ABB Glass Tube Variable Area Flowmeter FGM1190
Overview
The ABB FGM1190 is a general-purpose glass-tube variable area flowmeter for process flow measurement across a wide range of industries, sized well beyond the narrow purge-duty range of the Purgemaster FGM6100. Its flow range spans from 0.002 to 17600 l/h on water, covering the process measurement duty most plants actually need rather than the low-flow purge niche the FGM6100 serves, with maximum operating pressures up to 30 bar on the smallest tube sizes for liquid service.
With engineering support in Muscat, Seven Star LLC supplies the FGM1190 across Oman and the GCC, sizing the tube, float, and connection style to the customer’s actual process flow rate and fluid rather than defaulting to a single standard configuration, and supporting every order with manufacturer documentation.
Operating Principle
Fluid rising through the tapered borosilicate glass tube lifts a float until the annular gap between the float and the tube wall reaches equilibrium with the flow rate, giving a direct visual reading off the etched or attached scale without any electronic components required for local indication. Four scale types are available: a directly readable scale in flow units, a linearized percentage scale standard on 1/2 to 2 inch sizes, a DK/DS scale with corresponding flow-rate conversion tables, and a plain millimeter scale for applications where the customer applies their own conversion.
Because the float position is a direct mechanical response to flow, the reading remains valid during power loss and requires no transmitter for basic local monitoring, though electronic and mechanical output options are available where remote indication or alarming is also needed. A magnetically actuated reed-contact alarm signaling unit (type D55AX) can be fitted for high or low flow limit alarms, and single or dual-channel switching amplifiers are available in 115/230V AC or 24V DC power options for integration with a control or alarm system.
Engineering Design of the FGM1190
Connections are available from 1/4 inch to 2 inches threaded, DN10 to DN50 flanged, or SC15 to SC50 hygienic fittings to DIN 11851 – a considerably broader connection range than the FGM6100’s fixed 1/4-inch NPT/BSPP purge fitting, reflecting its role as a general process instrument rather than a dedicated purge indicator. Maximum operating pressure varies by tube size and service: liquid applications range from 30 bar on the smallest 1/8-1/4 inch sizes down to 7 bar on 2-inch meters, while gas service is rated lower across the same size range, and pressure limits reduce by 1% for every 2°C above 95°C on larger fluid sizes.
Float material options include stainless steel, glass, sapphire, Carboly, PVC, tantalum, Hastelloy, aluminum, and PTFE, with fittings in stainless steel, PVC, or PVDF, giving the FGM1190 the chemical compatibility range needed for corrosive process fluids. Accuracy is rated Class 1.6 to Class 6 depending on the specific tube diameter and float combination selected, and the meter operates across an ambient temperature range of -40°C to 60°C for liquid service, or -40°C to 40°C for gas service, with medium temperature further constrained by the fitting material and seal selection.
Key Features
- Wide process flow range: 0.002-17600 l/h on water.
- Threaded (1/4-2 in.), flanged (DN10-50), or hygienic (SC15-50, DIN 11851) connections.
- Maximum operating pressure up to 30 bar on liquid service (smallest sizes).
- Float materials from stainless steel and PTFE to sapphire and Hastelloy.
- Four scale reading options: direct flow units, linearized percentage, DK/DS, or millimeter.
- Optional reed-contact alarm signaling unit and switching amplifiers for remote monitoring.
- Accuracy Class 1.6 to Class 6 depending on configuration.
- No electronics required for reliable local indication during power loss.
Industrial Applications
The FGM1190 is used across system manufacturing, food and beverage, water treatment, and chemical processing plants in Muscat, Sohar, Salalah, and the wider GCC for general process flow indication where a robust, low-maintenance, visually-read instrument is preferred over an electronic transmitter. The hygienic DIN 11851 connection option in particular suits food, beverage, and pharmaceutical process lines across the region’s growing manufacturing sector.
Seven Star LLC, as a trusted ABB supplier, positions the FGM1190 for standard process flow duty and the Purgemaster FGM6100 (see related product) specifically for low-flow instrument and sample line purging, so customers across Oman’s industrial and utility sectors are matched to the correctly sized rotameter for their application and pressure class.
Technical Specifications
The table below summarizes the FGM1190’s core specifications as supplied by Seven Star LLC.
| Parameter | Specification |
|---|---|
| Model | ABB FGM1190 |
| Type | Glass tube variable area flowmeter |
| Flow range (water) | 0.002-17600 l/h |
| Connections | 1/4-2 in. threaded, DN10-50 flanged, SC15-50 hygienic |
| Max. pressure (liquid) | 30 bar (smallest sizes) to 7 bar (2 in.) |
| Ambient temperature | -40°C to 60°C (liquid); -40°C to 40°C (gas) |
| Accuracy | Class 1.6 to Class 6 |
| Tube material | Borosilicate glass |
| Float options | Stainless steel, glass, sapphire, Carboly, PVC, tantalum, Hastelloy, aluminum, PTFE |
| Accessories | Reed-contact alarm unit (D55AX), switching amplifiers, needle valves |
Request a Quote for ABB Glass Tube Variable Area Flowmeter FGM1190
Contact Seven Star LLC to submit a formal RFQ for the ABB FGM1190 glass tube variable area flowmeter, request the full technical datasheet, or check current availability and lead time across Oman and the GCC. Backed by genuine manufacturer documentation, Seven Star LLC’s instrumentation division can help specify the correct tube size, float material, and connection style for your process flow rate and fluid.
Related Products
- Datasheet ABB Glass Tube Variable Area Flowmeter FGM1190 Datasheet Download

Reviews