- Automation & ControlView all 3,073 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Mitsubishi
Mitsubishi MR-J3-100BS4 Servo Amplifier
Description
Mitsubishi MR-J3-100BS4 safety servo amplifier overview
The Mitsubishi MR-J3-100BS4 is a 1 kW MELSERVO-J3 servo amplifier for three-phase 380–480 V AC supplies. It has an SSCNET III fibre-optic interface and a built-in Safe Torque Off (STO) function. It belongs to the MR-J3-B Safety range, which adds functional safety to the standard MR-J3-B amplifier while keeping the same mounting, wiring and connectors. Seven Star LLC supplies the Mitsubishi MR-J3-100BS4 on request for machine builders and maintenance teams in Oman and the GCC.
In the model code, the letter B means the SSCNET III interface type, S means the safety version, the final 4 means a 400 V class supply (three-phase 380–480 V AC), and 100 means the 1 kW rated output class. The amplifier works with a motion controller such as a Mitsubishi Q-series motion CPU or a simple motion module over the optical SSCNET III network.
Key features
- Safe Torque Off (STO) built into the amplifier, to IEC/EN 61800-5-2.
- Safe Stop 1 (SS1) when combined with the separate MR-J3-D05 safety logic unit.
- Safety performance of EN ISO 13849-1 PL d (Category 3), IEC/EN 61508 SIL 2 and IEC/EN 62061 SIL CL 2.
- SSCNET III fibre-optic motion network for high noise immunity and simple daisy-chain wiring.
- High-resolution encoder support of 262144 pulses/rev with compatible HF-SP and HF-JP motors.
- Position, speed and torque control as commanded by the controller.
- Absolute position system when a battery is fitted.
- Built-in dynamic brake for stopping the motor at alarms and power loss.
Technical specifications
| Parameter | Specification |
|---|---|
| Model | MR-J3-100BS4 (MR-J3-B Safety series) |
| Rated output | 3-phase 323 V AC, 2.8 A |
| Main circuit power supply | 3-phase 380–480 V AC, 50/60 Hz; rated input current 2.5 A |
| Permissible voltage fluctuation | 3-phase 323–528 V AC |
| Permissible frequency fluctuation | Within ±5% |
| Control circuit power supply | 1-phase 380–480 V AC (permissible 323–528 V AC) |
| Interface power supply | 24 V DC ±10%, 0.2 A (including CN8) |
| Control system | Sine-wave PWM control, current control system |
| Dynamic brake | Built in |
| Safety function | STO (IEC/EN 61800-5-2); response time 8 ms or less |
| Safety performance | EN ISO 13849-1 PL d (Cat. 3); IEC/EN 61508 SIL 2; IEC/EN 62061 SIL CL 2 |
| Test pulse input | Interval 1–25 Hz; OFF time up to 1 ms |
| Compliance | CE (LVD: EN 50178; EMC: IEC/EN 61800-3); UL 508C |
| Structure | Open (IP00) |
| Ambient temperature | 0–55 °C operating; −20–65 °C storage |
| Ambient humidity | 90% RH or less, non-condensing |
| Altitude and vibration | 1000 m or less; 5.9 m/s² at 10–55 Hz |
| Mass | 1.7 kg |
Operating principle
The Mitsubishi MR-J3-100BS4 rectifies the three-phase supply to a DC bus, then drives the motor through an IGBT inverter using sine-wave PWM with a current control loop. The controller sends position or speed commands over SSCNET III, and the amplifier closes the current, speed and position loops using the motor encoder feedback. For STO, two safety input channels on connector CN8 remove the drive signals to the power stage, so the motor cannot produce torque. The manual gives a response of 8 ms or less from STO input OFF to energy shut-off. With the MR-J3-D05, the motor is first decelerated and STO is applied after a set delay, which gives a Stop Category 1 (SS1) stop.
Compatible motors for the Mitsubishi MR-J3-100BS4
- HF-SP1024 (2000 r/min, medium inertia).
- HF-JP734 and HF-JP1034 (3000 r/min, low inertia).
- HF-JP534, supported when the 400% maximum torque setting is used.
Always confirm the motor and amplifier pairing in the manual, because the encoder and parameter settings depend on the combination.
Typical applications of the Mitsubishi MR-J3-100BS4
- Machine axes where an operator enters the danger zone and torque must be removed safely without cutting the main supply.
- Packaging, printing and converting machines with several synchronised servo axes on SSCNET III.
- Material handling and press-feed equipment that needs SS1 stopping with the MR-J3-D05.
- Plants running on 400 V class supplies, where a 400 V amplifier avoids a step-down transformer.
Installation and commissioning
The Mitsubishi MR-J3-100BS4 is an open IP00 unit and must be installed in a cabinet that protects it from dust and conductive contamination. Keep the clearances given in the manual for cooling. Wire the safety signals to CN8 with the STO cable (MR-D05UDL3M-B when connecting to the MR-J3-D05). If STO is not used, fit the short-circuit connector supplied for that purpose, following the manual. Connect the SSCNET III optical cable, set the axis number, then load parameters from the controller. Before handing the machine over, validate the safety function as part of the machine risk assessment. The amplifier alone does not define the safety level of the machine.
Mitsubishi MR-J3-100BS4 maintenance and troubleshooting
- Alarms: read the alarm number on the display and look it up in the manual. Overcurrent, overvoltage and encoder alarms point to different areas of the system.
- STO-related warning: check the 24 V DC interface supply, the CN8 wiring and the safety relay or MR-J3-D05 outputs.
- Cooling: clean the cabinet filters and check the fan. In Gulf summer conditions, cabinet temperature can approach the 55 °C limit.
- Absolute position lost: replace the encoder battery and perform home position return.
- Electrolytic capacitors and fan: these are life-limited parts. The manual gives guidance on replacement intervals.
Mitsubishi MR-J3-100BS4 legacy and replacement notes
Mitsubishi Electric sales and service bulletin 17-06BE announced that the MR-J3 series moved to made-to-order production from 31 May 2018, with orders accepted until 31 May 2019. The bulletin set 31 May 2026 as the end of repairs and parts supply, and that date has now passed, so check stock with us and service options with Mitsubishi Electric before planning on this drive. The MR-J4 series is named as the replacement, and the bulletin lists the MR-J4-100B4-RJ as the alternative to the Mitsubishi MR-J3-100BS4. Changing to MR-J4 involves SSCNET III/H, a different controller setting, and a check of the motor, cables and safety wiring. A like-for-like replacement is the simpler option when only one amplifier has failed.
Quotation enquiries for Oman and the GCC
Seven Star LLC supplies the Mitsubishi MR-J3-100BS4 on request. Availability, condition and lead time are confirmed at quotation. Please send:
- The exact model from the amplifier rating plate, with the serial number.
- The quantity required.
- A clear photograph of the nameplate.
- The motor model, the motion controller, and whether the MR-J3-D05 or STO cables are also needed.
- A short description of the machine and axis.
Technical support with selection and cross-checking of the reference is provided, including a comparison with the MR-J4 alternative if a migration is being considered.
Datasheets & Documents
- Catalog Mitsubishi Safety Solutions Manufacturer Catalogue Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Mitsubishi Electric is the Japanese electrical and electronics manufacturer whose factory automation range includes MELSEC programmable controllers, GOT operator panels, MELSERVO servo systems, FR inverters and low-voltage switchgear. It was established on 15 January 1921, when the electrical machinery works of Mitsubishi Shipbuilding in Kobe became a separate company. Mitsubishi Electric Corporation is headquartered in Tokyo and listed on the Tokyo Stock Exchange.
Laboratories that run an NSX-2100 trace sulfur, nitrogen or chlorine analyzer usually know it as a Mitsubishi instrument. The nameplate reads Mitsubishi Chemical Analytech, a name later changed to Nittoseiko Analytech. Seven Star LLC lists the TN6RPC gas tube dryer set for this analyzer and sources NSX-2100 consumables for refinery and fuel-testing laboratories in Oman and the GCC.
The Mitsubishi listing also includes Mitsubishi Electric factory automation and drive products: MR-J3, MR-J5 and MR-JE servo amplifiers, GOT2000 and GOT SIMPLE HMI touch panels, FR-A800, FR-E800, FR-F800 and FR-CS80 FREQROL inverters, MELSEC iQ-F PLC modules, MELSEC A-series input and temperature modules with a memory cassette, and S-T magnetic contactors and TH-T thermal overload relays.
Mitsubishi company profile
| Established | 15 January 1921, from the electrical works of Mitsubishi Shipbuilding in Kobe, Japan |
|---|---|
| Headquarters | Tokyo, Japan |
| Ownership | Mitsubishi Electric Corporation, public company listed on the Tokyo Stock Exchange; a member of the Mitsubishi group of companies |
| Product families | MELSEC iQ-R, iQ-F and Q series PLCs, GOT2000 HMIs, MELSERVO MR-J5 and MR-JE servo amplifiers and motors, FR series inverters, S-T magnetic contactors and TH-T thermal overload relays, circuit breakers |
| Note | Laboratory analysers sold under the Mitsubishi Chemical Analytech name (now Nittoseiko Analytech) come from a different Mitsubishi company |
Mitsubishi NSX-2100 parts
The NSX-2100 was built with a horizontal or a vertical furnace, and one furnace can serve several detectors. The dryer set removes water from the combustion gas before it reaches the detector. Like the connection kits, it is a consumable, and its part code changes with the analyzer variant.
Mitsubishi products we list
Ordering NSX-2100 consumables: what we need
Send the part code, for example TN6RPC, together with the exact analyzer model shown on the nameplate (the letters after NSX-2100 indicate furnace type and detectors), the serial number and the detectors fitted. Some original part codes have been replaced by newer ones, so we check each code against the manufacturer's current parts list before quoting.
Facts checked against Mitsubishi Electric's published corporate profile, October 2026.
Browse Mitsubishi products by category: Gas Analyzer Accessories.
FAQ
Questions about the Mitsubishi MR-J3-100BS4 Servo Amplifier
Answers from our engineering team on installation, compatibility and integration.
01What supply does the Mitsubishi MR-J3-100BS4 need?
The main circuit needs three-phase 380 to 480 V AC at 50/60 Hz, and the control circuit needs single-phase 380 to 480 V AC. A 24 V DC interface supply is also required.
02What safety functions does the MR-J3-100BS4 provide?
It has built-in STO to IEC/EN 61800-5-2, rated PL d Category 3, SIL 2 and SIL CL 2. SS1 is available when the MR-J3-D05 safety logic unit is added.
03Which motors can be used with the MR-J3-100BS4?
The manual lists the HF-SP1024, HF-JP734 and HF-JP1034, and the HF-JP534 with the 400% maximum torque setting.
04Is the MR-J3-100BS4 still available from Mitsubishi?
Bulletin 17-06BE states that MR-J3 orders were accepted until 31 May 2019, and that repairs and parts were planned until 31 May 2026.
05What is the MR-J4 replacement for the MR-J3-100BS4?
Mitsubishi lists the MR-J4-100B4-RJ. A change to MR-J4 needs a review of the controller, cables and safety wiring.


















Reviews