Allen-Bradley 2198-P031 Kinetix 5700 7 kW DC-Bus Supply

Description

Kinetix 5700 DC-bus power supply, 7 kW at 480V

The Allen-Bradley 2198-P031 converts a three-phase 195 to 528V AC line (240/480V nominal) into the 276 to 747V DC bus that Kinetix 5700 inverters share. It is 55 mm wide and weighs 4.33 kg (9.55 lb). Rockwell prints a continuous output of 10.5 A DC and 7.0 kW at 480V (3.5 kW at 240V at half power), with a peak of 31.6 A DC and 21.0 kW at 480V.

It is the right size for a compact system of a few small axes, such as a dual-axis 2198-D006 and one or two additional inverters. AC input current is 11.2 A at rating with up to 33.4 A peak, and the maximum inrush is 33.0 A zero-to-peak.

Technical specifications

Parameter Specification
Catalog number 2198-P031
Type Kinetix 5700 DC-bus power supply
AC input 195-528V rms three-phase (240/480V nom), 47-63 Hz
Main AC input current 11.2 A (peak 33.4 A)
Continuous output to bus 10.5 A DC; 7.0 kW at 480V; 3.5 kW at 240V (half power)
Peak output to bus 31.6 A DC; 21.0 kW at 480V
Bus voltage 276 to 747V DC nominal
Internal shunt 37.5 ohm, 75 W
Capacitance / energy 585 uF / 129 J
Weight / width 4.33 kg (9.55 lb) / 55 mm
Efficiency 99%

Bus supply specifications in context

The supply has an internal shunt of 37.5 ohm, 75 W, an internal capacitance of 585 microfarads and absorbs 129 J of capacitive energy. Bus overvoltage trips at 460V DC on 240V nominal input and 832V DC on 480V nominal input, and efficiency is 99%. Control power is 24V DC at 0.8 A, and the short-circuit current rating is 200,000 A (rms) symmetrical.

Shunt turn-on is 775V DC plus 30V times the bus-regulator utilization on 480V systems, which spreads shunting between modules on the same bus.

Protection, contactor and installation

For UL/CSA installations the KNX-TD003N table lists a LPJ-15SP (15 A) UL fuse or 16 A DIN gG fuse, and 1489-M3D250 miniature breaker, 140M-D8E-C25 or 140MT-D9E-C25 motor protection breaker, or 140G-G6C3-C25 molded-case breaker. The contactor in the datasheet table is the 100-C16EJ10; a contactor-enable relay output (CED connector, rated 24V DC, 1.0 A) lets the drive control it. Dissipation is 97 W at 20% to 113 W at 100%.

The installation instructions call for M5 bolts torqued to 4.0 N-m, 40 mm of clearance above for airflow and a 300 mm minimum cabinet depth. The supply ships with DC-bus end caps and the mains (IPD), control (CP), I/O (IOD), shunt (RC) and contactor-enable (CED) connector set.

Ordering and documents

Quote 2198-P031 in full and plan the line filter (2198-DBxx-F family), contactor, inverters and 24V control supply separately. The hosted document is the installation instruction 2198-IN009, which covers all four DC-bus supplies from 2198-P031 to 2198-P208; ratings come from KNX-TD003N (June 2026).

Seven Star LLC is an independent supplier in Muscat and quotes on request; confirm all values against current Rockwell documents before ordering.

For a servo project built around 2198-P031, tell us the axis count, the motors and cables in use, the supply voltage, the safety concept (hardwired or integrated) and the controller platform. A complete Kinetix system also needs power supplies, cables and filters, and a short parts list lets us check that nothing essential is missing before the quotation (Kinetix 5700 DC-bus power supply, 10.5 A DC, 7.0 kW at 480V, 55 mm).

Browse more items in Servo Drives on our site, or send us the part number for a quotation.

Datasheets & Documents
  • PDF Installation Instructions Kinetix 5700 DC-bus Power Supply Installation Instructions (2198-IN009) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Allen-Bradley is the brand of Rockwell Automation for industrial control: ControlLogix and CompactLogix controllers, I/O systems, PanelView operator terminals, PowerFlex drives, motor control and industrial network equipment. The company began in Milwaukee in 1903, when Lynde Bradley and Dr. Stanton Allen formed the Compression Rheostat Company to make the motor speed controller Bradley had invented in 1901. It took the name Allen-Bradley in 1909 and was bought by Rockwell International in 1985. Since 2001 its owner has been Rockwell Automation, which is still headquartered in Milwaukee, Wisconsin.

Allen-Bradley company profile

Founded 1903, Milwaukee, Wisconsin, USA, as the Compression Rheostat Company
Founders Lynde Bradley (inventor of the compression rheostat, 1901) and Dr. Stanton Allen (investor); Harry Bradley joined in 1904
Name Allen-Bradley Company from 1909
Ownership Acquired by Rockwell International in 1985 for about USD 1.65 billion; a brand of Rockwell Automation (NYSE: ROK) since 2001
Headquarters Milwaukee, Wisconsin, USA
Product families Logix programmable automation controllers (ControlLogix, CompactLogix), legacy SLC 500 and MicroLogix PLCs, Micro800 controllers, POINT, FLEX and Compact I/O, PanelView HMIs, PowerFlex AC drives, contactors, motor starters and soft starters, safety components, Stratix Ethernet switches

Milestones

  • 1901: Lynde Bradley invents the compression rheostat to control the speed of electric motors.
  • 1903: The Compression Rheostat Company is formed in Milwaukee with an initial investment of USD 1,000.
  • 1904: Harry Bradley joins; a crane controller is shown at the St. Louis World's Fair.
  • 1909: The company is renamed Allen-Bradley.
  • 1985: Rockwell International acquires Allen-Bradley.
  • 2001: Rockwell Automation becomes the company's name; the Allen-Bradley brand marks 100 years in 2003.

Reading Allen-Bradley catalogue numbers

The first digits of an Allen-Bradley catalogue number identify the platform, which tells you what is compatible with what. 1756 is ControlLogix (chassis-based, used for large process and plant control), 1769 is CompactLogix 5370 with Compact I/O, 5069 is CompactLogix 5380 with Compact 5000 I/O, 1734 is POINT I/O, 1794 and 5094 are FLEX and FLEX 5000 distributed I/O, 1746 and 1747 belong to the older SLC 500 family, 1766 is MicroLogix 1400 and 2080 is Micro800. For drives, 25B is PowerFlex 525 and 22B is PowerFlex 40; in a code such as 25B-D010N114, "D" means 380–480 V, "010" is the output current rating, and N114 instead of N104 means the drive has an integrated EMC filter. Many plants in the region still run SLC 500 and older MicroLogix systems, which Rockwell has discontinued, so exact spares and migration to CompactLogix are both common requests.

Where Allen-Bradley products are used

In Oman and the GCC, Allen-Bradley controllers and drives run on oil and gas facilities, water treatment and pumping stations, cement, food and beverage and packaging plants, and on machines supplied by American OEMs. ControlLogix is often the platform for plant control systems, while PowerFlex drives are used on pumps, fans and conveyors.

Allen-Bradley products we list

Family Examples
ControlLogix 1756-L85E, 1756-EN2T, 1756-EN2TR, 1756-IF16, 1756-IB32, 1756-PA75, 1756-A10
CompactLogix and Micro controllers 5069-L320ER, 5069-L340ERM, 1769-L33ER, 1769-L16ER, MicroLogix 1400, Micro820, SLC 500 (1746)
Distributed I/O 1734-AENTR, 1734-IB8, 1734-IE2C, 1734-IB8S safety, 1794-AENTR, 5094-AENTR, 5069-IF8
Operator terminals PanelView Plus 7 10-inch, PanelView Plus 7 15-inch, PanelView 800, PanelView 5310
Drives, motor control and networking PowerFlex 525, PowerFlex 755, PowerFlex 4, 150-A180NBD SMC, Stratix 2000, 1783-NATR

Ordering Allen-Bradley products: what we need

Send the full catalogue number and the series letter from the label (for example 1756-EN2T Series D), because firmware and compatibility can change between series. For drives, add the motor power, voltage and filter option. For a discontinued SLC 500 or MicroLogix part, tell us whether you need the exact spare or a migration proposal.

Facts checked against Rockwell Automation's published company history, October 2026.

FAQ

Questions about the Allen-Bradley 2198-P031 Kinetix 5700 7 kW DC-Bus

Answers from our engineering team on installation, compatibility and integration.

01What is the continuous output of 2198-P031?
10.5 A DC to the bus, or 7.0 kW at 480V three-phase.
02What AC supply does 2198-P031 need?
Three-phase 195 to 528V rms (240/480V nominal) at 47 to 63 Hz, plus 24V DC control power.
03Does 2198-P031 include a shunt?
Yes, an internal shunt of 37.5 ohm, 75 W.
04Which contactor does Rockwell list for 2198-P031?
The 100-C16EJ10 in the DC-bus power supply contactor table.
05How wide is 2198-P031?
55 mm and 4.33 kg (9.55 lb).