Brooks Instrument Sho-Rate 1358 High-Flow Glass Tube Flowmeter
Description
A simple glass tube flow indicator for 0.8 to 5.0 gpm of water
The Sho-Rate 1358 is a Brooks Instrument glass tube variable area flowmeter (rotameter) described in the datasheet as a cost-effective means of flow indication where accuracy requirements are not severe. It is the larger size 8 body in the Sho-Rate family and is stated to be ideal for flow rates from 0.8 to 5.0 gpm of water. Standard accuracy is 10 percent of full scale, with repeatability of 0.5 percent of full scale and a rangeability of 10 to 1.
The metering tube is heavy-wall, precision-bore borosilicate glass with interchangeable tubes and floats, and integral float stops prevent loss of the float during tube removal. The meter drops easily into a panel, and an integral needle control valve is available, as is a configuration to connect a flow controller at the inlet or outlet.
Technical specifications
| Parameter | Specification |
|---|---|
| Model | Sho-Rate 1358 (size 8, standard 10% accuracy) |
| Standard accuracy | +/-10% of full scale |
| Repeatability | 0.5% of full scale |
| Rangeability | 10:1 |
| Pressure and temperature | 200 psig at 33 to 250 F (1 to 121 C); 100 psig at 33 to 250 F with CRN certification |
| Low temperature note | Fluid below 32 F (0 C) causes frosting of the glass tube |
| Maximum flow, water | 0.8, 1.5, 2.5, 3.5 or 5.0 gpm by float (8-RV-8, 8-RJ-10, 8-RJ-23, 8-RJ-30, 8-RJ-39) |
| Maximum flow, air | 3.4, 6.0, 12.0 or 15.0 scfm at 14.7 psia and 70 F |
| Pressure drop without valve, water | 12.6 to 172 inches W.C., rising with float size |
| Metering tube | Borosilicate glass, tube R-8M-75-1, 75 mm nominal scale fused on tube |
| Float and float stops | 316 stainless steel float; stainless steel float stops |
| Tube packing | Neoprene (brass meters), Viton-A (stainless steel meters), optional EPM |
| O-rings | Buna-N (brass meters), Viton-A (stainless steel meters), optional EPM |
| Side plates and window | Black anodised aluminium; scratch-resistant UV-stabilised polycarbonate window; milk-white polycarbonate back cover |
| End fittings | Chrome-plated brass or 316 stainless steel |
| Connections | Standard horizontal female 3/8 inch NPT adaptors; other options by model code |
| Scale | Direct read on tube in gpm of water or scfm of air; optional special decal or detachable metal scale |
| PED status | Sound engineering practice (SEP) per Directive 97/23/EC |
Selecting the Sho-Rate 1358 configuration
The sample model code in the datasheet reads 1358F 1 C 2 D C 2 B 1 A. After the base code 1358F, the code selects the tube (standard, CRN option or no tube), one of five stainless steel floats, the scale type, scale inscription (none, millimetre, SCFM air, GPM liquid at specific gravity 1.0 and 1.0 cP, or special inscriptions), tube packing and O-ring material, fitting and adapter material with 3/8 inch NPT connection (brass or 316 stainless, with or without locknut), valve configuration, and port orientation. Valve choices are none, a stainless steel or brass needle valve on inlet or outlet, or an adaptation to mount an 8810, 8910 or 8830 flow controller, which must be a second line item on the order.
What to confirm before ordering
Please send the fluid and its density and viscosity, the flow range and unit, pressure and temperature, the connection and port orientation, whether a valve or flow controller is needed and whether CRN is required. The meter is a low-accuracy indicator, so for tighter measurement the Sho-Rate 1355G or a metal-tube meter should be compared. The datasheet is short, and this page therefore carries only what it states.
Documents and quotation
The manufacturer datasheet (5 pages) is attached to this page as a download. For a quotation, send the full model code and the process data to Seven Star LLC in Muscat; browse more instruments in the Flowmeters category. We supply this item as an independent supplier, so please confirm availability and delivery with us.
Datasheets & Documents
- Datasheet Brooks Instrument Sho-Rate Model 1358 datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Brooks Instrument makes mass flow controllers, flowmeters and pressure and vacuum instruments for gases and liquids. The industrial chemist Stephen A. Brooks started the business in 1946 as the Brooks Rotameter Company near Philadelphia, building variable area flowmeters. After many years as part of Emerson, Brooks was sold to American Industrial Partners at the end of 2007 and has been a division of Illinois Tool Works (ITW) since January 2012. It is headquartered in Hatfield, Pennsylvania.
Seven Star LLC is an independent supplier listing Brooks Instrument thermal and Coriolis mass flow controllers and variable area flowmeters for buyers in Oman and the GCC. Instruments are matched from the model code and the gas, range and calibration data on the label.
Brooks Instrument company profile
| Origin | Founded in 1946 by Stephen A. Brooks as the Brooks Rotameter Company, Lansdale, Pennsylvania |
|---|---|
| Headquarters | Hatfield, Pennsylvania, USA |
| Ownership | Emerson division until 31 December 2007, then American Industrial Partners; part of ITW since January 2012 |
| Product families | Thermal, pressure-based and Coriolis mass flow controllers and meters, metal tube and glass tube variable area flowmeters, pressure and vacuum products |
| Typical duty | Precise gas and liquid flow control in process, laboratory, analyser, fuel cell and semiconductor applications |
Milestones
- 1946: Stephen A. Brooks founds the Brooks Rotameter Company in Lansdale, Pennsylvania.
- 2007: After years as an Emerson division, Brooks is sold to American Industrial Partners on 31 December.
- 2012: Brooks Instrument becomes part of ITW in January.
Brooks mass flow controllers and flowmeters
| Series | Type | Typical use |
|---|---|---|
| SLA5800, SLAMf | Thermal mass flow controllers and meters | Gas flow control in process and analytical systems; SLAMf with an IP66 enclosure for harsh or outdoor locations |
| 5800E | Analog thermal mass flow controller | Installed base in older systems; often replaced with the SLA5800 series |
| Quantim QMC | Coriolis mass flow controller | Low-flow liquid and gas control independent of fluid properties |
| GF40, GF80, GF100, GP200 | Metal-sealed thermal and pressure-based mass flow controllers | High-purity and semiconductor gas delivery; MultiFlo allows gas and range changes without recalibration |
| MT3750C, MT3809G | Metal tube variable area flowmeters | Purge, chemical injection and utility flows at higher pressure and temperature, with optional transmitter and alarms |
| GT1600, Sho-Rate 1250/1255 | Glass tube variable area flowmeters | Visual flow indication on purge, sample and laboratory lines |
Where Brooks instruments are used
Brooks mass flow controllers dose gases in analyser systems, catalyst and pilot plant testing, gas blending, burner and combustion control, fuel cell test stands and semiconductor tools. Variable area flowmeters are widely used on purge gas, seal flush, sample and chemical injection lines in oil and gas, refining and petrochemical plants, where a simple local indication without external power is preferred.
Ordering Brooks instruments: what we need
Send the full model code and serial number from the label. Mass flow controllers are calibrated for a specific gas and full-scale flow, so state the gas or gas mixture, flow range, inlet and outlet pressure, temperature, process connection, seal material, signal (analog, RS-485, DeviceNet, EtherNet/IP or other) and any hazardous-area requirement. For variable area meters add the fluid, density, viscosity, flow range, connection size, materials and whether alarms or a 4-20 mA output are needed.
Facts checked against Brooks Instrument company information and product data, October 2026.
Browse Brooks Instrument products by category: Flowmeters.
Related products
Frequently Asked Questions
0.8 to 5.0 gpm of water, or up to 15 scfm of air, depending on the float.
Standard accuracy is 10 percent of full scale with 0.5 percent repeatability.
200 psig at 33 to 250 F, or 100 psig with CRN certification.
Yes. A stainless steel or brass needle valve can be fitted on the inlet or outlet.
Horizontal female 3/8 inch NPT threaded adaptors.