quotation.

Datasheets & Documents
  • PDF Product Profile Kinetix 5700 Servo Drives Product Profile (2198-PP002) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Allen-Bradley is the brand of Rockwell Automation for industrial control: ControlLogix and CompactLogix controllers, I/O systems, PanelView operator terminals, PowerFlex drives, motor control and industrial network equipment. The company began in Milwaukee in 1903, when Lynde Bradley and Dr. Stanton Allen formed the Compression Rheostat Company to make the motor speed controller Bradley had invented in 1901. It took the name Allen-Bradley in 1909 and was bought by Rockwell International in 1985. Since 2001 its owner has been Rockwell Automation, which is still headquartered in Milwaukee, Wisconsin.

Allen-Bradley company profile

Founded 1903, Milwaukee, Wisconsin, USA, as the Compression Rheostat Company
Founders Lynde Bradley (inventor of the compression rheostat, 1901) and Dr. Stanton Allen (investor); Harry Bradley joined in 1904
Name Allen-Bradley Company from 1909
Ownership Acquired by Rockwell International in 1985 for about USD 1.65 billion; a brand of Rockwell Automation (NYSE: ROK) since 2001
Headquarters Milwaukee, Wisconsin, USA
Product families Logix programmable automation controllers (ControlLogix, CompactLogix), legacy SLC 500 and MicroLogix PLCs, Micro800 controllers, POINT, FLEX and Compact I/O, PanelView HMIs, PowerFlex AC drives, contactors, motor starters and soft starters, safety components, Stratix Ethernet switches

Milestones

  • 1901: Lynde Bradley invents the compression rheostat to control the speed of electric motors.
  • 1903: The Compression Rheostat Company is formed in Milwaukee with an initial investment of USD 1,000.
  • 1904: Harry Bradley joins; a crane controller is shown at the St. Louis World's Fair.
  • 1909: The company is renamed Allen-Bradley.
  • 1985: Rockwell International acquires Allen-Bradley.
  • 2001: Rockwell Automation becomes the company's name; the Allen-Bradley brand marks 100 years in 2003.

Reading Allen-Bradley catalogue numbers

The first digits of an Allen-Bradley catalogue number identify the platform, which tells you what is compatible with what. 1756 is ControlLogix (chassis-based, used for large process and plant control), 1769 is CompactLogix 5370 with Compact I/O, 5069 is CompactLogix 5380 with Compact 5000 I/O, 1734 is POINT I/O, 1794 and 5094 are FLEX and FLEX 5000 distributed I/O, 1746 and 1747 belong to the older SLC 500 family, 1766 is MicroLogix 1400 and 2080 is Micro800. For drives, 25B is PowerFlex 525 and 22B is PowerFlex 40; in a code such as 25B-D010N114, "D" means 380–480 V, "010" is the output current rating, and N114 instead of N104 means the drive has an integrated EMC filter. Many plants in the region still run SLC 500 and older MicroLogix systems, which Rockwell has discontinued, so exact spares and migration to CompactLogix are both common requests.

Where Allen-Bradley products are used

In Oman and the GCC, Allen-Bradley controllers and drives run on oil and gas facilities, water treatment and pumping stations, cement, food and beverage and packaging plants, and on machines supplied by American OEMs. ControlLogix is often the platform for plant control systems, while PowerFlex drives are used on pumps, fans and conveyors.

Allen-Bradley products we list

Family Examples
ControlLogix 1756-L85E, 1756-EN2T, 1756-EN2TR, 1756-IF16, 1756-IB32, 1756-PA75, 1756-A10
CompactLogix and Micro controllers 5069-L320ER, 5069-L340ERM, 1769-L33ER, 1769-L16ER, MicroLogix 1400, Micro820, SLC 500 (1746)
Distributed I/O 1734-AENTR, 1734-IB8, 1734-IE2C, 1734-IB8S safety, 1794-AENTR, 5094-AENTR, 5069-IF8
Operator terminals PanelView Plus 7 10-inch, PanelView Plus 7 15-inch, PanelView 800, PanelView 5310
Drives, motor control and networking PowerFlex 525, PowerFlex 755, PowerFlex 4, 150-A180NBD SMC, Stratix 2000, 1783-NATR

Ordering Allen-Bradley products: what we need

Send the full catalogue number and the series letter from the label (for example 1756-EN2T Series D), because firmware and compatibility can change between series. For drives, add the motor power, voltage and filter option. For a discontinued SLC 500 or MicroLogix part, tell us whether you need the exact spare or a migration proposal.

Facts checked against Rockwell Automation's published company history, October 2026.

FAQ

Questions about the Allen-Bradley 2198-S160-ERS3 Kinetix 5700

Answers from our engineering team on installation, compatibility and integration.

01What current does 2198-S160-ERS3 deliver?
85.0 A rms continuous, with a peak of 160.0 A rms for one second.
02Is 2198-S160-ERS3 single-axis or dual-axis?
It is a single-axis inverter module, 100 mm wide.
03What supplies power to 2198-S160-ERS3?
A DC bus of 276 to 747V DC from a Kinetix 5700 DC-bus power supply or regenerative bus supply, plus 24V DC control power.
04How much heat does 2198-S160-ERS3 dissipate?
Rockwell lists 270 W at 20% of rated output and 950 W at 100%.
05What safety does 2198-S160-ERS3 support?
Integrated or hardwired Safe Torque-Off to SIL3 PLe; ERS3 drives offer both hardwired and integrated STO modes.